CoChat

Ambulatory measurement of the scapulohumeral rhythm: Intra- and inter-operator agreement of a protocol based on inertial and magnetic sensors

Open access
Parel, I., Cutti, A.G., Fiumana, G., Porcellini, G., Verni, G., Accardo, A.P. · 2012 · Gait & Posture
Cited by 73

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Abstract

To measure the scapulohumeral rhythm (SHR) in outpatient settings, the motion analysis protocol named ISEO (INAIL Shoulder and Elbow Outpatient protocol) was developed, based on inertial and magnetic sensors. To complete the sensor-to-segment calibration, ISEO requires the involvement of an operator for sensor placement and for positioning the patient's arm in a predefined posture. Since this can affect the measure, this study aimed at quantifying ISEO intra- and inter-operator agreement. Forty subjects were considered, together with two operators, A and B. Three measurement sessions were completed for each subject: two by A and one by B. In each session, the humerus and scapula rotations were measured during sagittal and scapular plane elevation movements. ISEO intra- and inter-operator agreement were assessed by computing, between sessions, the: (1) similarity of the scapulohumeral patterns through the Coefficient of Multiple Correlation (CMC(2)), both considering and excluding the difference of the initial value of the scapula rotations between two sessions (inter-session offset); (2) 95% Smallest Detectable Difference (SDD(95)) in scapula range of motion. Results for CMC(2) showed that the intra- and inter-operator agreement is acceptable (median≥0.85, lower-whisker ≥ 0.75) for most of the scapula rotations, independently from the movement and the inter-session offset. The only exception is the agreement for scapula protraction-retraction and for scapula medio-lateral rotation during abduction (inter-operator), which is acceptable only if the inter-session offset is removed. SDD(95) values ranged from 4.4° to 8.6° for the inter-operator and between 4.9° and 8.5° for the intra-operator agreement. In conclusion, ISEO presents a high intra- and inter-operator agreement, particularly with the scapula inter-session offset removed.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.gaitpost.2011.12.015

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 73

Metadata

Authors
Parel, I., Cutti, A. G., Fiumana, G., Porcellini, G., Verni, G., & Accardo, A. P.
Venue
Gait & Posture
Publisher
Elsevier BV
Published
2012-04
Volume
35
Issue
4
Pages
636-640
ISSN
0966-6362 (ISSN-L)
OpenAlex
W2030847909
Cited by
73
References
1
FWCI
5.41
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.