The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Recurrent Unexplained Palpitations (RUP) Study
Open accessAbstract
Objectives The aim of the study was to compare the diagnostic yield and the costs of implantable loop recorder (ILR) with those of the conventional strategy in patients with unexplained palpitations.Background In patients with unexplained palpitations, especially in those with infrequent symptoms, the conventional strategy, including short-term ambulatory electrocardiogram (ECG) monitoring and electrophysiological study, sometimes fails to establish a diagnosis.Methods We studied 50 patients with infrequent (< or =1 episode/month), sustained (>1 min) palpitations. Before enrollment, patients had a negative initial evaluation, including history, physical examination, and ECG. Patients were randomized either to conventional strategy (24-h Holter recording, a 4-week period of ambulatory ECG monitoring with an external recorder, and electrophysiological study) (n = 24) or to ILR implantation with 1-year monitoring (n = 26). Hospital costs of the 2 strategies were calculated.Results A diagnosis was obtained in 5 patients in the conventional strategy group, and in 19 subjects in the ILR group (21% vs. 73%, p < 0.001). Despite the higher initial cost, the cost per diagnosis in the ILR group was lower than in the conventional strategy group (euro 3,056 +/- euro 363 vs. euro 6,768 +/- euro 6,672, p = 0.012).Conclusions In subjects without severe heart disease and with infrequent palpitations, ILR is a safe and more cost-effective diagnostic approach than conventional strategy.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, clinical characteristics of the patient, such as age, presence of heart disease, and ECG abnormalities, do not always allow the physician to identify a priori those cases in which palpitations are caused by clinically significant rhythm disorders.8,47,48,52 -54”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [52]
In the citing paper
“Finally, a small percentage of patients with palpitations of unknown origin have major bradyarrhythmic disorders, such as severe sinus bradycardia and paroxysmal advanced atrioventricular block.52,71”
From Management of patients with palpitations: a position paper from the European Heart Rhythm Association (2011) · cites this paper as [52]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Krahn, A. D., Klein, G. J., Yee, R., & Skanes, A. C. (2001) · Circulation · doi:10.1161/01.cir.104.1.46 · Cited by 405
Guidelines for clinical intracardiac electrophysiological and catheter ablation procedures
Zipes, D. P., Dimarco, J., Gillette, P. C., Jackman, W. M., Myerburg, R. J., Rahimtoola, S. H., Ritchie, J. L., Cheitlin, M. D., Garson, A., Gibbons, R. J., et al. (1995) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(95)80037-h · Cited by 279
Crawford, M. H., Bernstein, S. J., Deedwania, P. C., DiMarco, J. P., Ferrick, K. J., Garson, A., Green, L. A., Greene, H. L., Silka, M. J., Stone, P. H., et al. (1999) · Circulation · doi:10.1161/01.cir.100.8.886 · Cited by 215
Evaluation and outcomes of patients with palpitations
Weber, B. E., & Kapoor, W. N. (1996) · The American Journal of Medicine · doi:10.1016/s0002-9343(97)89451-x · Cited by 196
Evaluation of patients with palpitations
Zimetbaum, P., & Josephson, M. E. (1998) · New England Journal of Medicine · doi:10.1056/nejm199805073381907 · Cited by 172
Cost implications of testing strategy in patients with syncope
Krahn, A. D., Klein, G. J., Yee, R., Hoch, J. S., & Skanes, A. C. (2003) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(03)00659-4 · Cited by 170
The Evolving Role of Ambulatory Arrhythmia Monitoring in General Clinical Practice
