Successful application of large microneedle patches by human volunteers
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
We describe, for the first time, the design, production and evaluation of large microneedle patches. Such systems, based on 16 individual microneedle arrays (needle height 600 μm), were prepared from aqueous blends of 15% w/w Gantrez ® S97 and 7.5% w/w poly(ethyleneglycol) 10,000 Da. Ester-based crosslinking was confirmed by FTIR and mechanical strength was good. Insertion depths in a validated skin model were approximately 500 μm. Ten human volunteers successfully self-inserted the microneedles of these larger patches in their skin, following appropriate instruction, as confirmed by transepidermal water loss measurements. The mean insertion depth ranged between 300 and 450 μm over the area of the large patches. That this was not significantly different to a single unit MN patch self-applied by the same volunteers is encouraging. Microneedle patch sizes much larger than the 1–2 cm 2 will be required if this technology is to be successfully translated to clinic for delivery of drug substances. The work described here suggests that use of such larger patches by patients can be successful, potentially opening up the possibility for a significant expansion of the size of the market for transdermal drug delivery.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Microneedles for transdermal drug delivery
Prausnitz, M. R. (2004) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2003.10.023 · Cited by 1,521
Microfabricated Microneedles: A Novel Approach to Transdermal Drug Delivery
Henry, S., McAllister, D. V., Allen, M. G., & Prausnitz, M. R. (1998) · Journal of Pharmaceutical Sciences · doi:10.1021/js980042+ · Cited by 1,346 · cited 3×
“This is an open access arti on vaccines (Henry et al., 1998; McGrath et al., 2011).”
BackgroundLarrañeta, E., Lutton, R. E. M., Woolfson, A. D., & Donnelly, R. F. (2016) · Materials Science and Engineering: R: Reports · doi:10.1016/j.mser.2016.03.001 · Cited by 964 · cited 6×
“During this time, a vast number of types of MN arrays, including solid metal and silicon, dissolving polymeric, hollow and hydrogel-forming MN have all been investigated as delivery systems (Larrañeta et al., 2016c; Prausnitz 2004; Tuan-Mahmood et al., 2013).”
BackgroundInfluentialSelf-citationHydrogel‐Forming Microneedle Arrays for Enhanced Transdermal Drug Delivery
Donnelly, R. F., Singh, T. R. R., Garland, M. J., Migalska, K., Majithiya, R., McCrudden, C. M., Kole, P. L., Mahmood, T. M. T., McCarthy, H. O., & Woolfson, A. D. (2012) · Advanced Functional Materials · doi:10.1002/adfm.201200864 · Cited by 727 · cited 6×
“OCT was used, as described previously (Donnelly et al., 2012a; Donnelly et al., 2014a), to study microneedle penetration depth and micropore diameter and to determine whether all 16 arrays of a large patch had successfully penetrated the stratum corneum.”
BackgroundMethodInfluentialSelf-citationA proposed model membrane and test method for microneedle insertion studies
Larrañeta, E., Moore, J., Vicente-Pérez, E. M., González-Vázquez, P., Lutton, R., Woolfson, A. D., & Donnelly, R. F. (2014) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2014.05.042 · Cited by 603 · cited 6×
“Parafilm(1) M (PF) film was used as a skin simulant for MN insertion studies, as described previously (Larrañeta et al., 2014).”
MethodInfluentialSelf-citationMicroneedles for intradermal and transdermal drug delivery
Tuan-Mahmood, T.-M., McCrudden, M. T. C., Torrisi, B. M., McAlister, E., Garland, M. J., Singh, T. R. R., & Donnelly, R. F. (2013) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2013.05.005 · Cited by 468 · cited 4×
“Some of the benefits include the ability to painlessly administer the active pharmaceutical ingredient, bypass of hepatic first pass metabolism and extension of the range of types of drug that can be delivered intradermally and transdermally (Tuan-Mahmood et al., 2013).”
BackgroundInfluentialSelf-citationDonnelly, R. F., McCrudden, M., Alkilani, A. Z., Larrañeta, E., McAlister, E., Courtenay, A. J., Kearney, M., Singh, T. R. R., McCarthy, H. O., Kett, V. L., et al. (2014) · PLoS ONE · doi:10.1371/journal.pone.0111547 · Cited by 370 · cited 6×
“…work has suggested that dissolving MN arrays and hydrogel-forming MN arrays can both potentially be used for the delivery of high drug doses sufficient to elicit therapeutic effects in humans, providing patch size is appropriate (Donnelly et al., 2014b; McCrudden et al., 2014).”
BackgroundMethodInfluentialSelf-citationMicroneedles: A New Frontier in Nanomedicine Delivery
Larrañeta, E., McCrudden, M. T. C., Courtenay, A. J., & Donnelly, R. F. (2016) · Pharmaceutical Research · doi:10.1007/s11095-016-1885-5 · Cited by 339 · cited 1×
“Ester-based crosslinking was confirmed by FTIR and mechanical strength was good.”
BackgroundSelf-citationMcCrudden, M., Alkilani, A. Z., McCrudden, C. M., McAlister, E., McCarthy, H. O., Woolfson, A. D., & Donnelly, R. F. (2014) · Journal of Controlled Release · doi:10.1016/j.jconrel.2014.02.007 · Cited by 269 · cited 2×
“…work has suggested that dissolving MN arrays and hydrogel-forming MN arrays can both potentially be used for the delivery of high drug doses sufficient to elicit therapeutic effects in humans, providing patch size is appropriate (Donnelly et al., 2014b; McCrudden et al., 2014).”
