Indoor air quality guidelines from across the world: An appraisal considering energy saving, health, productivity, and comfort
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
Buildings are constructed and operated to satisfy human needs and improve quality of life. Good indoor air quality (IAQ) and thermal comfort are prerequisites for human health and well-being. For their provision, buildings often rely on heating, ventilation, and air conditioning (HVAC) systems, which may lead to higher energy consumption. This directly impacts energy efficiency goals and the linked climate change considerations. The balance between energy use, optimum IAQ and thermal comfort calls for scientifically solid and well-established limit values for exposures experienced by building occupants in indoor spaces, including homes, schools, and offices. The present paper aims to appraise limit values for selected indoor pollutants reported in the scientific literature, and to present how they are handled in international and national guidelines and standards. The pollutants include carbon dioxide (CO2), formaldehyde (CH2O), particulate matter (PM), nitrogen dioxide (NO2), carbon monoxide (CO), and radon (Rn). Furthermore, acknowledging the particularly strong impact on energy use from HVAC, ventilation, indoor temperature (T), and relative humidity (RH) are also included, as they relate to both thermal comfort and the possibilities to avoid moisture related problems, such as mould growth and proliferation of house dust mites. Examples of national regulations for these parameters are presented, both in relation to human requirements in buildings and considering aspects related to energy saving. The work is based on the Indoor Environmental Quality (IEQ) guidelines database, which spans across countries and institutions, and aids in taking steps in the direction towards a more uniform guidance for values of indoor parameters. The database is coordinated by the Scientific and Technical Committee (STC) 34, as part of ISIAQ, the International Society of Indoor Air Quality and Climate.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thermal comfort: Analysis and applications in environmental engineering
(1972) · Applied Ergonomics · doi:10.1016/s0003-6870(72)80074-7 · Cited by 4,451
IPCC--Intergovernmental Panel on Climate Change
(2008) · Choice Reviews Online · doi:10.5860/choice.45-5008 · Cited by 3,306
IARC (International Agency for Research on Cancer)
Toporcov, T. N., & Filho, V. W. (2018) · Cited by 1,178
Li, Y., Leung, G. M., Tang, J. W., Yang, X., Chao, C. Y. H., Lin, J. Z., Lu, J. W., Nielsen, P. V., Niu, J., Qian, H., et al. (2007) · Indoor Air · doi:10.1111/j.1600-0668.2006.00445.x · Cited by 1,055
A review of human thermal comfort in the built environment
Rupp, R. F., Vásquez, N. G., & Lamberts, R. (2015) · Energy and Buildings · doi:10.1016/j.enbuild.2015.07.047 · Cited by 907
Rudnick, S. N., & Milton, D. K. (2003) · Indoor Air · doi:10.1034/j.1600-0668.2003.00189.x · Cited by 624
Fuel poverty and human health: A review of recent evidence
Liddell, C., & Morris, C. (2010) · Energy Policy · doi:10.1016/j.enpol.2010.01.037 · Cited by 618
Hoyt, T., Arens, E., & Zhang, H. (2015) · Building and Environment · doi:10.1016/j.buildenv.2014.09.010 · Cited by 607
Huangfu, P., & Atkinson, R. (2020) · Environment International · doi:10.1016/j.envint.2020.105998 · Cited by 522