Zimetbaum, P. J., & Josephson, M. E. (1999) · Annals of Internal Medicine · doi:10.7326/0003-4819-130-10-199905180-00020 · Cited by 139
Ermiş, C., Zhu, A. X., Pham, S., Li, J. M., Guerrero, M., Vrudney, A., Hiltner, L., Lü, F., Sakaguchi, S., Lurie, K. G., et al. (2003) · The American Journal of Cardiology · doi:10.1016/s0002-9149(03)00889-0 · Cited by 50
Paroxysmal Tachycardia in Children and Teenagers with Normal Sinus Rhythm and Without Heart Disease
Brembilla-Perrot, B., Marçon, F., Bosser, G., Lucron, H., Houriez, P., Claudon, O., HOLBAN, I., & Blangy, H. (2001) · Pacing and Clinical Electrophysiology · doi:10.1046/j.1460-9592.2001.00041.x · Cited by 23
Cited by
Sorted by citations
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Indications for the use of diagnostic implantable and external ECG loop recorders
Task Force members, Brignole, M., Vardas, P., Hoffman, E., Huikuri, H., Moya, A., Ricci, R., Sulke, N., Wieling, W., EHRA Scientific Documents Committee, et al. (2009) · Europace · doi:10.1093/europace/eup097 · Cited by 362
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.043 · Cited by 337
Ambulatory Arrhythmia Monitoring: Choosing the Right Device
Zimetbaum, P., & Goldman, A. (2010) · Circulation · doi:10.1161/circulationaha.109.925610 · Cited by 209
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000627 · Cited by 161
Raviele, A., Giada, F., Bergfeldt, L., Blanc, J. J., Blomstrom-Lundqvist, C., Mont, L., Morgan, J. M., Raatikainen, M. J. P., Steinbeck, G., Viskin, S., et al. (2011) · Europace · doi:10.1093/europace/eur130 · Cited by 149
Self-citationKusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2018) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.036 · Cited by 138
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Implantable loop recorder in clinical practice
Bisignani, A., Bonis, S. D., Mancuso, L., Ceravolo, G., & Bisignani, G. (2018) · Journal of Arrhythmia · doi:10.1002/joa3.12142 · Cited by 116
Locati, E. T., Moya, A., Oliveira, M., Tanner, H., Willems, R., Lunati, M., & Brignole, M. (2016) · Europace · doi:10.1093/europace/euv311 · Cited by 95
Remote Monitoring Alert Burden
O’Shea, C., Middeldorp, M. E., Hendriks, J., Brooks, A. G., Lau, D. H., Emami, M., Mishima, R. S., Thiyagarajah, A., Feigofsky, S. A., Gopinathannair, R., et al. (2020) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2020.08.029 · Cited by 82
The 2020 ESC Guidelines on the Diagnosis and Management of Atrial Fibrillation
Kotalczyk, A., Lip, G. Y. H., & Calkins, H. G. (2021) · Arrhythmia & Electrophysiology Review · doi:10.15420/aer.2021.07 · Cited by 78
Does this patient with palpitations have a cardiac arrhythmia?
Thavendiranathan, P. (2009) · JAMA · doi:10.1001/jama.2009.1673 · Cited by 75
Hendrikx, T., Rosenqvist, M., Wester, P. O., Sandström, H., & Hörnsten, R. (2014) · BMC Cardiovascular Disorders · doi:10.1186/1471-2261-14-41 · Cited by 73
The Reveal LINQ insertable cardiac monitor
Tomson, T. T., & Passman, R. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2014.953059 · Cited by 72
Italian Cardiological Guidelines for Sports Eligibility in Athletes with Heart Disease
Biffi, A., Delise, P., Zeppilli, P., Giada, F., Pelliccia, A., Penco, M., Casasco, M., Colonna, P., D’Andrea, A., D’Andrea, L., et al. (2013) · Journal of Cardiovascular Medicine · doi:10.2459/jcm.0b013e32835f6a21 · Cited by 71
Self-citationMaines, M., Zorzi, A., Tomasi, G., Angheben, C., Catanzariti, D., Piffer, L., & Greco, M. D. (2017) · EP Europace · doi:10.1093/europace/eux187 · Cited by 66
Effectiveness of remote monitoring in the management of syncope and palpitations
