The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
Prostate Magnetic Resonance Imaging Interpretation Varies Substantially Across Radiologists
Open accessAbstract
BACKGROUND: Multiparametric magnetic resonance imaging (mpMRI) interpreted by experts is a powerful tool for diagnosing prostate cancer. However, the generalizability of published results across radiologists of varying expertise has not been verified. OBJECTIVE: To assess variability in mpMRI reporting and diagnostic accuracy across radiologists of varying experience in routine clinical care. DESIGN, SETTING, AND PARTICIPANTS: Men who underwent mpMRI and MR-fusion biopsy between 2014-2016. Each MRI scan was read by one of nine radiologists using the Prostate Imaging Reporting and Data System (PIRADS) and was not re-read before biopsy. Biopsy histopathology was the reference standard. OUTCOME MEASUREMENTS AND STATISTICAL ANALYSIS: Outcomes were the PIRADS score distribution and diagnostic accuracy across nine radiologists. We evaluated the association between age, prostate-specific antigen, PIRADS score, and radiologist in predicting clinically significant cancer (Gleason ≥7) using multivariable logistic regression. We conducted sensitivity analyses for case volume and changes in accuracy over time. RESULTS AND LIMITATIONS: We analyzed data for 409 subjects with 503 MRI lesions. While the number of lesions (mean 1.2 lesions/patient) did not differ across radiologists, substantial variation existed in PIRADS distribution and cancer yield. The significant cancer detection rate was 3-27% for PIRADS 3 lesions, 23-65% for PIRADS 4, and 40-80% for PIRADS 5 across radiologists. Some 13-60% of men with a PIRADS score of <3 on MRI harbored clinically significant cancer. The area under the receiver operating characteristic curve varied from 0.69 to 0.81 for detection of clinically significant cancer. PIRADS score (p<0.0001) and radiologist (p=0.042) were independently associated with cancer in multivariable analysis. Neither individual radiologist volume nor study period impacted the results. MRI scans were not retrospectively re-read by all radiologists, precluding measurement of inter-observer agreement. CONCLUSIONS: We observed considerable variability in PIRADS score assignment and significant cancer yield across radiologists. We advise internal evaluation of mpMRI accuracy before widespread adoption. PATIENT SUMMARY: We evaluated the interpretation of multiparametric magnetic resonance imaging of the prostate in routine clinical care. Diagnostic accuracy depends on the Prostate Imaging Reporting and Data System score and the radiologist.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Ahmed, H. U., El-Shater Bosaily, A., Brown, L. C., Gabe, R., Kaplan, R., Parmar, M. K., Collaco-Moraes, Y., Ward, K., Hindley, R. G., Freeman, A., et al. (2017) · The Lancet · doi:10.1016/s0140-6736(16)32401-1 · Cited by 3,284
PI-RADS Prostate Imaging – Reporting and Data System: 2015, Version 2
Weinreb, J. C., Barentsz, J. O., Choyke, P. L., Cornud, F., Haider, M. A., Macura, K. J., Margolis, D., Schnall, M. D., Shtern, F., Tempany, C. M., et al. (2016) · European Urology · doi:10.1016/j.eururo.2015.08.052 · Cited by 2,951
ESUR prostate MR guidelines 2012
