Noninvasive Detection of Macrophage-Rich Atherosclerotic Plaque in Hyperlipidemic Rabbits Using “Positive Contrast” Magnetic Resonance Imaging
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objectives To identify macrophage-rich atherosclerotic plaque non-invasively by the combined use of systemic administration of superparamagnetic nanoparticles with magnetic resonance imaging (MRI), using a positive contrast off-resonance imaging sequence (Inversion Recovery with ON-resonant water suppression: IRON). Background The sudden rupture of macrophage-rich atherosclerotic plaques can trigger the formation of an occlusive thrombus in coronary vessels, resulting in acute myocardial infarction. Therefore, a noninvasive technique that can identify macrophage-rich plaques and thereby assist with risk stratification of patients with atherosclerosis would be of great potential clinical utility. Methods Experiments were conducted on a clinical 3T MRI scanner in seven heritable hyperlipidemic and four control rabbits. Monocrystalline iron-oxide nanoparticles (MION)-47 were administrated intravenously (two doses of 250μmol Fe/kg), and animals underwent serial IRON-MRI before injection of the nanoparticles and serially after 1, 3 and 6 days. Results After administration of MION-47, a striking signal enhancement was found in areas of plaque only in hyperlipidemic rabbits. The magnitude of enhancement on MR-images had a high correlation with the number of macrophages determined by histology (p<0.001) and allowed for the detection of macrophage-rich plaque with high accuracy (AUC=0.92, SE=0.04, 95% CI=0.84-0.96, p<0.001). No significant signal enhancement was measured in remote areas without plaque by histology and in controls without atherosclerosis. Conclusion IRON-MRI in conjunction with superparamagnetic nanoparticles is a promising approach for the noninvasive evaluation of macrophage-rich, vulnerable plaques.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A concordance correlation coefficient to evaluate reproducibility.
Lin, L. I.-K. (1989) · Biometrics · doi:10.2307/2532051 · Cited by 8,785
Global mortality, disability, and the contribution of risk factors: Global Burden of Disease Study
Murray, C. J., & Lopez, A. D. (1997) · The Lancet · doi:10.1016/s0140-6736(96)07495-8 · Cited by 4,492
Rosamond, W., Flegal, K., Friday, G., Furie, K., Go, A., Greenlund, K., Haase, N., Ho, M., Howard, V., Kissela, B., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.179918 · Cited by 3,277
Kooi, M. E., Cappendijk, V. C., Cleutjens, K. B. J. M., Kessels, A. G. H., Kitslaar, P. J. E. H. M., Borgers, M., Frederik, P. M., Daemen, M. J. A. P., & van Engelshoven, J. M. A. (2003) · Circulation · doi:10.1161/01.cir.0000068315.98705.cc · Cited by 798
Amirbekian, V., Lipinski, M. J., Briley-Saebo, K. C., Amirbekian, S., Aguinaldo, J. G. S., Weinreb, D. B., Vucic, E., Frias, J. C., Hyafil, F., Mani, V., et al. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0606281104 · Cited by 356
Trivedi, R. A., Mallawarachi, C., U-King-Im, J.-M., Graves, M. J., Horsley, J., Goddard, M. J., Brown, A., Wang, L., Kirkpatrick, P. J., Brown, J., et al. (2006) · Arteriosclerosis Thrombosis and Vascular Biology · doi:10.1161/01.atv.0000222920.59760.df · Cited by 330
Cited by
Cox, T. R., & Erler, J. T. (2011) · Disease Models & Mechanisms · doi:10.1242/dmm.004077 · Cited by 1,569
Iron Oxide Based Nanoparticles for Multimodal Imaging and Magnetoresponsive Therapy
Lee, N., Yoo, D., Ling, D., Cho, M. H., Hyeon, T., & Cheon, J. (2015) · Chemical Reviews · doi:10.1021/acs.chemrev.5b00112 · Cited by 1,005
Challenges for Molecular Magnetic Resonance Imaging
Terreno, E., Castelli, D. D., Viale, A., & Aime, S. (2010) · Chemical Reviews · doi:10.1021/cr100025t · Cited by 855
Tassa, C., Shaw, S. Y., & Weissleder, R. (2011) · Accounts of Chemical Research · doi:10.1021/ar200084x · Cited by 653
Self-citationMagnetite nanoparticles for medical MR imaging
Stephen, Z. R., Kievit, F. M., & Zhang, M. (2011) · Materials Today · doi:10.1016/s1369-7021(11)70163-8 · Cited by 432
Metadata
- Authors
- Korosoglou, G., Weiss, R. G., Kedziorek, D. A., Walczak, P., Gilson, W. D., Schär, M., Sosnovik, D. E., Kraitchman, D. L., Boston, R. C., Bulte, J. W. M., Weissleder, R., & Stuber, M.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2008-08
- Volume
- 52
- Issue
- 6
- Pages
- 483-491
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2041848158
- Cited by
- 118
- References
- 6
- FWCI
- 12.42
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive Detection of Macrophage-Rich Atherosclerotic Plaque in Hyperlipidemic Rabbits Using “Positive Contrast” Magnetic Resonance Imaging. https://app.cochat.ai/papers/10.1016/j.jacc.2008.03.063
- The paper
- Korosoglou, G., Weiss, R. G., Kedziorek, D. A., Walczak, P., Gilson, W. D., Schär, M., Sosnovik, D. E., Kraitchman, D. L., Boston, R. C., Bulte, J. W. M., Weissleder, R., & Stuber, M. (2008). Noninvasive Detection of Macrophage-Rich Atherosclerotic Plaque in Hyperlipidemic Rabbits Using “Positive Contrast” Magnetic Resonance Imaging. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2008.03.063
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.