Furukawa, T., Maggi, R., Bertolone, C., Ammirati, F., Santini, M., Ricci, R., Giada, F., & Brignole, M. (2011) · Europace · doi:10.1093/europace/euq503 · Cited by 57
Self-citationLocati, E. H., Vecchi, A. M., Vargiu, S., Cattafi, G., & Lunati, M. (2013) · EP Europace · doi:10.1093/europace/eut337 · Cited by 54
Cardiac arrhythmias during long‐duration spaceflights
Anzai, T., Frey, M., & Nogami, A. (2013) · Journal of Arrhythmia · doi:10.1016/j.joa.2013.07.009 · Cited by 52
Ambulatory ECG Monitoring in Atrial Fibrillation Management
Rosero, S. Z., Kutyifa, V., Olshansky, B., & Zaręba, W. (2013) · Progress in Cardiovascular Diseases · doi:10.1016/j.pcad.2013.10.001 · Cited by 51
Efficacy of diagnostic tools for detecting cardiac arrhythmias: systematic literature search
Hoefman, E., Bindels, P., & van Weert, H. C. P. M. (2010) · Netherlands Heart Journal · doi:10.1007/s12471-010-0831-0 · Cited by 50
Golden Standard or Obsolete Method? Review of ECG Applications in Clinical and Experimental Context
Stračina, T., Ronzhina, M., Ředina, R., & Novàkovâ, M. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2022.867033 · Cited by 56
Carrington, M., Providencia, R. A., Chahal, C. A. A., Ricci, F., Epstein, A. E., Gallina, S., Fedorowski, A., Sutton, R., & Khanji, M. Y. (2022) · European Heart Journal Open · doi:10.1093/ehjopen/oeac072 · Cited by 43
Insertable cardiac monitors: current indications and devices
Sakhi, R., Theuns, D. A. M. J., Szili‐Törok, T., & Yap, S. (2018) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1557046 · Cited by 43
New Directions in Cardiac Arrhythmia Management: Present Challenges and Future Solutions
Nattel, S., Andrade, J. G., Macle, L., Rivard, L., Dyrda, K., Mondesert, B. A., & Khairy, P. (2014) · Canadian Journal of Cardiology · doi:10.1016/j.cjca.2014.09.027 · Cited by 37
Recommendations for the use of electrophysiological study: Update 2018
Mureşan, L., Cismaru, G. L., Martins, R. P., Bataglia, A., Roşu, R., Puiu, M., Guşetu, G., Mada, R. O., Muresan, C., Ispas, D. R., et al. (2018) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2018.09.002 · Cited by 37
The Role of Implantable Cardiac Monitors in Atrial Fibrillation Management
Ciconte, G., Giacopelli, D., & Pappone, C. (2017) · Journal of Atrial Fibrillation · doi:10.4022/jafib.1590 · Cited by 36
Lacunza-Ruiz, F. J., Moya-Mitjans, A., Martínez-Alday, J., Barón-Esquivias, G., Ruiz-Granell, R., Rivas-Gándara, N., González-Enríquez, S., Leal-del-Ojo, J., F. Arcocha-Torres, M., Pérez-Villacastín, J., et al. (2013) · Circulation Journal · doi:10.1253/circj.cj-13-0201 · Cited by 34
Implantable loop recorders in the real world: a study of two Canadian centers
Ibrahim, O., Drew, D., Hayes, C. J., McIntyre, W. F., Seifer, C. M., Hopman, W. M., Glover, B. M., & Baranchuk, A. M. (2017) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-017-0294-y · Cited by 35
Mobile Health for Arrhythmia Diagnosis and Management
Baman, J. R., Mathew, D. T., Jiang, M. N., & PASSMAN, R. S. (2021) · Journal of General Internal Medicine · doi:10.1007/s11606-021-07007-w · Cited by 34
Current and Emerging Indications for Implantable Cardiac Monitors
Giada, F., Bertaglia, E., Reimers, B., Noventa, D., & Raviele, A. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03411.x · Cited by 30
Self-citationPhilippsen, T. J., Christensen, L. S., Hansen, M. G., Dahl, J. S., & Brandes, A. (2017) · JACC. Clinical electrophysiology · doi:10.1016/j.jacep.2017.06.020 · Cited by 31
Cardiac Electronic Devices: Future Directions and Challenges
Kotalczyk, A., Kalarus, Z. F., Wright, D. J., Boriani, G., & Lip, G. Y. H. (2020) · Medical Devices Evidence and Research · doi:10.2147/mder.s245625 · Cited by 29
Performance of the New BioMonitor 2‐AF Insertable Cardiac Monitoring System: Can Better be Worse?
