The DOI matches its Crossref record; 13 of the 13 references it cites were found in a registry or an index.
The relationship between contact force and clinical outcome during radiofrequency catheter ablation of atrial fibrillation in the TOCCATA study
Open accessAbstract
BACKGROUND The clinical efficacy of catheter ablation of paroxysmal atrial fibrillation (AF) remains limited by difficulty in achieving durable pulmonary vein isolation (PVI). Suboptimal catheter tip-to-tissue contact force (CF) during lesion delivery is believed to reduce clinical efficacy. OBJECTIVE To determine the relationship between catheter CF during irrigated catheter ablation for AF and clinical recurrences during follow-up. METHODS Thirty-two patients with paroxysmal AF underwent PVI by using a radiofrequency ablation catheter with a CF sensor integrated at its tip, and they were followed for 12 months. The relationship between the CF and clinical outcomes was determined. RESULTS Acute PVI was achieved in 100% of the veins. Thirty-five percent (351 of 1017) of the applications were placed with an average CF of <10 g (low CF). All patients treated with an average CF of <10 g (5 of 5 patients) experienced recurrences, whereas 80% of the patients treated with an average CF of >20 g (8 of 10 patients) were free from AF recurrence at 12 months. The analysis of the average force-time integral showed that 75% of the patients treated with <500 gs were recurrent whereas only 31% of the patients treated with >1000 gs had recurrences at 12 months. CONCLUSIONS The CF during catheter ablation for AF correlates with clinical outcome. Arrhythmia control is best achieved when ablation lesions are placed with an average CF of >20 g, and clinical failure is universally noted with an average CF of <10 g.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cappato, R., Calkins, H., Chen, S.-A., Davies, W., Iesaka, Y., Kalman, J., Kim, Y.-H., Klein, G., Natale, A., Packer, D., et al. (2010) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.109.859116 · Cited by 2,852
Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., Lowe, J. E., et al. (2006) · Circulation · doi:10.1161/circulationaha.106.177292 · Cited by 2,805
Calkins, H., Kuck, K. H., Cappato, R., Brugada, J., Camm, A. J., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., DiMarco, J., et al. (2012) · Europace · doi:10.1093/europace/eus027 · Cited by 2,722
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Heart Rhythm · doi:10.1016/j.hrthm.2007.04.005 · Cited by 1,701
Self-citationCalkins, H., Brugada, J., Packer, D. L., Cappato, R., Chen, S.-A., Crijns, H. J. G., Damiano, R. J., Davies, D. W., Haines, D. E., Haissaguerre, M., et al. (2007) · Europace · doi:10.1093/europace/eum120 · Cited by 1,290
Self-citationOuyang, F., Antz, M., Ernst, S., Hachiya, H., Mavrakis, H., Deger, F. T., Schaumann, A., Chun, J., Falk, P., Hennig, D., et al. (2005) · Circulation · doi:10.1161/01.cir.0000151289.73085.36 · Cited by 793
Self-citationAuthors/Task Force Members, Fuster, V., Rydén, L. E., Cannom, D. S., Crijns, H. J., Curtis, A. B., Ellenbogen, K. A., Halperin, J. L., Le Heuzey, J.-Y., Kay, G. N., et al. (2006) · European Heart Journal · doi:10.1093/eurheartj/ehl176 · Cited by 644
Yokoyama, K., Nakagawa, H., Shah, D. C., Lambert, H., Leo, G., Aeby, N., Ikeda, A., Pitha, J. V., Sharma, T., Lazzara, R., et al. (2008) · Circulation: Arrhythmia and Electrophysiology · doi:10.1161/circep.108.803650 · Cited by 624
Self-citationVerma, A., Kilicaslan, F., Pisano, E., Marrouche, N. F., Fanelli, R., Brachmann, J., Geunther, J., Potenza, D., Martin, D. O., Cummings, J., et al. (2005) · Circulation · doi:10.1161/circulationaha.104.533190 · Cited by 402
Self-citationA novel radiofrequency ablation catheter using contact force sensing: Toccata study
Kuck, K.-H., Reddy, V. Y., Schmidt, B., Natale, A., Neuzil, P., Saoudi, N., Kautzner, J., Herrera, C., Hindricks, G., Jaïs, P., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2011.08.021 · Cited by 311
Self-citationHAINES, D. E. (1991) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.1991.tb01353.x · Cited by 264
Seiler, J., Roberts‐Thomson, K. C., Raymond, J., Vest, J., Delacrétaz, E., & Stevenson, W. G. (2008) · Heart Rhythm · doi:10.1016/j.hrthm.2008.07.011 · Cited by 151
Edgerton, J. R., Brinkman, W. T., Weaver, T., Prince, S. L., Culica, D., Herbert, M. A., & Mack, M. J. (2010) · The Journal of Thoracic and Cardiovascular Surgery · doi:10.1016/j.jtcvs.2009.11.065 · Cited by 99
Cited by
Calkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,755
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y.-H., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2018) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,164
Self-citationCalkins, H., Hindricks, G., Cappato, R., Kim, Y., Saad, E. B., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, J., et al. (2017) · Journal of Arrhythmia · doi:10.1016/j.joa.2017.08.001 · Cited by 707
Self-citationTzeis, S., Gerstenfeld, E. P., Kalman, J., Saad, E. B., Sepehri Shamloo, A., Andrade, J. G., Barbhaiya, C. R., Baykaner, T., Boveda, S., Calkins, H., et al. (2024) · Europace · doi:10.1093/europace/euae043 · Cited by 634
Self-citationAndrade, J. G., Champagne, J., Dubuc, M., Deyell, M. W., Verma, A., Macle, L., Leong-Sit, P., Novak, P., Badra-Verdu, M., Sapp, J., et al. (2019) · Circulation · doi:10.1161/circulationaha.119.042622 · Cited by 570
Metadata
- Authors
- Reddy, V. Y., Shah, D., Kautzner, J., Schmidt, B., Saoudi, N., Herrera, C., Jaïs, P., Hindricks, G., Peichl, P., Yulzari, A., Lambert, H., Neuzil, P., Natale, A., & Kuck, K.-H.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2012-11
- Volume
- 9
- Issue
- 11
- Pages
- 1789-1795
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W2124862399
- Cited by
- 484
- References
- 13
- FWCI
- 28.39
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.