Monn, C. (2001) · Atmospheric Environment · doi:10.1016/s1352-2310(00)00330-7 · Cited by 514
Environmental Burden of Disease in Europe: Assessing Nine Risk Factors in Six Countries
Hänninen, O., Knol, A. B., Jantunen, M., Lim, T.-A., Conrad, A., Rappolder, M., Carrer, P., Fanetti, A.-C., Kim, R., Buekers, J., et al. (2014) · Environmental Health Perspectives · doi:10.1289/ehp.1206154 · Cited by 474
Outdoor-indoor air pollution in urban environment: challenges and opportunity
Leung, D. Y. C. (2015) · Frontiers in Environmental Science · doi:10.3389/fenvs.2014.00069 · Cited by 401
Kumar, P., Singh, A. B., Arora, T., Singh, S., & Singh, R. (2023) · Science of The Total Environment · doi:10.1016/j.scitotenv.2023.162163 · Cited by 380
Self-citationWolkoff, P., Wilkins, C. K., Clausen, P. A., & Nielsen, G. D. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00393.x · Cited by 348
Indoor secondary pollutants from cleaning product and air freshener use in the presence of ozone
Singer, B. C., Coleman, B. K., Destaillats, H., Hodgson, A. T., Lunden, M. M., Weschler, C. J., & Nazaroff, W. W. (2006) · Atmospheric Environment · doi:10.1016/j.atmosenv.2006.06.005 · Cited by 330
Impact of climate change on the domestic indoor environment and associated health risks in the UK
Vardoulakis, S., Dimitroulopoulou, C., Thornes, J., Lai, K.-M., Taylor, J., Myers, I., Heaviside, C., Mavrogianni, A., Shrubsole, C., Chalabi, Z., et al. (2015) · Environment International · doi:10.1016/j.envint.2015.09.010 · Cited by 308
Thermal environment and sleep quality: A review
Lan, L., Tsuzuki, K., Liu, Y. F., & Lian, Z. W. (2017) · Energy and Buildings · doi:10.1016/j.enbuild.2017.05.043 · Cited by 285
Wolkoff, P., Azuma, K., & Carrer, P. (2021) · International Journal of Hygiene and Environmental Health · doi:10.1016/j.ijheh.2021.113709 · Cited by 279
The dichotomy of relative humidity on indoor air quality
Wolkoff, P., & Kjærgaard, S. K. (2007) · Environment International · doi:10.1016/j.envint.2007.04.004 · Cited by 260
Heart rate variability at different thermal comfort levels
Liu, W., Lian, Z., & Liu, Y. (2008) · European Journal of Applied Physiology · doi:10.1007/s00421-008-0718-6 · Cited by 256
Persily, A. (2015) · Building and Environment · doi:10.1016/j.buildenv.2015.02.026 · Cited by 249
Guo, M., Xu, P., Xiao, T., He, R., Dai, M., & Miller, S. L. (2021) · Building and Environment · doi:10.1016/j.buildenv.2020.107368 · Cited by 231
Personal comfort systems: A review on comfort, energy, and economics
Rawal, R., Schweiker, M., Kazanci, O. B., Vardhan, V., Jin, Q., & Duanmu, L. (2020) · Energy and Buildings · doi:10.1016/j.enbuild.2020.109858 · Cited by 231
Halios, C. H., Landeg-Cox, C., Lowther, S. D., Middleton, A., Marczylo, T., & Dimitroulopoulou, S. (2022) · Science of The Total Environment · doi:10.1016/j.scitotenv.2022.156201 · Cited by 227
Self-citationEffects of moderate thermal environments on cognitive performance: A multidisciplinary review
Zhang, F., de Dear, R., & Hancock, P. (2019) · Applied Energy · doi:10.1016/j.apenergy.2018.12.005 · Cited by 217
Hodgson, A. T., Beal, D., & McIlvaine, J. E. R. (2002) · Indoor Air · doi:10.1034/j.1600-0668.2002.01129.x · Cited by 213
Volatile Organic Compounds Sources, Measurements, Emissions, and the Impact on Indoor Air Quality
Wolkoff, P. (1995) · Indoor Air · doi:10.1111/j.1600-0668.1995.tb00017.x · Cited by 210
