Successful application of large microneedle patches by human volunteers
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
We describe, for the first time, the design, production and evaluation of large microneedle patches. Such systems, based on 16 individual microneedle arrays (needle height 600 μm), were prepared from aqueous blends of 15% w/w Gantrez ® S97 and 7.5% w/w poly(ethyleneglycol) 10,000 Da. Ester-based crosslinking was confirmed by FTIR and mechanical strength was good. Insertion depths in a validated skin model were approximately 500 μm. Ten human volunteers successfully self-inserted the microneedles of these larger patches in their skin, following appropriate instruction, as confirmed by transepidermal water loss measurements. The mean insertion depth ranged between 300 and 450 μm over the area of the large patches. That this was not significantly different to a single unit MN patch self-applied by the same volunteers is encouraging. Microneedle patch sizes much larger than the 1–2 cm 2 will be required if this technology is to be successfully translated to clinic for delivery of drug substances. The work described here suggests that use of such larger patches by patients can be successful, potentially opening up the possibility for a significant expansion of the size of the market for transdermal drug delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Microfabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346 · cited 3×
“This is an open access arti on vaccines (Henry et al., 1998; McGrath et al., 2011).”
BackgroundLarrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964 · cited 6×
“During this time, a vast number of types of MN arrays, including solid metal and silicon, dissolving polymeric, hollow and hydrogel-forming MN have all been investigated as delivery systems (Larrañeta et al., 2016c; Prausnitz 2004; Tuan-Mahmood et al., 2013).”
BackgroundInfluentialSelf-citationHydrogel‐Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery
Donnelly, R. F., Singh, T. R. R., Garland, M. J., Migalska, K., Majithiya, R., McCrudden, C. M., Kole, P. L., Mahmood, T. M. T., McCarthy, H. O., & Woolfson, A. D. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200864 · Cited by 727 · cited 6×
“OCT was used, as described previously (Donnelly et al., 2012a; Donnelly et al., 2014a), to study microneedle penetration depth and micropore diameter and to determine whether all 16 arrays of a large patch had successfully penetrated the stratum corneum.”
BackgroundMethodInfluentialSelf-citationA proposed model membrane and test method for microneedle insertion studies
Larrañeta, E., Moore, J., Vicente-Pérez, E. M., González-Vázquez, P., Lutton, R., Woolfson, A. D., & Donnelly, R. F. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.05.042 · Cited by 603 · cited 6×
“Parafilm(1) M (PF) film was used as a skin simulant for MN insertion studies, as described previously (Larrañeta et al., 2014).”
MethodInfluentialSelf-citationMicroneedles for intradermal and transdermal drug delivery
Tuan-Mahmood, T.-M., McCrudden, M. T. C., Torrisi, B. M., McAlister, E., Garland, M. J., Singh, T. R. R., & Donnelly, R. F. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.05.005 · Cited by 468 · cited 4×
“Some of the benefits include the ability to painlessly administer the active pharmaceutical ingredient, bypass of hepatic first pass metabolism and extension of the range of types of drug that can be delivered intradermally and transdermally (Tuan-Mahmood et al., 2013).”
BackgroundInfluentialSelf-citationDonnelly, R. F., McCrudden, M., Alkilani, A. Z., Larrañeta, E., McAlister, E., Courtenay, A. J., Kearney, M., Singh, T. R. R., McCarthy, H. O., Kett, V. L., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111547 · Cited by 370 · cited 6×
“…work has suggested that dissolving MN arrays and hydrogel-forming MN arrays can both potentially be used for the delivery of high drug doses sufficient to elicit therapeutic effects in humans, providing patch size is appropriate (Donnelly et al., 2014b; McCrudden et al., 2014).”
BackgroundMethodInfluentialSelf-citationMicroneedles: A New Frontier in Nanomedicine Delivery
Larrañeta, E., McCrudden, M. T. C., Courtenay, A. J., & Donnelly, R. F. (2016) · Pharmaceutical Research · doi:10.1007/s11095-016-1885-5 · Cited by 339 · cited 1×
“Ester-based crosslinking was confirmed by FTIR and mechanical strength was good.”
BackgroundSelf-citationMcCrudden, M., Alkilani, A. Z., McCrudden, C. M., McAlister, E., McCarthy, H. O., Woolfson, A. D., & Donnelly, R. F. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.02.007 · Cited by 269 · cited 2×
“…work has suggested that dissolving MN arrays and hydrogel-forming MN arrays can both potentially be used for the delivery of high drug doses sufficient to elicit therapeutic effects in humans, providing patch size is appropriate (Donnelly et al., 2014b; McCrudden et al., 2014).”
BackgroundSelf-citationMicroneedle‐Mediated Transdermal and Intradermal Drug Delivery
Donnelly, R. F., Singh, T. R. R., Morrow, D. I. J., & Woolfson, A. D. (2012) · Wiley eBooks · doi:10.1002/9781119959687 · Cited by 226
Self-citationMicroneedle applications in improving skin appearance
McCrudden, M. T. C., McAlister, E., Courtenay, A. J., González‐Vázquez, P., Raj Singh, T. R., & Donnelly, R. F. (2015) · Experimental Dermatology · doi:10.1111/exd.12723 · Cited by 224 · cited 2×
“MN with applications in improving skin appearance are now available commercially, though it is notable that these are not approved drug products (McCrudden et al., 2015b).”
