Risk-informed optimization of the tuned mass-damper-inerter (TMDI) for the seismic protection of multi-storey building structures
Open accessThe DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
Abstract
The tuned mass-damper-inerter (TMDI) is a recently proposed passive vibration suppression device that couples the classical tuned mass-damper (TMD), comprising a secondary mass attached to the structure via a spring and dashpot, with an inerter. The latter is a two-terminal mechanical device developing a resisting force proportional to the relative acceleration of its terminals by the “inertance” constant. In a number of previous studies, optimally tuned TMDIs have been shown to outperform TMDs in mitigating earthquake-induced vibrations in building structures for the same pre-specified secondary mass. TMDI design in these studies involved simplified modeling assumptions, such as adopting a single performance objective and/or modeling seismic excitation as stationary stochastic process. This paper extends these efforts by examining a risk-informed TMDI optimization, adopting multiple objectives and using response history analysis and probabilistic life-cycle criteria to quantify performance. The first performance criterion, representing overall direct benefits, is the life-cycle cost of the system, composed of the upfront TMDI cost and the anticipated seismic losses over the lifetime of the structure. The second performance criterion, introducing risk-aversion attitudes into the design process, is the repair cost with a specific return period (i.e., probability of exceedance over the lifetime of the structure). The third performance criterion, accounting for practical constraints associated with the size of the inerter and its connection to the structure, is the inerter force with a specific return period. A particular variant of the design problem is also examined by combining the first and third performance criteria/objectives. A case study involving a 21-storey building constructed in Santiago, Chile shows that optimal TMDI configurations can accomplish simultaneous reduction of life-cycle and repair costs. However, these cost reductions come at the expense of increased inerter forces. It is further shown that connecting the inerter to lower floors provides considerable benefits across all examined performance criteria as the inerter is engaged in a more efficient way for the same inerter coefficient and attached mass ratios.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Study of Cross-Validation and Bootstrap for Accuracy Estimation and Model Selection
Kohavi, R. (1995) · Zenodo · doi:10.5281/zenodo.19712698 · Cited by 10,909
Synthesis of mechanical networks: the inerter
Smith, M. C. (2002) · IEEE Transactions on Automatic Control · doi:10.1109/tac.2002.803532 · Cited by 1,828
Marian, L., & Giaralis, A. (2014) · Probabilistic Engineering Mechanics · doi:10.1016/j.probengmech.2014.03.007 · Cited by 828 · cited 6×
“In a number of seismic application studies [17, 22, 26, 27], the TMDI was shown to outperform the TMD, especially for relatively small secondary attached mass.”
InfluentialSelf-citationUsing an inerter‐based device for structural vibration suppression
Lazar, I. F., Neild, S. A., & Wagg, D. J. (2014) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2390 · Cited by 799
Seismic control of single‐degree‐of‐freedom structure using tuned viscous mass damper
Ikago, K., Saito, K., & Inoue, N. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1138 · Cited by 782
Optimal tuned mass damper for seismic applications and practical design formulas
Hoang, N., Fujino, Y., & Warnitchai, P. (2008) · Engineering Structures · doi:10.1016/j.engstruct.2007.05.007 · Cited by 382
Optimal design and performance evaluation of systems with Tuned Mass Damper Inerter (TMDI)
Pietrosanti, D., De Angelis, M., & Basili, M. (2017) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.2861 · Cited by 349
Wind-Induced Vibration Mitigation in Tall Buildings Using the Tuned Mass-Damper-Inerter
Giaralis, A., & Petrini, F. (2017) · Journal of Structural Engineering · doi:10.1061/(asce)st.1943-541x.0001863 · Cited by 330
Self-citationDynamic response and optimal design of structures with large mass ratio TMD
De Angelis, M., Perno, S., & Reggio, A. (2012) · Earthquake Engineering & Structural Dynamics · doi:10.1002/eqe.1117 · Cited by 239
Mass dampers and their optimal designs for building vibration control
Chang, C. C. (1999) · Engineering Structures · doi:10.1016/s0141-0296(97)00213-7 · Cited by 177
Research works printed but not linked: 39
- Kareem A. The next generation of tuned liquid dampers. Proc, First World Conference on Structural Control1994. p. 19–28.
