The DOI matches its Crossref record; 57 of the 58 references it cites were found in a registry or an index.
Wearables in cardiology: Here to stay
Abstract
The adoption of wearables in medicine has rapidly expanded worldwide. New generations of wearables are emerging, driven by consumers' demand to monitor their own health. With the ongoing development of new features capable of assessing real-time biometric data, the impact of wearables on cardiovascular management has become inevitable. Smartwatches, among other wearable devices, offer a user-friendly noninvasive approach to continuously monitor for health parameters. With advancements in artificial intelligence, the photoplethysmography-generated pulse waveform has the potential to accurately detect episodes of atrial fibrillation and one day could replace conventional diagnostic and long-term monitoring methods. Clinical benefits that could arise from the use of such devices include refining stroke prevention strategies, personalizing AF management, and optimizing the patient-physician relationship. Wearables are changing not only the way clinicians conduct research but also the future of cardiovascular preventive and therapeutic care. As such, wearables are here to stay.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Skin colour, moisture and even tattoos have also been postulated to affect PPG accuracy20”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [20]
In the citing paper
“These studies highlight that PPG HR readings from wrist-worn devices during activity should be interpreted with caution20, whereas less convenient, chest-strap monitors are more accurate.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [20]
In the citing paper
“Wearables might be a convenient tool to diagnose asymptomatic or symptomatic AF20.”
From Smart wearable devices in cardiovascular care: Where we are and how to move forward (2021) · cites this paper as [20]
Citations
Cites
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
Calkins, H. G., Hindricks, G., Cappato, R., Kim, Y., Saad, E., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, A. J., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.05.012 · Cited by 2,794
Cryptogenic stroke and underlying atrial fibrillation
Sanna, T., Diener, H.-C., Passman, R. S., Di Lazzaro, V., Bernstein, R. A., Morillo, C. A., Rymer, M. M., Thijs, V., Rogers, T., Beckers, F., et al. (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1313600 · Cited by 2,161
Large-Scale Assessment of a Smartwatch to Identify Atrial Fibrillation
Perez, M. V., Mahaffey, K. W., Hedlin, H., Rumsfeld, J. S., Garcia, A., Ferris, T., Balasubramanian, V., Russo, A. M., Rajmane, A., Cheung, L., et al. (2019) · New England Journal of Medicine · doi:10.1056/nejmoa1901183 · Cited by 1,917
Wearable Sensors for Remote Health Monitoring
Majumder, S., Mondal, T., & Deen, M. (2017) · Sensors · doi:10.3390/s17010130 · Cited by 1,375
Colilla, S., Crow, A., Petkun, W., Singer, D. E., Simon, T. A., & Liu, X. (2013) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2013.05.063 · Cited by 1,323
Calkins, H. G., Hindricks, G., Cappato, R., Kim, Y., Saad, E., Aguinaga, L., Akar, J. G., Badhwar, V., Brugada, J., Camm, A. J., et al. (2017) · EP Europace · doi:10.1093/europace/eux274 · Cited by 1,203
Long-Term Effect of Goal-Directed Weight Management in an Atrial Fibrillation Cohort
Pathak, R. K., Middeldorp, M. E., Meredith, M., Mehta, A. B., Mahajan, R., Wong, C. X., Twomey, D., Elliott, A. D., Kalman, J. M., Abhayaratna, W. P., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.03.002 · Cited by 1,036
Pathak, R. K., Middeldorp, M. E., Lau, D. H., Mehta, A. B., Mahajan, R., Twomey, D., Alasady, M., Hanley, L., Antic, N. A., McEvoy, R. D., et al. (2014) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2014.09.028 · Cited by 949
Ghamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Flagged first, then by citations
1 of the 58 references couldn’t be matched to a known paper.
Cited by
Sorted by citations
Smart wearable devices in cardiovascular care: Where we are and how to move forward
Bayoumy, K., Gaber, M., Elshafeey, A., Mhaimeed, O., Dineen, E. H., Marvel, F. A., Martin, S. S., Muse, E. D., Turakhia, M. P., Tarakji, K. G., et al. (2021) · Nature Reviews Cardiology · doi:10.1038/s41569-021-00522-7 · Cited by 829
Sauerbrei, A., Kerasidou, A., Lucivero, F., & Hallowell, N. (2023) · BMC Medical Informatics and Decision Making · doi:10.1186/s12911-023-02162-y · Cited by 353
“2020) [31] Exploratory review and opinion piece Assesses the role of wearables in cardiology and outlining the benefits associated with their use USA”
BackgroundWearable Devices for Physical Monitoring of Heart: A Review
Prieto-Avalos, G., Cruz-Ramos, N. A., Alor‐Hernández, G., Sánchez-Cervantes, J. L., Rodríguez-Mazahua, L., & Guarneros-Nolasco, L. R. (2022) · Biosensors · doi:10.3390/bios12050292 · Cited by 275
Huang, J.-D., Wang, J., Ramsey, E., Leavey, G., Chico, T., & Condell, J. V. (2022) · Sensors · doi:10.3390/s22208002 · Cited by 203
“With advancements in artificial intelligence, the signal acquired from the devices will help realise the potential to accurately detect episodes of atrial fibrillation and may replace conventional diagnostic and long-term monitoring methods [130].”