Lacour, P., Dang, P. L., Huemer, M., Parwani, A. S., Attanasio, P., Pieske, B. M., Boldt, L., Haverkamp, W., & Blaschke, F. (2017) · Pacing and Clinical Electrophysiology · doi:10.1111/pace.13059 · Cited by 28
Critical review of electrocardiography measurement systems and technology
Kalra, A. M., Lowe, A., & Al‐Jumaily, A. M. (2018) · Measurement Science and Technology · doi:10.1088/1361-6501/aaf2b7 · Cited by 27
Ambulatory ECG monitoring in the age of smartphones
Sanders, D. J., Ungar, L. D. J., Eskander, M., & Seto, A. H. (2019) · Cleveland Clinic Journal of Medicine · doi:10.3949/ccjm.86a.18123 · Cited by 26
Value of implantable loop recorders in patients with structural or electrical heart disease
Sakhi, R., Theuns, D. A. M. J., Bhagwandien, R. E., Michels, M., Schinkel, A. F. L., Szili‐Törok, T., Zijlstra, F., Roos‐Hesselink, J. W., & Yap, S. (2018) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-018-0354-y · Cited by 23
Cardiac monitoring for patients with palpitations
Pascual, J. F., Romero, J. C., Pérez‐Rodon, J., Benito, B., Santos‐Ortega, A., Maldonado, J., González, I. F., & Rivas‐Gándara, N. (2021) · World Journal of Cardiology · doi:10.4330/wjc.v13.i11.608 · Cited by 23
Arrocha, A., Klein, G. J., Benditt, D. G., Sutton, R., & Krahn, A. D. (2010) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2010.02857.x · Cited by 22
Clinical Approach to Patients with Palpitations
Giada, F., & Raviele, A. (2018) · Cardiac Electrophysiology Clinics · doi:10.1016/j.ccep.2018.02.010 · Cited by 21
Self-citationImplant Evaluation of an Insertable Cardiac Monitor Outside the Electrophysiology Lab Setting
PACHULSKI, R. T., Cockrell, J. L., Solomon, H., Yang, F., & Rogers, J. (2013) · PLoS ONE · doi:10.1371/journal.pone.0071544 · Cited by 20
Reinsch, N., Ruprecht, U., Buchholz, J., Diehl, R. R., Kälsch, H., & Neven, K. G. E. J. (2018) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2018.05.017 · Cited by 20
Deneke, T., Müller, P., Lawo, T., Lemke, B., Horlitz, M., Calcum, B., Bösche, L., Mügge, A., & Grewe, P. (2009) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-009-0036-7 · Cited by 20
Emerging Role of Digital Technology and Remote Monitoring in the Care of Cardiac Patients
Banchs, J. E., & Scher, D. M. (2015) · Medical Clinics of North America · doi:10.1016/j.mcna.2015.02.013 · Cited by 19
Kanjwal, K., Kanjwal, Y., Karabin, B. L., & Grubb, B. P. (2009) · International Journal of Medical Sciences · doi:10.7150/ijms.6.106 · Cited by 19
Benefits of an early management of palpitations
Clémenty, N., Fourquet, A., André, C., Bisson, A., Pierre, B., Fauchier, L., Babuty, D., & Angoulvant, D. (2018) · Medicine · doi:10.1097/md.0000000000011466 · Cited by 17
Palpitations: Evaluation in the Primary Care Setting.