Barentsz, J. O., Richenberg, J., Clements, R., Choyke, P., Verma, S., Villeirs, G., Rouviere, O., Logager, V., & Fütterer, J. J. (2012) · European Radiology · doi:10.1007/s00330-011-2377-y · Cited by 2,438
Rosenkrantz, A. B., Ginocchio, L. A., Cornfeld, D., Froemming, A. T., Gupta, R. T., Turkbey, B., Westphalen, A. C., Babb, J. S., & Margolis, D. J. (2016) · Radiology · doi:10.1148/radiol.2016152542 · Cited by 501
Moore, C. M., Kasivisvanathan, V., Eggener, S., Emberton, M., Fütterer, J. J., Gill, I. S., Grubb III, R. L., Hadaschik, B., Klotz, L., Margolis, D. J. A., et al. (2013) · European Urology · doi:10.1016/j.eururo.2013.03.030 · Cited by 450
Pinto, P. A., Chung, P. H., Rastinehad, A. R., Baccala, A. A., Kruecker, J., Benjamin, C. J., Xu, S., Yan, P., Kadoury, S., Chua, C., et al. (2011) · Journal of Urology · doi:10.1016/j.juro.2011.05.078 · Cited by 450
Muller, B. G., Shih, J. H., Sankineni, S., Marko, J., Rais-Bahrami, S., George, A. K., de la Rosette, J. J. M. C. H., Merino, M. J., Wood, B. J., Pinto, P., et al. (2015) · Radiology · doi:10.1148/radiol.2015142818 · Cited by 331
Vargas, H. A., Hötker, A. M., Goldman, D. A., Moskowitz, C. S., Gondo, T., Matsumoto, K., Ehdaie, B., Woo, S., Fine, S. W., Reuter, V. E., et al. (2016) · European Radiology · doi:10.1007/s00330-015-4015-6 · Cited by 321
Woo, S., Suh, C. H., Kim, S. Y., Cho, J. Y., & Kim, S. H. (2017) · European Urology · doi:10.1016/j.eururo.2017.01.042 · Cited by 308
Greer, M. D., Brown, A. M., Shih, J. H., Summers, R. M., Marko, J., Law, Y. M., Sankineni, S., George, A. K., Merino, M. J., Pinto, P. A., et al. (2017) · Journal of Magnetic Resonance Imaging · doi:10.1002/jmri.25372 · Cited by 212
Cited by
Sathianathen, N. J., Omer, A., Harriss, E., Davies, L., Kasivisvanathan, V., Punwani, S., Moore, C. M., Kastner, C., Barrett, T., Van Den Bergh, R. C., et al. (2020) · European Urology · doi:10.1016/j.eururo.2020.03.048 · Cited by 346
Padhani, A. R., Weinreb, J., Rosenkrantz, A. B., Villeirs, G., Turkbey, B., & Barentsz, J. (2019) · European Urology · doi:10.1016/j.eururo.2018.05.035 · Cited by 288
Prostate cancer detection using deep convolutional neural networks
Yoo, S., Gujrathi, I., Haider, M. A., & Khalvati, F. (2019) · Scientific Reports · doi:10.1038/s41598-019-55972-4 · Cited by 230
Radiology-GPT: A Large Language Model for Radiology
Liu, Z., Zhong, A., Li, Y., Yang, L., Ju, C., Wu, Z., Ma, C., Shu, P., Chen, C., Kim, S., et al. (2023) · arXiv · doi:10.48550/arxiv.2306.08666 · Cited by 59
“There could be significant variations in how different radiologists interpret the same set of radiology findings [39, 40, 41].”
Werner, R. A., Bundschuh, R. A., Bundschuh, L., Javadi, M. S., Leal, J. P., Higuchi, T., Pienta, K. J., Buck, A. K., Pomper, M. G., Gorin, M. A., et al. (2018) · Journal of Nuclear Medicine · doi:10.2967/jnumed.118.217588 · Cited by 55
Metadata
- Authors
- Sonn, G. A., Fan, R. E., Ghanouni, P., Wang, N. N., Brooks, J. D., Loening, A. M., Daniel, B. L., To’o, K. J., Thong, A. E., & Leppert, J. T.
- Venue
- European Urology Focus
- Publisher
- Elsevier BV
- Published
- 2019-07
- Volume
- 5
- Issue
- 4
- Pages
- 592-599
- ISSN
- 2405-4569 (ISSN-L)
- OpenAlex
- W2775769660
- Cited by
- 278
- References
- 14
- FWCI
- 17.62
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.