Indoor CO 2 concentrations and cognitive function: A critical review
Du, B., Tandoc, M. C., Mack, M. L., & Siegel, J. A. (2020) · Indoor Air · doi:10.1111/ina.12706 · Cited by 190
Yao, Y., Lian, Z., Liu, W., Jiang, C., Liu, Y., & Lu, H. (2009) · Indoor Air · doi:10.1111/j.1600-0668.2008.00565.x · Cited by 174
Low Level Carbon Dioxide Indoors—A Pollution Indicator or a Pollutant? A Health-Based Perspective
Lowther, S. D., Dimitroulopoulou, S., Foxall, K., Shrubsole, C., Cheek, E., Gadeberg, B., & Sepai, O. (2021) · Environments · doi:10.3390/environments8110125 · Cited by 166
Self-citationThe impact of household energy efficiency measures on health: A meta-analysis
Maidment, C., Jones, C. R., Webb, T. L., Hathway, E. A., & Gilbertson, J. (2013) · Energy Policy · doi:10.1016/j.enpol.2013.10.054 · Cited by 157
Indoor air quality in the Swedish housing stock and its dependence on building characteristics
Langer, S., & Bekö, G. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.07.013 · Cited by 146
Cost benefit analysis of the night-time ventilative cooling in office building
Seppänen, O., Fisk, W. J., & Faulkner, D. M. (2003) · University of North Texas Digital Library (University of North Texas) · Cited by 129
Toyinbo, O., Shaughnessy, R. J., Turunen, M., Putus, T., Metsämuuronen, J., Kurnitski, J., & Haverinen‐Shaughnessy, U. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.04.030 · Cited by 127
Self-citationVillanueva, F., Tapia, A., Lara, S., & Amo‐Salas, M. (2017) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2017.11.274 · Cited by 124
Radon interventions around the globe: A systematic review
Khan, S. M., Gomes, J., & Krewski, D. R. (2019) · Heliyon · doi:10.1016/j.heliyon.2019.e01737 · Cited by 113
Ten questions concerning thermal environment and sleep quality
Lan, L., & Lian, Z. (2016) · Building and Environment · doi:10.1016/j.buildenv.2016.01.017 · Cited by 109
Wang, F., Meng, D., Li, X., & Tan, J. (2016) · Environmental Pollution · doi:10.1016/j.envpol.2016.05.023 · Cited by 104
Collaborators, G. 2. O. C. R. R. F. (2020) · Occupational and Environmental Medicine · doi:10.1136/oemed-2019-106013 · Cited by 100
Romero, M. T. B., Dudzińska, M. R., Torkmahalleh, M. A., Barros, N. A., Coggins, M. A., Rüzgar, D. G., Kildsgaard, I., Naseri, M., Li, R., Saffell, J. R., et al. (2022) · Indoor Air · doi:10.1111/ina.13144 · Cited by 89
Self-citationGunschera, J., Menteşe, S., Salthammer, T., & Andersen, J. R. (2013) · Building and Environment · doi:10.1016/j.buildenv.2013.03.001 · Cited by 85
Is mixed-mode ventilation a comfortable low-energy solution? A literature review
Kim, J., & de Dear, R. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108215 · Cited by 84
Shared Air: A Renewed Focus on Ventilation for the Prevention of Tuberculosis Transmission
Richardson, E. T., Morrow, C. D., Kalil, D. B., Bekker, L., & Wood, R. (2014) · PLoS ONE · doi:10.1371/journal.pone.0096334 · Cited by 83
On the Development of Health-Based Ventilation Guidelines: Principles and Framework
Carrer, P., Fernandes, E. D. O., Santos, H., Hänninen, O., Kephalopoulos, S., & Wargocki, P. L. (2018) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph15071360 · Cited by 82
Blondel, A., & Plaisance, H. (2010) · Building and Environment · doi:10.1016/j.buildenv.2010.12.011 · Cited by 81