Wexler, R., Pleister, A. P., & Raman, S. V. (2017) · PubMed · Cited by 16
Managing athletes with palpitations of unknown origin with an external loop recorder: A cohort study
SCIARRA, L., CAVARRETTA, E., SICILIANI, S., SETTE, A., SCARÀ, A., GRIECO, D., DE RUVO, E., PALAMÀ, Z., NESTI, M., ROMANO, S., et al. (2022) · The Journal of Sports Medicine and Physical Fitness · doi:10.23736/s0022-4707.21.12831-2 · Cited by 15
Diagnosis of Cardiac Arrhythmias
Miller, J. M., & Zipes, D. P. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-0398-6.00036-6 · Cited by 15
Efficacy And Safety Of Implantable Loop Recorder: Experience Of A Center.
Silveira, I., Sousa, M. J., Antunes, N., Silva, V. M. D. S., Roque, C., Pinheiro‐Vieira, A., Lagarto, V., Hipólito-Reis, A., Luz, A., & Torres, S. (2016) · Europe PMC (PubMed Central) · doi:10.4022/jafib.1425 · Cited by 15
Diagnostic value of implantable loop recorders in patients with unexplained syncope or palpitations
Radovanović, N. N., Pavlović, S. U., Kirćanski, B., Branković, N., Vujadinović, N., Sajic, V., Milasinovic, A., Bisenić, V., Živković, M., & Milašinović, G. (2021) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12864 · Cited by 14
Smith, A., Perdue, M., Vojnika, J., Frisch, D. R., & Pavri, B. B. (2020) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-020-00815-w · Cited by 14
Rubio, L. F., Granero, C. L., Vidal-Pérez, R., Barrios, V., & Freixa‐Pamias, R. (2023) · Revista Española de Cardiología · doi:10.1016/j.recesp.2023.07.011 · Cited by 14
New technologies for the diagnosis, treatment, and monitoring of cardiovascular diseases
Fácila, L., Granero, C. L., Vidal-Pérez, R., Barrios, V., & Freixa‐Pamias, R. (2023) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2023.07.009 · Cited by 14
Vallès, E., Martí‐Almor, J., Bazán, V., Suarez, F., Cian, D. M., Portillo, L., & Bruguera, J. (2011) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2010.12.047 · Cited by 13
Ward, F., McGovern, R., & Cotter, P. E. (2014) · Journal of Stroke and Cerebrovascular Diseases · doi:10.1016/j.jstrokecerebrovasdis.2014.07.038 · Cited by 13
Pascual, J. F., Santos‐Ortega, A., Roca‐Luque, I., Rivas‐Gándara, N., Pérez‐Rodon, J., Milà, L., David Garcia-dorado, A., & Moya‐Mitjans, À. (2018) · Revista Española de Cardiología (English Edition) · doi:10.1016/j.rec.2018.04.007 · Cited by 12
Pingitore, A., Peruzzi, M., Clarich, S. C., Palamà, Z., Sciarra, L., & Cavarretta, E. (2023) · Clinical Cardiology · doi:10.1002/clc.24073 · Cited by 11
Quan, K. J. (2019) · Medical Clinics of North America · doi:10.1016/j.mcna.2019.05.005 · Cited by 11
Outpatient approach to palpitations.
Wexler, R., Pleister, A. P., & Raman, S. V. (2011) · PubMed · Cited by 11
The Implantable Loop Recorder: Current Uses, Future Directions
Kanjwal, K., Figueredo, V. M., Karabin, B. L., & Grubb, B. P. (2011) · Cited by 10
Diagnostic yield of implantable loop recorders: Results from the Hellenic registry.