Clinical Validation of 5 Direct-to-Consumer Wearable Smart Devices to Detect Atrial Fibrillation
Mannhart, D., Lischer, M., Knecht, S., du Fay de Lavallaz, J., Strebel, I., Serban, T., Vögeli, D., Schaer, B., Osswald, S., Mueller, C., et al. (2023) · JACC: Clinical Electrophysiology · doi:10.1016/j.jacep.2022.09.011 · Cited by 175
Li, K., Cardoso, C., Moctezuma-Ramirez, A., Elgalad, A., & Perin, E. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20247146 · Cited by 160
“Skin color, tattoos, and moisture can also affect PPG accuracy [27,28].”
BackgroundDhingra, L. S., Aminorroaya, A., Oikonomou, E. K., Nargesi, A. A., Wilson, F. P., Krumholz, H. M., & Khera, R. (2023) · JAMA Network Open · doi:10.1001/jamanetworkopen.2023.16634 · Cited by 158
Neri, L., Oberdier, M. T., van Abeelen, K. C. J., Menghini, L., Tumarkin, E., Tripathi, H., Jaipalli, S., Orro, A., Paolocci, N., Gallelli, I., et al. (2023) · Sensors · doi:10.3390/s23104805 · Cited by 148
“The use of single-lead ECG has the potential to give important diagnostic information on the user’s health [1,5] but also has some limitations compared to the standard 12-lead ECG [6].”
BackgroundAlugubelli, N. R., Abuissa, H. S., & Róka, A. (2022) · Sensors · doi:10.3390/s22228903 · Cited by 154
Javaid, A., Zghyer, F., Kim, C., Spaulding, E. M., Isakadze, N., Ding, J., Kargilis, D., Gao, Y., Rahman, F., Brown, D. E., et al. (2022) · American Journal of Preventive Cardiology · doi:10.1016/j.ajpc.2022.100379 · Cited by 119
“Devices, especially wearables and sensors, must be optimized for all skin-colors and body types [104].”
BackgroundConsumer Wearable Health and Fitness Technology in Cardiovascular Medicine
Petek, B. J., Al‐Alusi, M. A., Moulson, N., Grant, A. J., Besson, C., Guseh, J. S., Wasfy, M. M., Grémeaux, V., Churchill, T. W., & Baggish, A. L. (2023) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2023.04.054 · Cited by 113
Wearable Devices: Current Status and Opportunities in Pain Assessment and Management
Leroux, A., Lynn, R. R., Crainiceanu, C., & Sharma, T. (2021) · Digital Biomarkers · doi:10.1159/000515576 · Cited by 94
Ferguson, C., Hickman, L., Turkmani, S., Breen, P. P., Gargiulo, G. D., & Inglis, S. C. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2021.02.001 · Cited by 88
“However, many issues remain and need to be addressed to enhance uptake.(1,2) There is a paucity of research exploring factors that help to understand barriers and facilitators to inform the acceptance, adoption, wearability, and sustainability of use.”
BackgroundMethods for Heart Rate Variability Biofeedback (HRVB): A Systematic Review and Guidelines
Lalanza, J. F., Lorente, S., Bullich, R., García, C., Losilla, J.-M., & Capdevila, L. (2023) · Applied Psychophysiology and Biofeedback · doi:10.1007/s10484-023-09582-6 · Cited by 111
Biomechanical Sensing Systems for Cardiac Activity Monitoring
Owida, H. A. (2022) · International Journal of Biomaterials · doi:10.1155/2022/8312564 · Cited by 76
Baygin, M., Tuncer, T., Doğan, Ş., Tan, R., & Acharya, U. R. (2021) · Information Sciences · doi:10.1016/j.ins.2021.06.022 · Cited by 67
mHealth Apps for Self-Management of Cardiovascular Diseases: A Scoping Review
Cruz-Ramos, N. A., Alor‐Hernández, G., Colombo-Mendoza, L. O., Sánchez-Cervantes, J. L., Rodríguez-Mazahua, L., & Guarneros-Nolasco, L. R. (2022) · Healthcare · doi:10.3390/healthcare10020322 · Cited by 66
Wang, Y.-C., Xu, X., Hajra, A., Apple, S. J., Kharawala, A., Duarte, G., Liaqat, W., Fu, Y., Li, W., Chen, Y., et al. (2022) · Diagnostics · doi:10.3390/diagnostics12030689 · Cited by 55
“To refine precision, algorithms have been developed to differentiate AF from other benign irregular heart rhythms, such as bigeminy or premature beats, without requiring electrocardiographic corroboration [55].”
