The DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
In vitro approaches to assess the hazard of nanomaterials
Open accessAbstract
The rapid development of engineered nanomaterials demands for a fast and reliable assessment of their health hazard potential. A plethora of experimental approaches have been developed and are widely employed in conventional toxicological approaches. However, the specific properties of nanomaterials such as smaller size but larger surface area, and high catalytic reactivity and distinctive optical properties compared to their respective bulk entities, often disable a straightforward use of established in vitro approaches. Herein, we provide an overview of the current state-of the art nanomaterial hazard assessment strategies using in vitro approaches. This perspective has been developed based on a thorough review of over 200 studies employing such methods to assess the biological response upon exposure to a diverse array of nanomaterials. The majority of the studies under review has been, but not limited to, engaged in the European 7th Framework Programme for Research and Technological Development and published in the last five years. Based on the most widely used methods and/or the most relevant biological endpoints, we have provided some general recommendations on the use of the selected approaches which would the most closely mimic realistic exposure scenarios as well as enabling to yield fast, reliable and reproducible data on the nanomaterial-cell response in vitro. In addition, the applicability of the approaches to translate in vitro outcomes to leverage those of in vivo studies has been proposed. It is finally suggested that an improved comprehension of the approaches with its limitations used for nanomaterials' hazard assessment in vitro will improve the interpretation of the existing nanotoxicological data as well as underline the basic principles in understanding interactions of engineered nanomaterials at a cellular level; this all is imperative for their safe-by-design strategies, and should also enable subsequent regulatory approvals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Poland, C. A., Duffin, R., Kinloch, I., Maynard, A., Wallace, W. A. H., Seaton, A., Stone, V., Brown, S., MacNee, W., & Donaldson, K. (2008) · Nature Nanotechnology · doi:10.1038/nnano.2008.111 · Cited by 2,645
Monopoli, M. P., Walczyk, D., Campbell, A., Elia, G., Lynch, I., Baldelli Bombelli, F., & Dawson, K. A. (2011) · Journal of the American Chemical Society · doi:10.1021/ja107583h · Cited by 1,835
A Human Disease Model of Drug Toxicity–Induced Pulmonary Edema in a Lung-on-a-Chip Microdevice
Huh, D., Leslie, D. C., Matthews, B. D., Fraser, J. P., Jurek, S., Hamilton, G. A., Thorneloe, K. S., McAlexander, M. A., & Ingber, D. E. (2012) · Science Translational Medicine · doi:10.1126/scitranslmed.3004249 · Cited by 993
Limbach, L. K., Li, Y., Grass, R. N., Brunner, T. J., Hintermann, M. A., Muller, M., Gunther, D., & Stark, W. J. (2005) · Environmental Science & Technology · doi:10.1021/es051043o · Cited by 779 · cited 2×
“Thus, deposition of NMs concentration/dose onto the per cell surface is the dominant factor determining the rate of uptake and not particle number NM concentration per volume or total surface area of the material (Limbach et al., 2005; Teeguarden et al., 2007).”
BackgroundNanotoxicology: An Interdisciplinary Challenge
Krug, H. F., & Wick, P. (2011) · Angewandte Chemie International Edition · doi:10.1002/anie.201001037 · Cited by 556 · cited 1×
“This has to be considered regardless of the fact that the maximum effect (100% cell death) cannot always be achieved as the administration of too high doses of NMs could cause interferences with the assays (Krug and Wick, 2011; Stone et al., 2009).”
BackgroundNanoparticle toxicity by the gastrointestinal route: evidence and knowledge gaps
Bergin, I. L., & Witzmann, F. A. (2013) · International Journal of Biomedical Nanoscience and Nanotechnology · doi:10.1504/ijbnn.2013.054515 · Cited by 412 · cited 2×
“release of potentially toxic ions and/or other constituents (Bergin and Witzmann, 2013; Braakhuis et al., 2014).”
BackgroundHarush-Frenkel, O., Rozentur, E., Benita, S., & Altschuler, Y. (2008) · Biomacromolecules · doi:10.1021/bm700535p · Cited by 405
Estimating the effective density of engineered nanomaterials for in vitro dosimetry
DeLoid, G., Cohen, J. M., Darrah, T., Derk, R., Rojanasakul, L., Pyrgiotakis, G., Wohlleben, W., & Demokritou, P. (2014) · Nature Communications · doi:10.1038/ncomms4514 · Cited by 327
The “Sweet” Side of the Protein Corona: Effects of Glycosylation on Nanoparticle–Cell Interactions
Wan, S., Kelly, P. M., Mahon, E., Stöckmann, H., Rudd, P. M., Caruso, F., Dawson, K. A., Yan, Y., & Monopoli, M. P. (2015) · ACS Nano · doi:10.1021/nn506060q · Cited by 223
Wiemann, M., Vennemann, A., Sauer, U. G., Wiench, K., Ma-Hock, L., & Landsiedel, R. (2016) · Journal of Nanobiotechnology · doi:10.1186/s12951-016-0164-2 · Cited by 152
Cited by
EFSA Scientific Committee, Hardy, A., Benford, D., Halldorsson, T., Jeger, M. J., Knutsen, H. K., More, S., Naegeli, H., Noteborn, H., Ockleford, C., et al. (2018) · EFSA Journal · doi:10.2903/j.efsa.2018.5327 · Cited by 416
EFSA Scientific Committee, More, S., Bampidis, V., Benford, D., Bragard, C., Halldorsson, T., Hernández‐Jerez, A., Hougaard Bennekou, S., Koutsoumanis, K., Lambré, C., et al. (2021) · EFSA Journal · doi:10.2903/j.efsa.2021.6768 · Cited by 395
The toxicity of nanoparticles and their interaction with cells: an in vitro metabolomic perspective
Awashra, M., & Młynarz, P. (2023) · Nanoscale Advances · doi:10.1039/d2na00534d · Cited by 319
Hesler, M., Aengenheister, L., Ellinger, B., Drexel, R., Straskraba, S., Jost, C., Wagner, S., Meier, F., von Briesen, H., Büchel, C., et al. (2019) · Toxicology in Vitro · doi:10.1016/j.tiv.2019.104610 · Cited by 291
Domingues, C., Santos, A., Alvarez-Lorenzo, C., Concheiro, A., Jarak, I., Veiga, F., Barbosa, I., Dourado, M., & Figueiras, A. (2022) · ACS Nano · doi:10.1021/acsnano.2c00128 · Cited by 235
Metadata
- Authors
- Drasler, B., Sayre, P., Steinhäuser, K. G., Petri-Fink, A., & Rothen-Rutishauser, B.
- Venue
- NanoImpact
- Publisher
- Elsevier BV
- Published
- 2017-10
- Volume
- 8
- Pages
- 99-116
- ISSN
- 2452-0748 (ISSN-L)
- OpenAlex
- W2753429148
- Cited by
- 245
- References
- 10
- FWCI
- 8.81
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.