Letsas, K. P., Saplaouras, A., Mililis, P., Kariki, O., Bazoukis, G., Archontakis, S., Anagnostopoulos, I., Triantafyllou, S., Palaiodimou, L., Chatziantoniou, A., et al. (2025) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2024.05.004 · Cited by 9
Pascual, J. F., Santos‐Ortega, A., Roca‐Luque, I., Rivas‐Gándara, N., Pérez‐Rodon, J., Milà, L., David Garcia-dorado, A., & Moya‐Mitjans, À. (2018) · Revista Española de Cardiología · doi:10.1016/j.recesp.2018.04.013 · Cited by 9
Diagnosis and management of phantom tachycardias based on an electrophysiologically guided approach
Tsiachris, D., Koutagiar, I. P., Gatzoulis, K. A., Αρσένος, Π., Rigatou, A., Dilaveris, P., Sideris, S. K., Papadopoulos, A., Kritikos, A., Stefanadis, C., et al. (2016) · Hellenic Journal of Cardiology · doi:10.1016/j.hjc.2016.11.030 · Cited by 9
Chokesuwattanaskul, R., Safadi, A. R., Ip, R., Waraich, H. K., Hudson, O., & Ip, J. H. (2019) · Journal of Biomedical Science and Engineering · doi:10.4236/jbise.2019.128030 · Cited by 9
Value of Ambulatory Electrocardiographic Monitoring in Syncope
Giada, F., & Bartoletti, A. (2015) · Cardiology Clinics · doi:10.1016/j.ccl.2015.04.004 · Cited by 9
Self-citationThe implantable loop recorder and its mammographic appearance: A case based approach
Steinberger, S., & Margolies, L. R. (2017) · Clinical Imaging · doi:10.1016/j.clinimag.2017.01.006 · Cited by 8
Inappropriate Asystole Detection in Early Postoperative Phase after Loop Recorder Implantation
Bortnik, M., Occhetta, E., Magnani, A., Degiovanni, A., & Marino, P. N. (2011) · ISRN Cardiology · doi:10.5402/2011/146062 · Cited by 8
Self-citationTrends in Subcutaneous Cardiac Monitoring Technology
Kohno, R., Nantsupawat, T., & Benditt, D. G. (2018) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2018.090703 · Cited by 8
Subcutaneous cardiac rhythm monitors: state of the art review
Nadkarni, A., Devgun, J. K., Jamal, S. M., Bardales, D., Mease, J., Matto, F., Okabe, T., Daoud, E. G., & Afzal, M. R. (2021) · Expert Review of Medical Devices · doi:10.1080/17434440.2021.1935873 · Cited by 8
O’Shea, C., Brooks, A. G., Middeldorp, M. E., Harper, C., Hendriks, J., Russo, A. M., Freeman, J. V., Gopinathannair, R., Varma, N., Deering, T. F., et al. (2023) · Journal of Interventional Cardiac Electrophysiology · doi:10.1007/s10840-023-01481-4 · Cited by 7
Clinical Utility of Implantable Loop Recorders
Houmsse, M., Ishola, A., & Daoud, E. G. (2014) · Postgraduate Medicine · doi:10.3810/pgm.2014.03.2738 · Cited by 7
Current rare indications and future directions for implantable loop recorders
Wechselberger, S., Piorkowski, C., & Pohl, M. (2016) · Herzschrittmachertherapie + Elektrophysiologie · doi:10.1007/s00399-016-0475-x · Cited by 7
The mammographic appearance of the BioMonitor implantable loop recorder
Nia, E. S., Huang, M. L., Sun, S. X., Mitchell, M. P., Myatt, J. P., & Candelaria, R. P. (2020) · Clinical Imaging · doi:10.1016/j.clinimag.2020.11.051 · Cited by 6
Clinical outcomes following rhythm control for atrial fibrillation: is early better?