MethodXintarakou, A., Sousonis, V., Asvestas, D., Vardas, P. E., & Tzeis, S. E. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.853614 · Cited by 58
“Inevitably, the wide spread of smartwatches that incorporate heart rhythm sensors among the population, raises queries about their role in AF screening and diagnosis (50), which is still controversial (78).”
BackgroundWearable and digital devices to monitor and treat metabolic diseases
Keshet, A., Reicher, L., Bar, N., & Segal, E. (2023) · Nature Metabolism · doi:10.1038/s42255-023-00778-y · Cited by 53
Carbon Dioxide Sensing—Biomedical Applications to Human Subjects
Dervieux, E., Théron, M., & Uhring, W. (2021) · Sensors · doi:10.3390/s22010188 · Cited by 54
Bahru, R., Hamzah, A. A., & Mohamed, M. A. (2020) · International Journal of Energy Research · doi:10.1002/er.6031 · Cited by 48
The Impact of Heart Rate Variability Monitoring on Preventing Severe Cardiovascular Events
Turcu, A.-M., Ilie, A. C., Ștefăniu, R., Țăranu, S. M., Sandu, I. A., Alexa‐Stratulat, T., Pîslaru, A. I., & Alexa, I. D. (2023) · Diagnostics · doi:10.3390/diagnostics13142382 · Cited by 46
“- Skin color, humidity, or tattoos can affect the accuracy of monitoring [26].”
BackgroundMonitoring of Dynamic Plantar Foot Temperatures in Diabetes with Personalised 3D-Printed Wearables
Beach, C., Cooper, G., Weightman, A., Hodson-Tole, E. F., Reeves, N. D., & Casson, A. J. (2021) · Sensors · doi:10.3390/s21051717 · Cited by 44
“Wearable devices are becoming increasingly common for use in preventative medicine in areas such as cardiovascular health [6], motivating the creation of wearables for monitoring risk factors in DFU.”
BackgroundAckerman, K. E., Rogers, M. A., Heikura, I. A., Burke, L. M., Stellingwerff, T., Hackney, A. C., Verhagen, E., Schley, S., Saville, G. H., Mountjoy, M., et al. (2023) · British Journal of Sports Medicine · doi:10.1136/bjsports-2023-107359 · Cited by 43
Artificial intelligence for a personalized diagnosis and treatment of atrial fibrillation
Nava, A., Atienza, F., Bermejo, J., & Fernández‐Avilés, F. (2021) · American Journal of Physiology-Heart and Circulatory Physiology · doi:10.1152/ajpheart.00764.2020 · Cited by 43
Cardiovascular Care Innovation through Data-Driven Discoveries in the Electronic Health Record
Dhingra, L. S., Shen, M., Mangla, A., & Khera, R. (2023) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2023.06.104 · Cited by 42
Marvasti, T. B., Gao, Y., Murray, K. R., Hershman, S., McIntosh, C., & Moayedi, Y. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.07.009 · Cited by 35
Emerging intelligent wearable devices for cardiovascular health monitoring
Wang, Y., Zou, Y., & Li, Z. (2024) · Nano Today · doi:10.1016/j.nantod.2024.102544 · Cited by 38
Scalably Nanomanufactured Atomically Thin Materials‐Based Wearable Health Sensors
Zhang, R., Jiang, J. S., & Wu, W. (2021) · Small Structures · doi:10.1002/sstr.202100120 · Cited by 35
Atrial Fibrillation in Heart Failure: Novel Insights, Challenges, and Treatment Opportunities
Bidaoui, G., Assaf, A. Y. M., & MARROUCHE, N. F. (2024) · Current Heart Failure Reports · doi:10.1007/s11897-024-00691-9 · Cited by 41
Self-citationBridging gaps and optimizing implementation of guideline-directed medical therapy for heart failure.
Shahid, I., Khan, M. S., Fonarow, G., Butler, J., & Greene, S. (2024) · Progress in cardiovascular diseases · doi:10.1016/j.pcad.2024.01.008 · Cited by 28
Hassan, L., Milton, A. C., Sawyer, C. S., Casson, A. J., Torous, J. B., Davies, A., Ruiz‐Yu, B., & Firth, J. (2025) · JMIR Mental Health · doi:10.2196/65143 · Cited by 35
“Meanwhile, in other chronic diseases [12-14] and in the general population [15], monitoring and promoting physical health appears to be a far more common use case for wearables.”