BackgroundSelf-citationBirchall, J. C., Clemo, R., Anstey, A., & John, D. N. (2011) · Pharmaceutical Research · doi:10.1007/s11095-010-0101-2 · Cited by 182 · cited 2×
“Indeed, a number of studies examining patient usability (Birchall et al., 2011; Donnelly et al., 2014a; Vicente-Pérez et al., 2016), scaled-up manufacture and quality control testing (Larrañeta et al.”
BackgroundLutton, R. E. M., Moore, J., Larrañeta, E., Ligett, S., Woolfson, A. D., & Donnelly, R. F. (2015) · Drug Delivery and Translational Research · doi:10.1007/s13346-015-0237-z · Cited by 161 · cited 3×
“The needles themselves exhibited good mechanical properties, as they did not break during direct compression and showed deeper insertion profiles than those reported by us previously (Lutton et al., 2015b), possibly due to the move from conical to pyramidal needle designs.”
BackgroundMethodSelf-citationConsiderations in the sterile manufacture of polymeric microneedle arrays
McCrudden, M., Alkilani, A. Z., Courtenay, A. J., McCrudden, C. M., McCloskey, B., Walker, C., Alshraiedeh, N., Lutton, R. E. M., Gilmore, B., Woolfson, A. D., et al. (2014) · Drug Delivery and Translational Research · doi:10.1007/s13346-014-0211-1 · Cited by 153
Self-citationKearney, M., Caffarel–Salvador, E., Fallows, S. J., McCarthy, H. O., & Donnelly, R. F. (2016) · European Journal of Pharmaceutics and Biopharmaceutics · doi:10.1016/j.ejpb.2016.03.026 · Cited by 144 · cited 1×
“Our own work has focused strongly on delivery of therapeuticallyrelevant doses of drugs using MN patches (Donnelly et al., 2012a, 2014b; Kearney et al., 2016).”
BackgroundSelf-citationA novel scalable manufacturing process for the production of hydrogel-forming microneedle arrays
Lutton, R. E. M., Larrañeta, E., Kearney, M., Boyd, P., Woolfson, A. D., & Donnelly, R. F. (2015) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2015.08.049 · Cited by 107 · cited 1×
“…work has suggested that dissolving MN arrays and hydrogel-forming MN arrays can both potentially be used for the delivery of high drug doses sufficient to elicit therapeutic effects in humans, providing patch size is appropriate (Donnelly et al., 2014b; McCrudden et al., 2014).”
Self-citationLarrañeta, E., Lutton, R. E. M., Brady, A. J., Vicente-Perez, E. M., Woolfson, A. D., Thakur, R. R. S., & Donnelly, R. F. (2015) · Macromolecular Materials and Engineering · doi:10.1002/mame.201500016 · Cited by 102 · cited 2×
“…patient usability (Birchall et al., 2011; Donnelly et al., 2014a; Vicente-Pérez et al., 2016), scaled-up manufacture and quality control testing (Larrañeta et al., 2015, 2016b; Lutton et al., 2015b), sterile production (McCrudden et al., 2015a) and regulatory considerations (Lutton et al.,…”
BackgroundMethodSelf-citationFuture of the transdermal drug delivery market – have we barely touched the surface?
Watkinson, A. C., Kearney, M., Quinn, H. L., Courtenay, A. J., & Donnelly, R. F. (2015) · Expert Opinion on Drug Delivery · doi:10.1517/17425247.2016.1130034 · Cited by 91 · cited 1×
“Successful translation of such a technology would clearly create a significant opportunity for industry in terms of expanding the size of the transdermal market, which has now been in stagnation for several years, with few new drug candidates in the pipeline (Watkinson et al., 2016).”
BackgroundSelf-citationVicente-Perez, E. M., Quinn, H. L., McAlister, E., O’Neill, S., Hanna, L., Barry, J. G., & Donnelly, R. F. (2016) · Pharmaceutical Research · doi:10.1007/s11095-016-2032-z · Cited by 72 · cited 4×
“Indeed, a number of studies examining patient usability (Birchall et al., 2011; Donnelly et al., 2014a; Vicente-Pérez et al., 2016), scaled-up manufacture and quality control testing (Larrañeta et al.”
BackgroundMethodInfluentialSelf-citation
Cited by
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Larrañeta, E., Henry, M., Irwin, N. J., Trotter, J., Perminova, A. A., & Donnelly, R. F. (2018) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2017.12.015 · Cited by 269
Self-citationLong-acting reversible contraception by effervescent microneedle patch
Li, W., Tang, J., Terry, R. N., Li, S., Brunie, A., Callahan, R. L., Noel, R. K., Rodríguez, C. A., Schwendeman, S. P., & Prausnitz, M. R. (2019) · Science Advances · doi:10.1126/sciadv.aaw8145 · Cited by 248
Metadata
- Authors
- Ripolin, A., Quinn, J., Larrañeta, E., Vicente-Perez, E. M., Barry, J., & Donnelly, R. F.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 521
- Issue
- 1-2
- Pages
- 92-101
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2587861573
- Cited by
- 193
- References
- 19
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.