Derby, M. M., Hamehkasi, M., Eckels, S. J., Hwang, G. M., Jones, B., Maghirang, R. G., & Shulan, D. J. (2016) · Science and Technology for the Built Environment · doi:10.1080/23744731.2016.1206430 · Cited by 80
Lam, J., Koustas, E., Sutton, P., Padula, A. M., Cabana, M. D., Vesterinen, H. M., Griffiths, C. W., Dickie, M., Daniels, N., Whitaker, E. M., et al. (2021) · PLoS ONE · doi:10.1371/journal.pone.0248258 · Cited by 73
Ielpo, P., Mangia, C., Marra, G. P., Comite, V., Rizza, U., Uricchio, V. F., & Fermo, P. (2018) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2018.08.159 · Cited by 67
Vouriot, C., Burridge, H. C., Noakes, C. J., & Linden, P. F. (2021) · Indoor Air · doi:10.1111/ina.12818 · Cited by 66
The future of IEQ in green building certifications
Licina, D., Wargocki, P. L., Pyke, C. R., & Altomonte, S. (2021) · Buildings and Cities · doi:10.5334/bc.148 · Cited by 58
Khan, S. M., Pearson, D. D., Rönnqvist, T., Nielsen, M. E., Taron, J. M., & Goodarzi, A. A. (2021) · Scientific Reports · doi:10.1038/s41598-021-96928-x · Cited by 52
Vu, T. V., Stewart, G. B., Kitwiroon, N., Lim, S., Barratt, B., Kelly, F. J., Thompson, R., Smith, R. B., Toledano, M. B., & Beevers, S. D. (2022) · Building and Environment · doi:10.1016/j.buildenv.2022.109359 · Cited by 51
Wang, C., Wang, J., & Norbäck, D. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph19127393 · Cited by 48
Zhang, T., Yin, S., & Wang, S. (2011) · Building and Environment · doi:10.1016/j.buildenv.2011.03.014 · Cited by 46
Milhem, S. A., Verrièle, M., Nicolas, M., & Thévenet, F. (2020) · Atmospheric Environment · doi:10.1016/j.atmosenv.2020.118060 · Cited by 40
Building and indoor environmental quality assessment of Nigerian primary schools: A pilot study
Toyinbo, O., Phipatanakul, W., Shaughnessy, R. J., & Haverinen‐Shaughnessy, U. (2019) · Indoor Air · doi:10.1111/ina.12547 · Cited by 37
Self-citationLim, S. M., Choi, J. W., Hong, M. H., Jung, D., Lee, C. Y., Park, S. Y., Shim, H. S., Sheen, S. S., Kwak, K. I., Kang, D. R., et al. (2019) · Lung Cancer · doi:10.1016/j.lungcan.2019.04.002 · Cited by 37
Taylor, J., Yates, T., Mthethwa, M., Tanser, F. C., Abubakar, I. I., & Altamirano, H. (2016) · The International Journal of Tuberculosis and Lung Disease · doi:10.5588/ijtld.16.0085 · Cited by 28
Naghizadeh, A., Sharifzadeh, G., Tabatabaei, F., Afzali, A., Yari, A. R., Geravandi, S., & Mohammadi, M. J. (2019) · Environmental Geochemistry and Health · doi:10.1007/s10653-018-0226-5 · Cited by 24
Nathavitharana, R. R., Mishra, H. K., Sullivan, A., Hurwitz, S., Lederer, P. A., Meintjes, J., Nardell, E. A., & Theron, G. (2022) · Clinical Infectious Diseases · doi:10.1093/cid/ciac183 · Cited by 19
Indoor environmental quality, energy efficiency and thermal comfort in the retrofitting of housing
Ortiz, M. A., & Bluyssen, P. M. (2022) · Routledge eBooks · doi:10.4324/9781003244929-32 · Cited by 8
Hunt, D., Suibhne, N. M., Dimache, L., McHugh, D., & Lohan, J. (2020) · Renewable and Sustainable Energy Reviews · doi:10.1016/j.rser.2020.110327 · Cited by 7
Metadata
- Authors
- Dimitroulopoulou, S., Dudzińska, M. R., Gunnarsen, L., Hägerhed, L., Maula, H., Singh, R., Toyinbo, O., & Haverinen-Shaughnessy, U.
- Venue
- Environment International
- Publisher
- Elsevier BV
- Published
- 2023-08
- Volume
- 178
- Pages
- 108127
- ISSN
- 0160-4120 (ISSN-L)
- OpenAlex
- W4385411818
- Cited by
- 226
- References
- 62
- FWCI
- 23.04
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.