Leveraging Machine Learning for Disease Diagnoses Based on Wearable Devices: A Survey
Jiang, Z., van Zoest, V., Deng, W., Ngai, E. C. ‐., & Liu, J. (2023) · IEEE Internet of Things Journal · doi:10.1109/jiot.2023.3313158 · Cited by 32
“Dagher et al. [91] echoed that PPG-generated pulse wave-form has the potential to accurately detect episodes of AF and one day could replace conventional diagnostic and long-term monitoring methods.”
BackgroundBabar, F., Cheema, A. M., Ahmad, Z., Sarfraz, A., Sarfraz, Z., Ashraff, H., Tayyab, H., Bajwa, A. M., Ali, H., Sarfraz, M., et al. (2023) · Current Cardiology Reports · doi:10.1007/s11886-023-01898-3 · Cited by 31
Wearables in Cardiovascular Disease
Kumar, S., Victoria‐Castro, A. M., Melchinger, H. C., O’Connor, K. D., Psotka, M. A., Desai, N. R., Ahmad, T., & Wilson, F. P. (2022) · Journal of Cardiovascular Translational Research · doi:10.1007/s12265-022-10314-0 · Cited by 27
“These sensors detect the small variations in blood volume caused by each heartbeat using the intensity of light reflected from skin capillaries, which is proportional to the blood volume and its light absorption [12, 13].”
BackgroundInfluentialMechanical Sensors for Cardiovascular Monitoring: From Battery-Powered to Self-Powered
Tang, C., Liu, Z., & Li, L. (2022) · Biosensors · doi:10.3390/bios12080651 · Cited by 33
“, low signal-to-noise ratio, and therefore is not a viable solution [7].”
BackgroundContinuous Movement Monitoring at Home Through Wearable Devices: A Systematic Review
Farabolini, G., Baldini, N., Pagano, A., Andrenelli, E., Pepa, L., Morone, G., Ceravolo, M. G., & Capecci, M. (2025) · Sensors · doi:10.3390/s25164889 · Cited by 27
“…wearable sensors [5,6], to light portable sensor devices for detecting health signals such as the following: pulse rate [7,8], blood pressure [9], or ECG [10]; blood glucose levels [11]; blood oxygen saturation or respiratory rate [12,13]; and neurological signals for the detection of…”
InfluentialMannhart, D., Lefebvre, B., Gardella, C., Henry, C., Serban, T., Knecht, S., Kühne, M., Sticherling, C., & Badertscher, P. (2023) · Archives of cardiovascular diseases · doi:10.1016/j.acvd.2023.04.003 · Cited by 23
Algorithm for Mobile Platform-Based Real-Time QRS Detection
Neri, L., Oberdier, M. T., Augello, A., Suzuki, M., Tumarkin, E., Jaipalli, S., Geminiani, G. A., Halperin, H. R., & Borghi, C. (2023) · Sensors · doi:10.3390/s23031625 · Cited by 22
Wouters, F., Gruwez, H., Smeets, C. J. P. P., Pijalovic, A., Wilms, W., Vranken, J., Pieters, Z., Herendael, H. V., Nuyens, D., Rivero‐Ayerza, M., et al. (2024) · JMIR Formative Research · doi:10.2196/65139 · Cited by 25
“However, the 21st century has witnessed a rapid surge in the availability and use of consumer-oriented wearable devices (CWDs) capable of monitoring heart rhythm [5-8].”
Zeng, Q., Huang, C., & Zhu, J. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1656603 · Cited by 20
Tiwari, A., Cassani, R., Kshirsagar, S., Tobón, D. P., Zhu, Y. M., & Falk, T. H. (2022) · Sensors · doi:10.3390/s22124579 · Cited by 18
“In addition to COVID-19 infection monitoring, wearables have shown to disrupt numerous healthcare domains, including cardiology [5], gait analysis [6], sleep quality [7], clinical trials during cancer treatment [8], stress management [9], and emotion/depression [10], just to name a few.”
BackgroundBrunetti, N. D., Curcio, A., Nodari, S., Parati, G., Carugo, S., Molinari, M., Acquistapace, F., Gensini, G., & Molinari, G. (2023) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0000000000001447 · Cited by 18
Ahmad, R. U. S., Khan, W. U., Khan, M. S., & Cheung, P. (2025) · Materials Today Bio · doi:10.1016/j.mtbio.2025.101663 · Cited by 20
Chandrasekaran, R., Sharma, P. K., & Moustakas, E. (2023) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2411307 · Cited by 16
“In recent years, wearable smartwatches have exhibited their potential in prevention, assessment and continuous patient monitoring, aiding in diagnosis and treatment of CVD problems, and offering various assistance functionalities [6–8].”