- Tait, 2007, Effectiveness of a 2D TLD and its numerical modeling, J Struct Eng, 133, 251, 10.1061/(ASCE)0733-9445(2007)133:2(251) · doi:10.1061/(asce)0733-9445(2007)133:2(251
- Feng, 1995, Vibration control of tall buildings using mega subconfiguration, J Eng Mech, 121, 1082, 10.1061/(ASCE)0733-9399(1995)121:10(1082) · doi:10.1061/(asce)0733-9399(1995)121:10(1082 · Paper page
- Matta, 2011, Performance of tuned mass dampers against near-field earthquakes, Struct Eng Mech, 39, 621, 10.12989/sem.2011.39.5.621 · DOI · Paper page
- Reggio, 2015, Optimal energy-based seismic design of non-conventional Tuned Mass Damper (TMD) implemented via inter-story isolation, Earthq Eng Struct Dyn, 44, 1623, 10.1002/eqe.2548 · DOI · Paper page
- Lavan, 2017, Multi-objective optimal design of tuned mass dampers, Struct Control Health Monitor, 24, 10.1002/stc.2008 · DOI
- Ruiz, 2015, Life-cycle based design of mass dampers for the Chilean region and its application for the evaluation of the effectiveness of tuned liquid dampers with floating roof, Bull Earthq Eng, 14, 943, 10.1007/s10518-015-9860-9 · DOI
- Taflanidis, 2009, Life-cycle cost optimal design of passive dissipative devices, Struct Saf, 31, 508, 10.1016/j.strusafe.2009.06.010 · DOI
- Shin, 2014, Minimum failure cost-based energy dissipation system designs for buildings in three seismic regions Part II: Application to viscous dampers, Eng Struct
- Pollini, 2016, Towards realistic minimum-cost optimization of viscous fluid dampers for seismic retrofitting, Bull Earthq Eng, 14, 971, 10.1007/s10518-015-9844-9 · DOI
- Marian L, Giaralis A. Optimal design of inerter devices combined with TMDs for vibration control of buildings exposed to stochastic seismic excitations. In: 11th International Conference on Structural Safety and Reliability. New York, US2013. p. 1025–32. · DOI
- Watanabe Y, Ikago K, Inoue N, Kida H, Nakaminami S, Tanaka H et al. Full-scale dynamic tests and analytical verification of a force-restricted tuned viscous mass damper. In: 15th World Conference on Earthquake Engineering. Lisbon, Portugal 2012.
- Nakamura, 2014, Seismic response control using electromagnetic inertial mass dampers, Earthq Eng Struct Dyn, 43, 507, 10.1002/eqe.2355 · DOI · Paper page
- Giaralis, 2018, Optimal tuned mass-damper-inerter (TMDI) design for seismically excited MDOF structures with model uncertainties based on reliability criteria, Struct Control Health Monitor, 25, e2082, 10.1002/stc.2082 · DOI · Paper page
- Hwang, 2007, Rotational inertia dampers with toggle bracing for vibration control of a building structure, Eng Struct, 29, 1201, 10.1016/j.engstruct.2006.08.005 · DOI · Paper page
- Giaralis A, Marian L. Use of inerter devices for weight reduction of tuned mass-dampers for seismic protection of multi-story building: the Tuned Mass-Damper-Interter (TMDI). SPIE 9799, Active and Passive Smart Structures and Integrated Systems Las Vegas, Nevada 2016. p. doi: 10.1117/12.2219324. · DOI
- Ikago, 2012, Modal response characteristics of a multiple-degree-of-freedom structure incorporated with tuned viscous mass dampers, J Asian Architect Build Eng, 11, 375, 10.3130/jaabe.11.375 · DOI
- Krenk, 2016, Tuned resonant mass or inerter-based absorbers: unified calibration with quasi-dynamic flexibility and inertia correction, Proc Royal Soc A, 472, 20150718, 10.1098/rspa.2015.0718 · DOI · Paper page
- Wen, 2016, Design and evaluation of tuned inerter-based dampers for the seismic control of MDOF structures, J Struct Eng, 143, 04016207, 10.1061/(ASCE)ST.1943-541X.0001680 · DOI · Paper page
- Zhang, 2017, Optimal configurations for a linear vibration suppression device in a multi-storey building, Struct Control Health Monitor, 24, 10.1002/stc.1887 · DOI · Paper page
- Takewaki, 2012, Fundamental mechanism of earthquake response reduction in building structures with inertial dampers, Struct Control Health Monitor, 19, 590, 10.1002/stc.457 · DOI · Paper page
- Boroschek R, Contreras V. Strong ground motion form the 2010 Mw 8.8 Maule Chile earthquake and attenuation relations for Chilean subduction zone interface earthquakes. In: International Symposium on Engineering Lessons Learned from the 2011 Great East Japan earthquake. Tokyo, Japan 2012. · doi:10.1193/1.4000045
- Gidaris, 2018, Multiobjective design of supplemental seismic protective devices utilizing lifecycle performance criteria, J Struct Eng, ASCE, 144, 04017225, 10.1061/(ASCE)ST.1943-541X.0001969 · DOI
- Cha, 2014, Seismic risk mitigation of building structures: The role of risk aversion, Struct Saf, 40, 11, 10.1016/j.strusafe.2012.06.004 · DOI
- Haukaas, 2008, Unified reliability and design optimization for earthquake engineering, Probab Eng Mech, 23, 471, 10.1016/j.probengmech.2007.10.008 · doi:10.1016/j.probengmech.2007.10.008