Kotalczyk, A., Ding, W. Y., Gupta, D., Wright, D. J., & Lip, G. Y. H. (2021) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2021.1902307 · Cited by 6
Sports and arrhythmias: a report of the International Workshop Venice Arrhythmias 2009
Giada, F., Biffi, A., Cannom, D. S., Cappato, R., Capucci, A., Corrado, D., Delise, P., Drezner, J. A., El‐Sherif, N., Estes, M., et al. (2010) · European Journal of Cardiovascular Prevention & Rehabilitation · doi:10.1097/hjr.0b013e328338a387 · Cited by 6
Self-citationAmbulatory electrocardiography: indications and devices
Sampson, M. G. (2019) · British Journal of Cardiac Nursing · doi:10.12968/bjca.2019.14.3.114 · Cited by 6
A decade of insertable cardiac monitors with remote monitoring in pediatric patients
Silvetti, M. S., Tamburri, I., Porco, L., Saputo, F. A., Mambro, C. D., Righi, D., Cazzoli, I., Cicenia, M., Campisi, M., Ravà, L., et al. (2022) · Reviews in Cardiovascular Medicine · doi:10.31083/j.rcm2301027 · Cited by 6
Emergency Management of Palpitations in the Elderly
Jamshed, N., Dubin, J. S., & ELDADAH, Z. A. (2012) · Clinics in Geriatric Medicine · doi:10.1016/j.cger.2012.10.003 · Cited by 6
P- and R-Wave Amplitude Sensed By Reveal LINQ™ Loop Recorder in Pediatric Patients
D'Souza, R., Thomas, E., Macicek, S. L., Aziz, P. F., Shivapour, J., & Snyder, C. S. (2017) · Journal of Innovations in Cardiac Rhythm Management · doi:10.19102/icrm.2017.080102 · Cited by 6
Usefulness of an Implantable Loop Recorder in Patients with Syncope of an Unknown Cause
Kang, G. H., Oh, J. H., Chun, W. J., Park, Y. H., Song, B. G., Kim, J. S., On, Y. K., Park, S., & Huh, J. (2013) · Yonsei Medical Journal · doi:10.3349/ymj.2013.54.3.590 · Cited by 6
Subcutaneouscardiac Rhythm Monitors: A Comprehensive Review
Lakkireddy, D. (2021) · Journal of Atrial Fibrillation · doi:10.4022/jafib.2387 · Cited by 5
Farré, J., Wellens, H. J. J., Campal, J. M. R., & Bénézet, J. M. (2009) · doi:10.1093/med/9780199566990.003.028 · Cited by 5
Steinberg, C., Bennett, M. T., & Krahn, A. D. (2017) · Cardiovascular medicine · doi:10.1007/978-3-319-58000-5_5 · Cited by 5
Assessment of the Patient With a Cardiac Arrhythmia
Das, M. K., & Zipes, D. P. (2013) · Elsevier eBooks · doi:10.1016/b978-1-4557-2856-5.00058-3 · Cited by 5
Assaf, A., Sakhi, R., Michels, M., Roos‐Hesselink, J. W., Verhagen, J. M. A., Bhagwandien, R. E., Szili‐Törok, T., Theuns, D. A. M. J., & Yap, S. (2021) · Open Heart · doi:10.1136/openhrt-2021-001748 · Cited by 4
Holding Area LINQ Trial (HALT)
Lee, J. J., Weitz, D. S., & Anand, R. G. (2017) · Indian Pacing and Electrophysiology Journal · doi:10.1016/j.ipej.2017.06.003 · Cited by 4
Mittal, S. (2015) · Annals of Noninvasive Electrocardiology · doi:10.1111/anec.12322 · Cited by 4
Experiencia clínica con el uso del monitor cardiaco implantable
Vanegas, D. I., Jiménez, N. J., Rincón, C. A., Hernández, M. A., & Valderrama-Barbosa, Z. (2016) · Revista Colombiana de Cardiología · doi:10.1016/j.rccar.2016.08.004 · Cited by 3
Clinical electrophysiology of the aging heart
Murray, K., Wahid, M., Alagiakrishnan, K., & Senaratne, J. M. (2022) · Expert Review of Cardiovascular Therapy · doi:10.1080/14779072.2022.2045196 · Cited by 4