BackgroundNeri, L., Corazza, I., Oberdier, M. T., Lago, J., Gallelli, I., Cicero, A. F. G., Diemberger, I., Orro, A., Beker, A., Paolocci, N., et al. (2024) · Journal of Medical Systems · doi:10.1007/s10916-024-02077-9 · Cited by 14
“For example, poor ECG signals for patients 1, 5, 22, and 29 are potentially due to patient-related factors such as the activities performed by the subjects during the 24 h, possible electrode-garment interactions, and sleep positions that could have reduced the electrode-skin contacts.”
BackgroundCurrent and Potential Applications of Wearables in Sports Cardiology
Rao, P., Seshadri, D. R., & Hsu, J. J. (2021) · Current Treatment Options in Cardiovascular Medicine · doi:10.1007/s11936-021-00942-1 · Cited by 18
“It is important to also consider that skin color, moisture, and tattoos may affect the accuracy of wrist-worn monitors [14].”
BackgroundClosed-Loop Systems in Neuromodulation
Montenegro, T. S., Ali, R., & Arle, J. E. (2022) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2022.02.008 · Cited by 13
Dagher, L., Nedunchezhian, S., Hajjar, A. H. E., Zhang, Y., Deffer, O., Russell, A., Pottle, C., & Marrouche, N. F. (2021) · Cardiovascular Digital Health Journal · doi:10.1016/j.cvdhj.2021.10.007 · Cited by 13
Self-citationMultiple imputation approaches for epoch-level accelerometer data in trials
Tackney, M. S., Williamson, E., Cook, D. G., Limb, E. S., Harris, T. J., & Carpenter, J. R. (2023) · Statistical Methods in Medical Research · doi:10.1177/09622802231188518 · Cited by 12
“While our study has focused on accelerometer studies, there is a growing need to consider missingness at a finer epoch-level for a number of health outcomes in trials, particularly as continuous monitoring participants through digital devices become more common (Dagher et al., 2020).”
Sevak, K. Y., & GEORGE, B. P. (2024) · Journal of Internet and Digital Economics · doi:10.1108/jide-12-2023-0026 · Cited by 11
Convolutional Neural Networks for Mechanistic Driver Detection in Atrial Fibrillation
Ríos-Muñoz, G. R., Fernández‐Avilés, F., & Arenal, Á. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23084216 · Cited by 11
“…variability [10], computed tomography (CT), magnetic resonance imaging (MRI) 3D ventricular-atrial segmentation [11], diagnosis of arrhythmias in wearable devices [12], guidance in irregular heart electrical activity, and more specifically atrial fibrillation (AF) electroanatomical mapping [13–15].”
Pastorino, R., Pezzullo, A. M., Agodi, A., de Waure, C., Mazzucco, W., Russo, L., Bianchi, M., Maio, A., Farina, S., Porcelli, M., et al. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1335894 · Cited by 10
Gehrmann, J., Hahn, F., Stephan, J., Steger, A., Rattka, M., Rudolph, I., Federle, D., Heller, J., Wunderlin, G. C. G. J., Laugwitz, K., et al. (2025) · Telemedicine Journal and e-Health · doi:10.1089/tmj.2024.0528 · Cited by 12
Accuracy of Heart Rate Measurements of Three Smartwatch Models in Dogs
Yanmaz, L. E., Okur, S., Ersöz, U., Şenocak, M. G., & Turgut, F. (2022) · Topics in companion animal medicine · doi:10.1016/j.tcam.2022.100654 · Cited by 10
The Efficacy of Artificial Intelligence in the Detection and Management of Atrial Fibrillation
Popat, A., Yadav, S., Obholz, J., Hwang, E. A., Rehman, A. U., & Sharma, P. (2025) · Cureus · doi:10.7759/cureus.77135 · Cited by 9
RetractedConsumer wearable technologies to identify and monitor exercise-related arrhythmias in athletes
Sanchis‐Gomar, F., Lavie, C. J., & Perez, M. V. (2020) · Current Opinion in Cardiology · doi:10.1097/hco.0000000000000817 · Cited by 9
“The need to better understand the electrophysiologic impact of athleticism is one of the main drivers for the progress in using wearable devices to detect exercise-related arrhythmias [2].”