- Massone, 2012, Seismic design and construction practices for RC structural wall buildings, Earthq Spectra, 28, S245, 10.1193/1.4000046 · doi:10.1193/1.4000046
- Marian, 2017, The tuned mass-damper-inerter for harmonic vibrations suppression, attached mass reduction, and energy harvesting, Smart Struct Syst
- Goulet, 2007, Evaluation of the seismic performance of code-conforming reinforced-concrete frame building-From seismic hazard to collapse safety and economic losses, Earthq Eng Struct Dyn, 36, 1973, 10.1002/eqe.694 · DOI · Paper page
- Porter, 2001, Assembly-based vulnerability of buildings and its use in performance evaluation, Earthq Spectra, 18, 291, 10.1193/1.1586176 · doi:10.1193/1.1586176
- Gidaris, 2015, Performance assessment and optimization of fluid viscous dampers through life-cycle cost criteria and comparison to alternative design approaches, Bull Earthq Eng, 13, 1003, 10.1007/s10518-014-9646-5 · DOI
- Zemp, 2011, Tall building vibration control using a TM-MR damper assembly: Experimental results and implementation, Earthq Eng Struct Dyn, 40, 257, 10.1002/eqe.1021 · doi:10.1002/eqe.1021
- Leyton, 2009, Preliminary re-evaluation of probabilistic seismic hazard assessment in Chile: from Arica to Taitao Peninsula, Adv Geosci, 22, 147, 10.5194/adgeo-22-147-2009 · DOI
- Ordaz, 2014, Probabilistic seismic hazard assessment at global level, Int J Disaster Risk Reduct, 10, 419, 10.1016/j.ijdrr.2014.05.004 · doi:10.1016/j.ijdrr.2014.05.004
- Lamprou, 2013, Life-cycle seismic loss estimation and global sensitivity analysis based on stochastic ground motion modeling, Eng Struct, 54, 192, 10.1016/j.engstruct.2013.04.001 · DOI
- Franchin, 2018, Improved risk-targeted performance-based seismic design of reinforced concrete frame structures, Earthq Eng Struct Dyn, 47, 49, 10.1002/eqe.2936 · doi:10.1002/eqe.2936
- Tse, 2012, Performance and cost evaluation of a smart tuned mass damper for suppressing wind-induced lateral-torsional motion of tall structures, J Struct Eng, 138, 514, 10.1061/(ASCE)ST.1943-541X.0000486 · DOI · Paper page
- Saitua, 2018, Optimization of height-wise dampers distribution considering practical design issues, Eng Struct, 173, 768, 10.1016/j.engstruct.2018.04.008 · doi:10.1016/j.engstruct.2018.04.008
- Vetter, 2016, Tuning of stochastic ground motion models for compatibility with ground motion prediction equations, Earthq Eng Struct Dyn, 45, 893, 10.1002/eqe.2690 · doi:10.1002/eqe.2690
- Jalayer, 2008, Effects of two alternative representations of ground-motion uncertainty in probabilistic seismic demand assessment of structures, Earthq Eng Struct Dyn, 37, 61, 10.1002/eqe.745 · doi:10.1002/eqe.745
Cited by
Inerter-based structural vibration control: A state-of-the-art review
Ma, R., Bi, K., & Hao, H. (2021) · Engineering Structures · doi:10.1016/j.engstruct.2021.112655 · Cited by 445
Innovations in earthquake risk reduction for resilience: Recent advances and challenges
Freddi, F., Galasso, C., Cremen, G., Dall’Asta, A., Di Sarno, L., Giaralis, A., Gutiérrez-Urzúa, F., Málaga-Chuquitaype, C., Mitoulis, S. A., Petrone, C., et al. (2021) · International Journal of Disaster Risk Reduction · doi:10.1016/j.ijdrr.2021.102267 · Cited by 224
“This issue has been partially addressed in the literature by allowing DVAs to span more than one floor, as seen in Figure 15(b) [207,227], by equipping inerters with one-way clutches and twin flywheels [232,238] and by considering more complex inerter-based DVA layouts than those in Figure 14(a) [239].”
MethodSelf-citationElimination of multimode resonances of composite plate by inertial nonlinear energy sinks
Chen, H.-Y., Mao, X.-Y., Ding, H., & Chen, L.-Q. (2020) · Mechanical Systems and Signal Processing · doi:10.1016/j.ymssp.2019.106383 · Cited by 147
Tuned mass damper inerter for seismic control of multi-story buildings: Ten years since inception
Konar, T., & Ghosh, A. (. (2024) · Structures · doi:10.1016/j.istruc.2024.106459 · Cited by 57
Kang, X., Huang, Q., Wu, Z., Tang, J., Jiang, X., & Lei, S. (2024) · Computer Modeling in Engineering & Sciences · doi:10.32604/cmes.2023.043936 · Cited by 22
Metadata
- Authors
- Ruiz, R., Taflanidis, A. A., Giaralis, A., & Lopez-Garcia, D.
- Venue
- Engineering Structures
- Publisher
- Elsevier BV
- Published
- 2018-12
- Volume
- 177
- Pages
- 836-850
- ISSN
- 0141-0296 (ISSN-L)
- OpenAlex
- W2898484079
- Cited by
- 133
- References
- 13
- FWCI
- 8.08
- Type
- journal article
- Language
- en
- Open access
- bronze
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- Funders
- EPSRC (EP/M017621/1)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.