BackgroundSelf-citationMicroneedle‐Mediated Transdermal and Intradermal Drug Delivery
Donnelly, R. F., Singh, T. R. R., Morrow, D. I. J., & Woolfson, A. D. (2012) · Wiley eBooks · doi:10.1002/9781119959687 · Cited by 226
Self-citation
Cited by
Accessing analytes in biofluids for peripheral biochemical monitoring
Heikenfeld, J., Jajack, A., Feldman, B., Granger, S. W., Gaitonde, S., Begtrup, G., & Katchman, B. A. (2019) · Nature Biotechnology · doi:10.1038/s41587-019-0040-3 · Cited by 758
Aldawood, F. K., Andar, A., & Desai, S. (2021) · Polymers · doi:10.3390/polym13162815 · Cited by 499
Opportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Larrañeta, E., Henry, M., Irwin, N. J., Trotter, J., Perminova, A. A., & Donnelly, R. F. (2018) · Carbohydrate Polymers · doi:10.1016/j.carbpol.2017.12.015 · Cited by 269
Self-citationLong-acting reversible contraception by effervescent microneedle patch
Li, W., Tang, J., Terry, R. N., Li, S., Brunie, A., Callahan, R. L., Noel, R. K., Rodríguez, C. A., Schwendeman, S. P., & Prausnitz, M. R. (2019) · Science Advances · doi:10.1126/sciadv.aaw8145 · Cited by 248
Larrañeta, E., Imízcoz, M., Toh, J. X., Irwin, N. J., Ripolin, A., Perminova, A., Domínguez-Robles, J., Rodríguez, A., & Donnelly, R. F. (2018) · ACS Sustainable Chemistry & Engineering · doi:10.1021/acssuschemeng.8b01371 · Cited by 247
Self-citationMultifunctional Smart Skin Adhesive Patches for Advanced Health Care
Hwang, I., Kim, H. N., Seong, M., Lee, S., Kang, M., Yi, H., Bae, W. G., Kwak, M. K., & Jeong, H. E. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201800275 · Cited by 227
Transdermal microneedles for the programmable burst release of multiple vaccine payloads
Tran, K. T. M., Gavitt, T. D., Farrell, N. J., Curry, E. J., Mara, A. B., Patel, A., Brown, L., Kilpatrick, S., Piotrowska, R., Mishra, N., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00650-4 · Cited by 227
Permana, A. D., Tekko, I. A., McCrudden, M. T. C., Anjani, Q. K., Ramadon, D., McCarthy, H. O., & Donnelly, R. F. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2019.10.004 · Cited by 213
“In addition, in our previous study involving human volunteers, the application of MNs was found to be pain-free [29].”
BackgroundSelf-citationRetractedGonzález-Vázquez, P., Larrañeta, E., McCrudden, M. T. C., Jarrahian, C., Rein-Weston, A., Quintanar-Solares, M., Zehrung, D., McCarthy, H., Courtenay, A. J., & Donnelly, R. F. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.07.032 · Cited by 201
“Transient mild erythema was observed after removing the patches and, in line with previous publications, the erythema disappears quickly after MN removal [53,54].”
ResultSelf-citationThe Role of 3D Printing Technology in Microengineering of Microneedles
Detamornrat, U., McAlister, E., Hutton, A. R. J., Larrañeta, E., & Donnelly, R. F. (2022) · Small · doi:10.1002/smll.202106392 · Cited by 199
Self-citationVora, L. K., Sabri, A. H., McKenna, P. E., Himawan, A., Hutton, A. R. J., Detamornrat, U., Paredes, A. J., Larrañeta, E., & Donnelly, R. F. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00108-7 · Cited by 193
Self-citationTekko, I. A., Chen, G., Domínguez-Robles, J., Thakur, R. R. S., Hamdan, I. M. N., Vora, L., Larrañeta, E., McElnay, J. C., McCarthy, H. O., Rooney, M., et al. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2020.119580 · Cited by 186
“Nevertheless, we would expect such a patch size is still very feasible based on the study which has been done in our group [79].”
BackgroundSelf-citationTekko, I. A., Permana, A. D., Vora, L., Hatahet, T., McCarthy, H. O., & Donnelly, R. F. (2020) · European Journal of Pharmaceutical Sciences · doi:10.1016/j.ejps.2020.105469 · Cited by 186
Self-citationVora, L. K., Donnelly, R. F., Larrañeta, E., González-Vázquez, P., Thakur, R. R. S., & Vavia, P. R. (2017) · Journal of Controlled Release · doi:10.1016/j.jconrel.2017.10.005 · Cited by 184
“These completely rely on subcutaneous or intramuscular injections in clinical setting while MN arrays can be easily self-administered by the patient [40-42].”
BackgroundSelf-citationMicroneedle Patch-Mediated Treatment of Bacterial Biofilms
Xu, J., Danehy, R., Cai, H., Ao, Z., Pu, M., Nusawardhana, A., Rowe-Magnus, D., & Guo, F. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b02578 · Cited by 174
A practical guide to the development of microneedle systems – In clinical trials or on the market
Lee, K. J., Jeong, S. S., Roh, D. H., Kim, D. Y., Choi, H.-K., & Lee, E. H. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118778 · Cited by 173
Vaccination into the Dermal Compartment: Techniques, Challenges, and Prospects
Hettinga, J., & Carlisle, R. (2020) · Vaccines · doi:10.3390/vaccines8030534 · Cited by 72
Metadata
- Authors
- Ripolin, A., Quinn, J., Larrañeta, E., Vicente-Perez, E. M., Barry, J., & Donnelly, R. F.
- Venue
- International Journal of Pharmaceutics
- Publisher
- Elsevier BV
- Published
- 2017-04
- Volume
- 521
- Issue
- 1-2
- Pages
- 92-101
- ISSN
- 0378-5173 (ISSN-L)
- OpenAlex
- W2587861573
- Cited by
- 193
- References
- 19
- FWCI
- 9.88
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.