BackgroundInfluentialBaka, T., & Šimko, F. (2021) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2021.711417 · Cited by 9
Jahre, L. M., Lortz, J., Rassaf, T., Rammos, C., Mallien, C., Skoda, E., Teufel, M., & Bäuerle, A. (2023) · European Heart Journal - Digital Health · doi:10.1093/ehjdh/ztad038 · Cited by 9
Health 4.0, Prevention, and Health Promotion in Companies: A Systematic Literature Review
Domínguez-Miranda, S. A., & Rodríguez-Aguilar, R. (2023) · EAI/Springer Innovations in Communication and Computing · doi:10.1007/978-3-031-34750-4_13 · Cited by 9
Neri, L., Gallelli, I., Dall’Olio, M., Lago, J., Borghi, C., Diemberger, I., & Corazza, I. (2024) · Bioengineering · doi:10.3390/bioengineering11030222 · Cited by 8
“Electrocardiographic monitoring is crucial for detecting arrhythmias (e.g., atrial fibrillation, ventricular tachycardia or bradycardia, bundle branch blocks, etc.) [31].”
BackgroundRamírez, E., Ruipérez-Campillo, S., Casado-Arroyo, R., Merino, J. L., Vogt, J. E., Castells, F., & Millet, J. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2024.1452829 · Cited by 7
“Other common configurations consist of only a few leads, including out-of-hospital ECG monitoring with devices such as Holter monitors (Moody and Mark, 2001; Sharma and Baranchuk, 2021) or wearable devices (Dagher et al., 2020; Smital et al., 2020; Zepeda-Echavarria et al., 2023).”
Langebrake, C., Gottfried, K., Dadkhah, A., Eggert, J., Gutowski, T., Rosch, M., Schönbeck, N., Gundler, C., Nürnberg, S., Ückert, F., et al. (2023) · Clinical eHealth · doi:10.1016/j.ceh.2023.05.001 · Cited by 9
Dervieux, E., Guerrero, F., Uhring, W., Giroux‐Metges, M., & Théron, M. (2024) · Frontiers in Physiology · doi:10.3389/fphys.2023.1293752 · Cited by 7
“Additionally, the outbreak of contagious pandemics—such as COVID-19 (Garfan et al., 2021)—and the rapid development of the health wearable market (Dunn et al., 2018; Yetisen et al., 2018; Chung et al., 2019; Dagher et al., 2020) may also promote the use of telemonitoring in medical practice.”
BackgroundWearables in Sports Cardiology
Beavers, D. L., & Chung, E. H. (2022) · Clinics in Sports Medicine · doi:10.1016/j.csm.2022.02.004 · Cited by 7
Bhadri, K., Karnik, N., & Dhatrak, P. N. (2022) · International Conference on Emerging Trends in Engineering and Technology (ICETET) · doi:10.1109/icetet-sip-2254415.2022.9791776 · Cited by 7
Tran, H. H.-V., Urgessa, N. A., Geethakumari, P., Kampa, P., Parchuri, R., Bhandari, R., Alnasser, A. R., Akram, A., Kar, S., Osman, F., et al. (2023) · Cureus · doi:10.7759/cureus.50952 · Cited by 6
The effect of ECG data variability on side-channel attack success rate in wearable devices
Pérez-Tirador, P., Jevtić, R., Cabezaolias, C., Romero, T., Otero, A., & Caffarena, G. (2025) · Integration · doi:10.1016/j.vlsi.2025.102385 · Cited by 6
Adasuriya, G., & Haldar, S. (2022) · European Journal of Arrhythmia & Electrophysiology · doi:10.17925/ejae.2022.8.1.7 · Cited by 5
Fruytier, L., Janssen, D. M., Campero-Jurado, I., van de Sande, D. A., Lorato, I. R., Stuart, S., Panditha, P., de Kok, M., & Kemps, H. (2023) · JMIR Formative Research · doi:10.2196/49346 · Cited by 6
Takami, M., Fukuzawa, K., Kiuchi, K., Takemoto, M., Nakamura, T., Sakai, J., Yatomi, A., Nakasone, K., Sonoda, Y., Yamamoto, K., et al. (2021) · Circulation Reports · doi:10.1253/circrep.cr-21-0033 · Cited by 5
Emerging Image-Guided Navigation Techniques for Cardiovascular Interventions: A Scoping Review
Roshanfar, M., Salimi, M., Jang, S.-J., Sinusas, A. J., Kim, J., & Mosadegh, B. (2025) · Bioengineering · doi:10.3390/bioengineering12050488 · Cited by 4
Hearn, J., den Eynde, J. V., Chinni, B. K., Cedars, A. M., Sen, D. G., Kutty, S., & Manlhiot, C. (2023) · JMIR Cardio · doi:10.2196/40524 · Cited by 4
“For this purpose, such devices are well accepted by patients and physicians and are generally seen as an important component of future clinical protocols [1-3].”
BackgroundSpatial Data Governance for Healthcare Metaverse
Das, B. C., Zahid, R. B., Roy, P., & Ahmad, M. (2025) · Advances in computer and electrical engineering book series · doi:10.4018/979-8-3693-4373-9.ch013 · Cited by 3
Guler, S., Aslanger, E. K., & Yapici, M. K. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.11 · Cited by 3
“…(Timmis et al., 2022), wearable technology has evolved from basic activity trackers, such as smartwatches and bracelets (Wu et al., 2016), to high-grade medical products that can be worn for prolonged periods with utmost reliability and patient comfort (Dagher et al., 2020; Smuck et al., 2021).”
