The DOI matches its Crossref record; 32 of the 32 references it cites were found in a registry or an index.
Syncope Predicts the Outcome of Cardiomyopathy Patients
Open accessAbstract
Objectives The outcome of congestive heart failure (CHF) patients with syncope is understood incompletely.Background We analyzed data from patients enrolled in the SCD-HeFT (Sudden Cardiac Death Heart Failure Trial) to determine whether syncope predicted outcomes in patients with CHF.Methods We compared outcomes (and associated clinical characteristics) in patients with and without syncope enrolled in SCD-HeFT.Results In SCD-HeFT, 162 (6%) patients had syncope before randomization, 356 (14%) had syncope after randomization (similar incidence in each randomized arm), and 46 (2%) had syncope before and after randomization. A QRS duration >or=120 ms and absence of beta-blocker use predicted syncope during follow-up (hazard ratio [HR] 1.30 and 95% confidence interval [CI] 1.06 to 1.61, p = 0.014 and HR 1.25, 95% CI 1.01 to 1.56, p = 0.048, respectively). Syncope recurrence did not differ by randomization arm. However, in the implantable cardioverter-defibrillator (ICD) arm, syncope, before and after randomization, was associated with appropriate ICD discharges (HR 1.75, 95% CI 1.10 to 2.80, p = 0.019 and HR 2.91, 95% CI 1.89 to 4.47, p = 0.001, respectively). Post-randomization syncope predicted total and cardiovascular death (HR 1.41, 95% CI 1.13 to 1.76, p = 0.002 and HR 1.55, 95% CI 1.19 to 2.02, p = 0.001, respectively). The elevated relative risk of mortality for syncope versus non-syncope patients did not vary significantly across treatment arms (ICD, HR 1.54, 95% CI 1.04 to 2.27; amiodarone, HR 1.33, 95% CI 0.91 to 1.93; and placebo, HR 1.39, 95% CI 0.96 to 2.02, test for difference p = 0.86).Conclusions For CHF patients with ICDs, syncope was associated with appropriate ICD activations. Syncope was associated with increased mortality risk in SCD-HeFT regardless of treatment arm (placebo, amiodarone, or ICD).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“Although ICD may not prevent syncope recurrence in these patients, 31,348 it is indicated to reduce the risk of SCD”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [31]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“When indicated, ICD prevents SCD but it may be unable to prevent syncope due to VT recurrence. 31,348”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [31]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In patients with New York Heart Association class III–IV HF, syncope is present in 12% to 14% of patients (46,47).”
From 2017 ACC/AHA/HRS Guideline for the Evaluation and Management of Patients With Syncope (2017) · cites this paper as [46]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“Structural heart disease 25-27,31,35,36,45 and primary electrical disease 46 are major risk factors for sudden cardiac death (SCD) and overall mortality in patients with syncope.”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [31]
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Arrhythmic syncope is highly probable when the ECG shows 25-39 : • Persistent sinus bradycardia <40 b.p.m. or sinus pauses >3 s in awake state and in absence of physical training; • Mobitz II second- and third-degree AV block; • Alternating left and right BBB; • VT or rapid paroxysmal SVT;”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [31]
Experimental — accuracy not yet measured
The check wasn’t confident either way, so it gives no verdict — never disputed.
In the citing paper
“Cardiac ischaemia-related syncope is confirmed when syncope presents with evidence of acute myocardial ischaemia with or without myocardial infarction. 25-39”
From 2018 ESC Guidelines for the diagnosis and management of syncope (2018) · cites this paper as [31]
Experimental — accuracy not yet measured
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
Self-citationIncidence and Prognosis of Syncope
Soteriades, E. S., Evans, J. C., Larson, M. G., Chen, M. H., Chen, L., Benjamin, E. J., & Levy, D. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa012407 · Cited by 1,364
A Prospective Evaluation and Follow-up of Patients with Syncope
Kapoor, W. N., Karpf, M., Wieand, S., Peterson, J. R., & Levey, G. S. (1983) · New England Journal of Medicine · doi:10.1056/nejm198307283090401 · Cited by 779
AHA/ACCF Scientific Statement on the Evaluation of Syncope
Strickberger, S. A., Benson, D. W., Biaggioni, I., Callans, D. J., Cohen, M. I., Ellenbogen, K. A., Epstein, A. E., Friedman, P. A., Goldberger, J. J., Heidenreich, P. A., et al. (2006) · Circulation · doi:10.1161/circulationaha.105.170274 · Cited by 331
Shen, W. K., Decker, W. W., Smars, P. A., Goyal, D. G., Walker, A. E., Hodge, D. O., Trusty, J. M., Brekke, K. M., Jahangir, A., Brady, P. A., et al. (2004) · Circulation · doi:10.1161/01.cir.0000149236.92822.07 · Cited by 318