Choi, Y. Y., Choi, J., Kim, Y. G., Min, K., Roh, S., Shim, J., Choi, J. S., & Kim, Y. (2022) · International Journal of Arrhythmia · doi:10.1186/s42444-022-00068-w · Cited by 4
A comparison of Atrial Fibrillation Detection Strategies After Ischemic Stroke-A Retrospective Study
Salehin, S., Muhammad, S., Rasmussen, P., Mai, S., Safder, Z., Hasan, S. M., Ghani, H. A., Zhang, Y., Salehin, S., KUO, Y.-F., et al. (2022) · Current Problems in Cardiology · doi:10.1016/j.cpcardiol.2022.101515 · Cited by 3
Cressman, S., Rheinboldt, M., Klochko, C. L., Nadig, J., & Spizarny, D. L. (2018) · Current Problems in Diagnostic Radiology · doi:10.1067/j.cpradiol.2018.05.006 · Cited by 3
Subbiah, R. N., Gula, L. J., Klein, G. J., Skanes, A. C., Yee, R. K., & Krahn, A. D. (2008) · Springer eBooks · doi:10.1007/978-1-84628-854-8_23 · Cited by 3
Enfoque semiológico de las palpitaciones
Gaviria, M. Á., Bustos, C. H., & Mora, G. (2014) · Revista de la Facultad de Medicina · doi:10.15446/revfacmed.v62n1.43779 · Cited by 3
Dudek, D., Banasiak, W., Braksator, W., Dubiel, J. S., Grodzicki, T. K., Hoffmań, P., Kuśmierczyk, M., Opolski, G., Ponikowski, P. P., Różański, J., et al. (2013) · Cardiology Journal · doi:10.5603/cj.a2019.0007 · Cited by 3
Zhou, Z., Gou, K., Luo, Z., Li, W., ZHANG, W.-Z., & Li, Y. (2014) · Experimental and Therapeutic Medicine · doi:10.3892/etm.2014.1693 · Cited by 2
The Use of an Implantable Loop Recorder in Patients With Syncope of Unknown Origin
Shin, D., Kim, J. S., Park, J. W., Yim, H. R., Kim, J., Lee, S. M., Kim, K. S., Lee, C., Jung, D. C., On, Y. K., et al. (2008) · Korean Circulation Journal · doi:10.4070/kcj.2008.38.4.205 · Cited by 2
Metadata
- Authors
- Giada, F., Gulizia, M., Francese, M., Croci, F., Santangelo, L., Santomauro, M., Occhetta, E., Menozzi, C., & Raviele, A.
- Affiliations
- Federico II University Hospital (IT)
- Azienda Ospedaliero Universitaria Maggiore della Carita (IT)
- Corresponding author
- Raviele, Antonio
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2007-05
- Volume
- 49
- Issue
- 19
- Pages
- 1951-1956
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W70889386
- Cited by
- 158
- References
- 9
- Citations by year
- 2026: 3 · 2025: 3 · 2024: 2 · 2023: 9 · 2022: 9 · 2021: 15 · 2020: 6 · 2019: 7 · 2018: 16 · 2017: 11 · 2016: 7 · 2015: 10 · 2014: 11 · 2013: 13 · 2012: 5
- FWCI
- 5.38
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of the American College of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Archivio Istituzionale della Ricerca - Università degli Studi della Campania "Luigi Vanvitelli" (submittedVersion)
- Funders
- Medtronic
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
- Keywords
- implantable loop recorder, diagnostic yield, cost-effectiveness, Holter monitoring, electrophysiological study, arrhythmia diagnosis
- MeSH terms
- Adult, Aged, Arrhythmias, Cardiac, Cost-Benefit Analysis, Electrodes, Implanted, Female, Humans, Male, Middle Aged, Prospective Studies, Recurrence, Sensitivity and Specificity, Time Factors, Electrocardiography, Ambulatory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review