Goyal, A., Puttaswamy, D., Kadam, E., Maheshwari, S., Hurjkaliani, S., Goyal, P., Thakkar, K., Shah, V., Daoud, M., & Mahalwar, G. (2025) · American Heart Journal Plus Cardiology Research and Practice · doi:10.1016/j.ahjo.2025.100600 · Cited by 3
“[14,15].”
Nardini, S. G., Corbanese, U., Visconti, A., Mule, J. D., Sanguinetti, C. M., & Benedetto, F. D. (2023) · Multidisciplinary Respiratory Medicine · doi:10.4081/mrm.2023.922 · Cited by 3
Cheng, A., Krauter, M. B., Mullen, K., & Liu, P. P. (2024) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2024.06.001 · Cited by 3
Healthcare 4.0 – Medizin im Wandel
Roßkopf, S., & Meder, B. (2024) · Herz · doi:10.1007/s00059-024-05267-w · Cited by 3
“Die-se tragbaren Geräte wie Smartwatches und Fitnessarmbänder sind mit Sensoren und Chips ausgestattet, die kontinuierlich wichtige Gesundheitsdaten wie Herzfre-quenz, Elektrokardiogramm (EKG) und Blutdruck aufzeichnen, überwachen und in Zukunft mit Algorithmen interpretie-ren können [15].”
From Beat to Risk: How Heart Rate Variability Predicts Arrhythmias in Type 2 Diabetes
Bobu, A. M., Duca, Ș.-T., Cucu, A. I., Avieriței, D. A., Ponor, C. G., Cepoi, M.-R., Cucută, S., Dmour, B.-A., Costea, C. F., Botnariu, G., et al. (2026) · Life · doi:10.3390/life16030520 · Cited by 2
“These technologies allow the collection of large longitudinal datasets, which are impossible to obtain under traditional clinical conditions, and their use could enable early identification of autonomic changes and detection of diabetes-associated cardiovascular events [121,124].”
Early myopericarditis diagnosed in a 31-year-old patient using smartwatch technology: A case report
Diodato, S., Bardacci, Y., Aoufy, K. E., Belli, S., & Bambi, S. (2023) · International Emergency Nursing · doi:10.1016/j.ienj.2023.101365 · Cited by 2
Segal, G., Gueron, O., Cohn, M., Zubli, D., Hakim, H., Fizdel, B., Liber, P., Amir, H., & Barkai, G. (2024) · Journal of Clinical Medicine · doi:10.3390/jcm13051409 · Cited by 4
“In the future, advanced technologies are anticipated to enable the continuous telemetry of wearable devices, utilizing internet of things (IoT) for the purpose of monitoring the vital signs of patients in their homes [44,45].”
BackgroundOn the design and development of a handheld electrocardiogram device in a clinical setting
Zepeda-Echavarria, A., Arntz, N. C. M. R., Westra, A. H., van Schelven, L. J., Euwe, F. E., Noordmans, H. J., Vessies, M. B., van de Leur, R. R., Hassink, R. J., Wildbergh, T. X., et al. (2024) · Frontiers in Digital Health · doi:10.3389/fdgth.2024.1403457 · Cited by 2
“To address these challenges, the integration of home-based medical devices has gained traction, particularly in ECG monitoring (8, 9).”
BackgroundAdvanced sensors for implantable devices
Çalışır, M., Özgür, E., & Deni̇zli̇, A. (2025) · Elsevier eBooks · doi:10.1016/b978-0-443-24790-3.00024-7 · Cited by 2
A Pilot Study of the Home-Based 12-Lead Electrocardiogram in Clinical Practice
Disrud, L. W., Swain, W. H., Davison, H. N., Gosse, T., Kubler, M. M., Harmon, D., Friedman, P. A., Noseworthy, P. A., & Kashou, A. H. (2025) · Mayo Clinic Proceedings Innovations Quality & Outcomes · doi:10.1016/j.mayocpiqo.2025.100598 · Cited by 3
Implementation of Intelligent IoT
Nair, A. K., John, C., & Sahoo, J. (2022) · Lecture notes on data engineering and communications technologies · doi:10.1007/978-3-030-90618-4_2 · Cited by 2
Buhr, L., Kaufmann, P. L. M., & Jörß, K. (2022) · JMIR Cardio · doi:10.2196/34959 · Cited by 2
Romano, C., Presti, D. L., Silvestri, S., Nusca, A., Ussia, G. P., Schena, E., & Massaroni, C. (2025) · International Workshop on Biomedical Applications, Technologies and Sensors (BATS) · doi:10.1109/bats67559.2025.11336181 · Cited by 1
“While they should not be considered a substitute for comprehensive multi-lead ECG diagnostics, they help bridge the gap between conventional short-term assessment and the need for extended monitoring [24].”
