CoChat

Layered biocompatible pH-responsive antibacterial composite film based on HNT/PLGA/chitosan for controlled release of minocycline as burn wound dressing

Mohebali, Alireza, Abdouss, Majid · 2020 · International Journal of Biological Macromolecules
Cited by 70

The DOI matches its Crossref record; 59 of the 59 references it cites were found in a registry or an index.

Abstract

In the present study, a promising pH-responsive wound dressing was prepared. Halloysite nanotube (HNT) composites were modified with different concentration of both poly (lactic-co-glycolic acid) (PLGA) and chitosan (CS) through the Layer-by-Layer (LbL) strategy for targeted and controlled drug delivery of minocycline (MC). The resulting composites were characterized by FT-IR, XRD, zeta-potential, TGA, FE-SEM and TEM studies. Studying the biodegradability, water uptake, photostability, and water vapor transmission of resulting composites revealed that the composite film absorbed wound secretions, did not degrade, and penetrated properly to wound during the treatment. The results of protein adsorption showed that the optimized composite (C40P60MNT) was blood-compatible. Studying the release profile of the drug showed pH-responsive behavior that was fitted with Korsmeyer-Peppas kinetic model. In-vitro antibacterial testing showed that the C40P60MNT sample had an acceptable effect on the inhibition of gram-positive and gram-negative bacteria. In wound healing test (in-vivo studies), this MC loaded composite film showed faster healing of the burn wound in rat compare to the control sample. Due to the characteristics of the optimized sample, it can be considered as a promising candidate for pH-responsive drug delivery in the treatment of chronic burn wounds.

Overview

Integrity signals

Registry

Crossref · 10.1016/j.ijbiomac.2020.09.004

Cites

59 of 59 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

This paper’s full text isn’t openly available, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Citations

Cites

Show all 59 references

Research works printed but not linked: 8

  1. Cartotto, 2017, Topical antimicrobial agents for pediatric burns, Burns & Trauma, 5
  2. Kircik, 2020, Formulation and profile of FMX101 4% minocycline topical foam for the treatment of acne vulgaris, J Clin Aesthet Dermatol, 13, 14
  3. Yao, 2014, Local delivery of minocycline-loaded PEG-PLA nanoparticles for the enhanced treatment of periodontitis in dogs, Int. J. Nanomedicine, 9, 3963
  4. Zhang, 2019, In vivo assessments of minocycline combined hyaluronic acid-mediated ultrasound therapy of infected wound in rats, bioRxiv
  5. Wang, 2011, Recent advances of chitosan nanoparticles as drug carriers, Int. J. Nanomedicine, 6, 765
  6. Yulun, 2012, Photodegradation of tetracyclines compound in aqueous solution under different light irradiation [J], Chinese Journal of Environmental Engineering, 8
  7. Xu, 2016, Controlled water vapor transmission rate promotes wound-healing via wound re-epithelialization and contraction enhancement, Sci. Rep., 6
  8. Singhvi, 2011, In-vitro drug release characterization models, Int J Pharm Stud Res, 2, 77

Cited by

Metadata

Authors
Mohebali, A., & Abdouss, M.
Venue
International Journal of Biological Macromolecules
Publisher
Elsevier BV
Published
2020-12
Volume
164
Pages
4193-4204
ISSN
0141-8130
Cited by
70
References
59
Language
en

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.