On the effect of geometrical imperfections and defects on the fatigue strength of cellular lattice structures additively manufactured via Selective Laser Melting
Open accessThe DOI matches its Crossref record; 36 of the 36 references it cites were found in a registry or an index.
Abstract
Abstract Porous structures have great potential in the biomedical field because, compared to traditional fully dense implants, prostheses with a porous structure show reduced stress shielding and improved osseo-integration. Selective Laser Melting (SLM) made possible to obtain metallic cellular materials with highly complex structures characterized by a wide range of cell morphologies that allow to finely tune the mechanical properties of the implant. Nevertheless, there are still several issues to address: among others, detrimental residual stresses and the discrepancy between the as-designed and the manufactured geometry. Micro X-ray computed tomography (µCT) combined with the Finite Elements (FE) method permits to carry out in-depth investigations on the effect of the number and severity of defects on the mechanical properties. In the current study, the results of fatigue and quasi-static tests were compared with FE calculations based on the as-designed geometry and on the as-built geometry reconstructed from µCT scans. Both the elastic modulus and the fatigue resistance resulted strongly correlated with the number and severity of defects. Moreover, predictions of the mechanical properties based only on the as-designed geometry were shown not to be accurate. The importance of considering the limitations in accuracy of the manufacturing technique when designing load bearing lattice structures was highlighted.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cellular solids structure and properties
Gibson, L. J., Ashby, M. F., et al. (1997) · Cited by 9,172
Cellular solids: Structure and properties
Wolcott, M. P. (1990) · Materials Science and Engineering: A · doi:10.1016/0921-5093(90)90295-e · Cited by 5,926
Metal Fabrication by Additive Manufacturing Using Laser and Electron Beam Melting Technologies
Murr, L. E., Gaytan, S. M., Ramirez, D. A., Martinez, E., Hernandez, J., Amato, K. N., Shindo, P. W., Medina, F. R., & Wicker, R. B. (2012) · Journal of Materials Science & Technology · doi:10.1016/s1005-0302(12)60016-4 · Cited by 1,686
Leuders, S., Thöne, M., Riemer, A., Niendorf, T., Tröster, T., Richard, H. A., & Maier, H. J. (2013) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2012.11.011 · Cited by 1,475
Fabrication methods of porous metals for use in orthopaedic applications
Ryan, G., Pandit, A., & Apatsidis, D. P. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.12.002 · Cited by 1,391
Taniguchi, N., Fujibayashi, S., Takemoto, M., Sasaki, K., Otsuki, B., Nakamura, T., Matsushita, T., Kokubo, T., & Matsuda, S. (2016) · Materials Science and Engineering: C · doi:10.1016/j.msec.2015.10.069 · Cited by 960
Mechanical Behavior of Materials
Huda, Z. (2021) · Mechanical engineering series · doi:10.1007/978-3-030-84927-6 · Cited by 912
Mechanical Behavior of Materials
(2005) · Materials Today · doi:10.1016/s1369-7021(05)71163-9 · Cited by 840
Mechanical evaluation of porous titanium (Ti6Al4V) structures with electron beam melting (EBM)
Parthasarathy, J., Starly, B., Raman, S., & Christensen, A. (2010) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2009.10.006 · Cited by 816
Murr, L. E., Gaytan, S. M., Medina, F., Lopez, H., Martinez, E., Machado, B. I., Hernandez, D. H., Martinez, L., Lopez, M. I., Wicker, R. B., et al. (2010) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2010.0010 · Cited by 636
Tan, X. P., Tan, Y. J., Chow, C. S. L., Tor, S. B., & Yeong, W. Y. (2017) · Materials Science and Engineering: C · doi:10.1016/j.msec.2017.02.094 · Cited by 514
Liu, L., Kamm, P., García-Moreno, F., Banhart, J., & Pasini, D. (2017) · Journal of the Mechanics and Physics of Solids · doi:10.1016/j.jmps.2017.07.003 · Cited by 513 · cited 1×
“For instance, Liu et al. (2017) showed that FE models based on the as-built geometry of cellular lattices acquired via uCT scans can explain the mismatch between the mechanical properties measured experimentally and those predicted with simulations based on the as-designed geometry.”