Smartphone-Based Data Collection in Ophthalmology
Raber, F. P., Gerbutavicius, R., Wolf, A., & Kortuem, K. (2020) · Klinische Monatsblätter für Augenheilkunde · doi:10.1055/a-1232-4250 · Cited by 1
“Measurement readings such as heart rate and energy consumption, rest and sleep phases, and with new devices even heart rhythm and ECG; respiratory rate; blood oxygenation; skin temperature; skin circulation; skin sweat; stress; and exposure to addictive substances can be evaluated [13].”
BackgroundAn Apple Watch Dashboard for HiGHmed Heart Insufficency Patients
Smieszek, M., Kindermann, A., Amr, A., Meder, B., & Dieterich, C. (2021) · Studies in health technology and informatics · doi:10.3233/shti210553 · Cited by 1
“The study “Wearables in cardiology: Here to stay” shows that there is user interest to use wearables not only for fitness tracking but also in medical practice [5].”
BackgroundDevaki, V., Lakshmanan, M. K., & Jayanthi, T. (2023) · International Conference on Artificial Intelligence and Signal Processing (AISP) · doi:10.1109/aisp57993.2023.10134818 · Cited by 1
“These findings show that wrist-worn PPG HR values during activity should be considered cautiously [12].”
BackgroundFuture Techniques and Perspectives on Implanted and Wearable Heart Failure Detection Devices
Chowdhury, M. E. H., Khandaker, A., Qiblawey, Y., Haque, F., Ezeddin, M., Rahman, T., Ibtehaz, N., & Islam, K. R. (2022) · Wiley eBooks · doi:10.1002/9781119813040.ch13 · Cited by 1
Kim, S. H., Lee, Y., Hwang, S. Y., Shin, J., Kim, C. K., & Park, J. (2020) · Healthcare · doi:10.3390/healthcare8030312
Enplegu, interés eta diruari buruzko teoria orokorra
Keynes, J. M. (1998) · Dialnet (Universidad de la Rioja)
Detektion von Vorhofflimmern mit Wearables
Zink, M. D., Eberhardt, F., Napp, A., & Gramlich, M. (2022) · Kardiologie up2date · doi:10.1055/a-1355-0610
Nava, A. (2022) · RiuNet (Universitat Politècnica de València) · doi:10.4995/thesis/10251/184778
Takami, M., Fukuzawa, K., Kiuchi, K., Takemoto, M., Nakamura, T., Sakai, J., Yatomi, A., Nakasone, K., Sonoda, Y., Yamamoto, K., et al. (2024) · doi:10.22541/au.170664888.84521681/v1
Lins, G. H. A., Camelo, E. M. A., Lins, C. S., Montenegro, M. L. V., Rodrigues, W. D. M., Júnior, E. A. C., de Oliveira, F. H. C., & Dutra, R. F. (2024) · Caderno Pedagógico · doi:10.54033/cadpedv21n12-066
Umweltfaktoren und Schlaganfall – Vervollständigung präventiver Maßnahmen
Braadt, L., Ertl, M., & Naumann, M. (2025) · DGNeurologie · doi:10.1007/s42451-025-00754-8
Metadata
- Authors
- Dagher, L., Shi, H., Zhao, Y., & Marrouche, N. F.
- Affiliations
- Tulane University (US)
- Corresponding author
- Marrouche, Nassir F.
- Venue
- Heart Rhythm
- Publisher
- Elsevier BV
- Published
- 2020-05
- Volume
- 17
- Issue
- 5
- Pages
- 889-895
- ISSN
- 1547-5271 (ISSN-L)
- OpenAlex
- W3018275759
- Cited by
- 107
- References
- 58
- Citations by year
- 2026: 5 · 2025: 18 · 2024: 17 · 2023: 27 · 2022: 22 · 2021: 13 · 2020: 4
- FWCI
- 1.38
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Heart Rhythm (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
- Health Sciences › Health Professions › General Health Professions › Mobile Health and mHealth Applications
- Keywords
- wearable devices, smartwatches, atrial fibrillation detection, photoplethysmography, pulse waveform, continuous cardiac monitoring, stroke prevention, artificial intelligence, cardiovascular management, physician-patient relationship
- MeSH terms
- Wearable Electronic Devices, Artificial Intelligence, Atrial Fibrillation, Cardiology, Electrocardiography, Equipment Design, Humans, Monitoring, Physiologic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review