Syncope in advanced heart failure: high risk of sudden death regardless of origin of syncope
Middlekauff, H. R., Stevenson, W. G., Stevenson, L. W., & Saxon, L. A. (1993) · Journal of the American College of Cardiology · doi:10.1016/0735-1097(93)90724-f · Cited by 311
Risk stratification of patients with syncope
Martin, T. P., Hanusa, B. H., & Kapoor, W. N. (1997) · Annals of Emergency Medicine · doi:10.1016/s0196-0644(97)70217-8 · Cited by 285
Knight, B. P., Goyal, R., Pelosi, F., Flemming, M. A., Horwood, L. E., Morady, F., & Strickberger, S. A. (1999) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(99)00148-5 · Cited by 216
Is syncope a risk factor for poor outcomes? comparison of patients with and without syncope
Kapoor, W. N., & Hanusa, B. H. (1996) · The American Journal of Medicine · doi:10.1016/s0002-9343(95)00052-6 · Cited by 180
AHA/ACCF Scientific Statement on the Evaluation of Syncope
Strickberger, S. A., Benson, D. W., Biaggioni, I., Callans, D. J., Cohen, M. I., Ellenbogen, K. A., Epstein, A. E., Friedman, P. A., Goldberger, J. J., Heidenreich, P. A., et al. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2005.12.019 · Cited by 127
Research works printed but not linked: 2
- Racco, 2000, Long-term follow-up after syncope, Minerva Cardioangiol, 48, 69
- Poole, 2004, Analysis of implantable defibrillator shock electrograms in the Sudden Cardiac Death-Heart Failure Trial, Heart Rhythm, 1, S178
Cited by
Sorted by citations
Developed in collaboration with, European Heart Rhythm Association (EHRA), Heart Failure Association (HFA), and Heart Rhythm Society (HRS), societies, E. B. T. F., European Society of Emergency Medicine (EuSEM), European Federation of Internal Medicine (EFIM), European Union Geriatric Medicine Society (EUGMS), American Geriatrics Society (AGS), European Neurological Society (ENS), et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp298 · Cited by 2,040
Self-citation2018 ESC Guidelines for the diagnosis and management of syncope
Brignole, M., Moya, A., de Lange, F. J., Deharo, J.-C., Elliott, P. M., Fanciulli, A., Fedorowski, A., Furlan, R., Kenny, R. A., Martín, A., et al. (2018) · European Heart Journal · doi:10.1093/eurheartj/ehy037 · Cited by 1,951
Al‐Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T. M., Field, M. E., Fonarow, G. C., et al. (2018) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2017.10.054 · Cited by 1,902
Al‐Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T. M., Field, M. E., Fonarow, G. C., et al. (2017) · Circulation · doi:10.1161/cir.0000000000000549 · Cited by 777
Al‐Khatib, S. M., Stevenson, W. G., Ackerman, M. J., Bryant, W. J., Callans, D. J., Curtis, A. B., Deal, B. J., Dickfeld, T. M., Field, M. E., Fonarow, G. C., et al. (2017) · Heart Rhythm · doi:10.1016/j.hrthm.2017.10.035 · Cited by 743
Metadata
- Authors
- Olshansky, B., Poole, J. E., Johnson, G., Anderson, J., Hellkamp, A. S., Packer, D., Mark, D. B., Lee, K. L., & Bardy, G. H.
- Affiliations
- University of Iowa (US)
- University of Washington (US)
- The Seattle Institute for Cardiac Research (US)
- Duke University (US)
- Mayo Clinic (US)
- Corresponding author
- Olshansky, Brian
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2008-04
- Volume
- 51
- Issue
- 13
- Pages
- 1277-1282
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2135351378
- Cited by
- 119
- References
- 32
- Citations by year
- 2026: 2 · 2025: 2 · 2024: 1 · 2023: 3 · 2022: 2 · 2021: 3 · 2020: 5 · 2019: 1 · 2018: 11 · 2017: 20 · 2016: 2 · 2015: 9 · 2014: 7 · 2013: 14 · 2012: 8
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- bronze
- doi.org
- Licence
- Locations
- Journal of the American College of Cardiology (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institutes of Health
- Medtronic
- Topics
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiovascular Syncope and Autonomic Disorders
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Heart Failure Treatment and Management
- Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
- Keywords
- syncope, congestive heart failure, cardiomyopathy, SCD-HeFT trial, implantable cardioverter-defibrillator, mortality prediction, QRS duration, beta-blocker therapy, amiodarone, sudden cardiac death, syncope recurrence, prognostic factors, cardiovascular mortality, arrhythmic risk stratification, heart failure with reduced ejection fraction
- MeSH terms
- Adult, Amiodarone, Anti-Arrhythmia Agents, Female, Health Status, Heart Failure, Humans, Male, Middle Aged, Cardiomyopathies, Predictive Value of Tests, Prognosis, Recurrence, Risk, Risk Factors, Stroke Volume, Syncope, Time Factors, Death, Sudden, Cardiac, Treatment Outcome, Defibrillators, Implantable, Myocardial Ischemia
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review