MethodWauthle, R., Vrancken, B., Beynaerts, B., Jorissen, K., Schrooten, J., Kruth, J.-P., & Van Humbeeck, J. (2015) · Additive Manufacturing · doi:10.1016/j.addma.2014.12.008 · Cited by 463
Van Bael, S., Kerckhofs, G., Moesen, M., Pyka, G., Schrooten, J., & Kruth, J. P. (2011) · Materials Science and Engineering: A · doi:10.1016/j.msea.2011.06.045 · Cited by 452
Qiu, C., Yue, S., Adkins, N. J. E., Ward, M., Hassanin, H., Lee, P. D., Withers, P. J., & Attallah, M. M. (2015) · Materials Science and Engineering: A · doi:10.1016/j.msea.2015.01.031 · Cited by 385
Fatigue behavior of porous biomaterials manufactured using selective laser melting
Amin Yavari, S., Wauthle, R., van der Stok, J., Riemslag, A. C., Janssen, M., Mulier, M., Kruth, J. P., Schrooten, J., Weinans, H., & Zadpoor, A. A. (2013) · Materials Science and Engineering: C · doi:10.1016/j.msec.2013.08.006 · Cited by 357
Van Hooreweder, B., Apers, Y., Lietaert, K., & Kruth, J.-P. (2017) · Acta Biomaterialia · doi:10.1016/j.actbio.2016.10.005 · Cited by 318
Sing, S. L., Wiria, F. E., & Yeong, W. Y. (2018) · Robotics and Computer-Integrated Manufacturing · doi:10.1016/j.rcim.2017.06.006 · Cited by 302
Benedetti, M., Fontanari, V., Bandini, M., Zanini, F., & Carmignato, S. (2018) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2017.10.021 · Cited by 297
Self-citationRealistic loads for testing hip implants
Bergmann, G., Graichen, F., Rohlmann, A., Bender, A., Heinlein, B., Duda, G. N., Heller, M. O., & Morlock, M. M. (2010) · Bio-Medical Materials and Engineering · doi:10.3233/bme-2010-0616 · Cited by 285
Pyka, G., Kerckhofs, G., Papantoniou, I., Speirs, M., Schrooten, J., & Wevers, M. (2013) · Materials · doi:10.3390/ma6104737 · Cited by 251
Benedetti, M., Torresani, E., Leoni, M., Fontanari, V., Bandini, M., Pederzolli, C., & Potrich, C. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.03.024 · Cited by 248
Self-citationCompression‐compression fatigue of selective electron beam melted cellular titanium (Ti‐6Al‐4V)
Hrabe, N. W., Heinl, P., Flinn, B., Körner, C., & Bordia, R. K. (2011) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.31901 · Cited by 203
Porosity testing methods for the quality assessment of selective laser melted parts
Wits, W. W., Carmignato, S., Zanini, F., & Vaneker, T. H. J. (2016) · CIRP Annals · doi:10.1016/j.cirp.2016.04.054 · Cited by 190
Self-citationHip Implant Design With Three-Dimensional Porous Architecture of Optimized Graded Density
Wang, Y., Arabnejad, S., Tanzer, M., & Pasini, D. (2018) · Journal of Mechanical Design · doi:10.1115/1.4041208 · Cited by 185
Dallago, M., Fontanari, V., Torresani, E., Leoni, M., Pederzolli, C., Potrich, C., & Benedetti, M. (2018) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2017.11.044 · Cited by 182
Self-citationBagheri, Z. S., Melancon, D., Liu, L., Johnston, R. B., & Pasini, D. (2017) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2016.04.041 · Cited by 162
Fatigue behavior of Ti-6Al-4V cellular structures fabricated by additive manufacturing technique
Ren, D., Li, S., Wang, H., Hou, W., Hao, Y., Jin, W., Yang, R., Misra, R. D. K., & Murr, L. E. (2018) · Journal of Material Science and Technology · doi:10.1016/j.jmst.2018.09.066 · Cited by 158
Hedayati, R., Hosseini‐Toudeshky, H., Sadighi, M., Aghdam, M. M., & ZADPOOR, A. A. (2015) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2015.11.017 · Cited by 145
Mullen, L., Stamp, R. C., Fox, P., Jones, E., Ngo, C., & Sutcliffe, C. J. (2009) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.31504 · Cited by 138
Titanium Alloys for Biomedical Applications
Niinomi, M., & Boehlert, C. J. (2015) · Springer series in biomaterials science and engineering · doi:10.1007/978-3-662-46836-4_8 · Cited by 120
Benedetti, M., & Santus, C. (2019) · International Journal of Fatigue · doi:10.1016/j.ijfatigue.2018.12.020 · Cited by 90
Self-citationde Krijger, J., Rans, C. D., Hooreweder, B. V., Lietaert, K., Pouran, B., & ZADPOOR, A. A. (2016) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2016.11.022 · Cited by 83
Deviation Modeling and Shape Transformation in Design for Additive Manufacturing
Zhu, Z., Anwer, N., & Mathieu, L. (2017) · Procedia CIRP · doi:10.1016/j.procir.2017.01.023 · Cited by 67
Dallago, M., Benedetti, M., Luchin, V., & Fontanari, V. (2017) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2016.12.026 · Cited by 22
Self-citationBasic design rules of unit cells for additive manufactured lattice structures
Kessler, J., Bâlc, N., Gebhardt, A., & Abbas, K. (2017) · MATEC Web of Conferences · doi:10.1051/matecconf/201713702005 · Cited by 14
Cited by
Sanaei, N., & Fatemi, A. (2021) · Progress in Materials Science · doi:10.1016/j.pmatsci.2020.100724 · Cited by 1,029
Benedetti, M., du Plessis, A., Ritchie, R. O., Dallago, M., Razavi, N., & Berto, F. (2021) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2021.100606 · Cited by 788
Self-citationdu Plessis, A., Yadroitsava, I., & Yadroitsev, I. (2020) · Materials & Design · doi:10.1016/j.matdes.2019.108385 · Cited by 712
Properties and applications of additively manufactured metallic cellular materials: A review
du Plessis, A., Razavi, N., Benedetti, M., Murchio, S., Leary, M., Watson, M., Bhate, D., & Berto, F. (2022) · Progress in Materials Science · doi:10.1016/j.pmatsci.2021.100918 · Cited by 623
Self-citationWu, Y., Fang, J., Wu, C., Li, C., Sun, G., & Li, Q. (2023) · International Journal of Mechanical Sciences · doi:10.1016/j.ijmecsci.2023.108102 · Cited by 440
Metadata
- Authors
- Dallago, M., Winiarski, B., Zanini, F., Carmignato, S., & Benedetti, M.
- Venue
- International Journal of Fatigue
- Publisher
- Elsevier BV
- Published
- 2019-07
- Volume
- 124
- Pages
- 348-360
- ISSN
- 0142-1123 (ISSN-L)
- OpenAlex
- W2921833870
- Cited by
- 222
- References
- 36
- FWCI
- 12.14
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.