Cited by 158Cardiac Arrhythmias and TreatmentsCardiovascular Syncope and Autonomic DisordersCardiac electrophysiology and arrhythmias

The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.

Recurrent Unexplained Palpitations (RUP) Study

Open access

Abstract

Objectives The aim of the study was to compare the diagnostic yield and the costs of implantable loop recorder (ILR) with those of the conventional strategy in patients with unexplained palpitations.Background In patients with unexplained palpitations, especially in those with infrequent symptoms, the conventional strategy, including short-term ambulatory electrocardiogram (ECG) monitoring and electrophysiological study, sometimes fails to establish a diagnosis.Methods We studied 50 patients with infrequent (< or =1 episode/month), sustained (>1 min) palpitations. Before enrollment, patients had a negative initial evaluation, including history, physical examination, and ECG. Patients were randomized either to conventional strategy (24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an external recorder, and electrophysiological study) (n = 24) or to ILR implantation with 1-year monitoring (n = 26). Hospital costs of the 2 strategies were calculated.Results A diagnosis was obtained in 5 patients in the conventional strategy group, and in 19 subjects in the ILR group (21% vs. 73%, p < 0.001). Despite the higher initial cost, the cost per diagnosis in the ILR group was lower than in the conventional strategy group (euro 3,056 +/- euro 363 vs. euro 6,768 +/- euro 6,672, p = 0.012).Conclusions In subjects without severe heart disease and with infrequent palpitations, ILR is a safe and more cost-effective diagnostic approach than conventional strategy.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacc.2007.02.036

Cites

9 of 9 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 9 references

Cited by

Sorted by citations

See all 158

Metadata

Authors
Giada, F., Gulizia, M., Francese, M., Croci, F., Santangelo, L., Santomauro, M., Occhetta, E., Menozzi, C., & Raviele, A.
Affiliations
  • Federico II University Hospital (IT)
  • Azienda Ospedaliero Universitaria Maggiore della Carita (IT)
Corresponding author
Raviele, Antonio
Venue
Journal of the American College of Cardiology
Publisher
Elsevier BV
Published
2007-05
Volume
49
Issue
19
Pages
1951-1956
ISSN
0735-1097 (ISSN-L)
OpenAlex
W70889386
Cited by
158
References
9
Citations by year
2026: 3 · 2025: 3 · 2024: 2 · 2023: 9 · 2022: 9 · 2021: 15 · 2020: 6 · 2019: 7 · 2018: 16 · 2017: 11 · 2016: 7 · 2015: 10 · 2014: 11 · 2013: 13 · 2012: 5
FWCI
5.38
Type
journal article
Language
en
Open access
Locations
  • Journal of the American College of Cardiology (publishedVersion)
  • PubMed (publishedVersion)
  • Archivio Istituzionale della Ricerca - Università degli Studi della Campania "Luigi Vanvitelli" (submittedVersion)
Funders
Medtronic
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
Keywords
implantable loop recorder, diagnostic yield, cost-effectiveness, Holter monitoring, electrophysiological study, arrhythmia diagnosis
MeSH terms
Adult, Aged, Arrhythmias, Cardiac, Cost-Benefit Analysis, Electrodes, Implanted, Female, Humans, Male, Middle Aged, Prospective Studies, Recurrence, Sensitivity and Specificity, Time Factors, Electrocardiography, Ambulatory

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review