Repolarization and Activation Restitution Near Human Pulmonary Veins and Atrial Fibrillation Initiation
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
Objectives To study mechanisms to explain why single premature atrial complexes (PACs) from the pulmonary veins (PV) may initiate human atrial fibrillation (AF). Background Theoretically, single PACs may initiate AF if the rate-response of action potential duration (APD restitution) has slope > 1. However, human left atrial APD restitution and its relationship to AF have not been studied. We hypothesized that APD restitution slope > 1 near PVs explains the initiation of clinical AF. Methods We studied 27 patients with paroxysmal and persistent (n=13) AF. We advanced monophasic action potential catheters trans-septally to superior PVs. Restitution was plotted as APD of progressively early PACs against their diastolic interval (DI) from prior beats. Activation time restitution was measured using the time from the pacing artifact to each PAC. Results Compared to paroxysmal AF, patients with persistent AF had shorter left atrial APD and ERP (p=0.01). In paroxysmal AF, maximum left atrial APD restitution slope was 1.5±0.4; and 12/13 patients had slope > 1 (p<0.001). In persistent AF, PACs encountered prolonged activation for a wider range of beats than paroxysmal AF (p=0.01), that prolonged DI and flattened APD restitution (slope 0.7±0.2; p<0.001); no patient had APD restitution slope > 1. A single PAC produced AF in 5 patients; in all, APD restitution slope > 1 caused extreme APD oscillations after the PAC, then AF. Conclusions In patients with paroxysmal AF, maximum APD restitution slope > 1 near the PVs enables single PACs to initiate AF. However, patients with persistent AF exhibit marked dynamic activation delay near PVs that flattens APD restitution. Studies should determine how regional APD and conduction dynamics contribute to the substrates of persistent AF.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Franz, M. R., Karasik, P. L., Li, C., Moubarak, J., & Chavez, M. (1997) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(97)00385-9 · Cited by 301
Cited by
Pathophysiological mechanisms of atrial fibrillation: a translational appraisal
Schotten, U., Verheule, S., Kirchhof, P., & Goette, A. (2011) · Physiological Reviews · doi:10.1152/physrev.00031.2009 · Cited by 1,273
Treatment of Atrial Fibrillation by the Ablation of Localized Sources
Narayan, S. M., Krummen, D. E., Shivkumar, K., Clopton, P., Rappel, W.-J., & Miller, J. M. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.05.022 · Cited by 1,117
Self-citationHuman Atrial Action Potential and Ca 2+ Model: Sinus Rhythm and Chronic Atrial Fibrillation
Grandi, E., Pandit, S. V., Voigt, N., Workman, A. J., Dobrev, D., Jalife, J., & Bers, D. M. (2011) · Circulation Research · doi:10.1161/circresaha.111.253955 · Cited by 365
NARAYAN, S. M., KRUMMEN, D. E., & RAPPEL, W. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2012.02332.x · Cited by 332
Self-citationKirchhof, P., Bax, J., Blomstrom-Lundquist, C., Calkins, H., Camm, A. J., Cappato, R., Cosio, F., Crijns, H., Diener, H.-C., Goette, A., et al. (2009) · European Heart Journal · doi:10.1093/eurheartj/ehp235 · Cited by 202
Repolarization Alternans Reveals Vulnerability to Human Atrial Fibrillation
Narayan, S. M., Franz, M. R., Clopton, P., Pruvot, E. J., & Krummen, D. E. (2011) · Circulation · doi:10.1161/circulationaha.110.977827 · Cited by 190
Self-citationMunger, T. M., Dong, Y.-X., Masaki, M., Oh, J. K., Mankad, S. V., Borlaug, B. A., Asirvatham, S. J., Shen, W.-K., Lee, H.-C., Bielinski, S. J., et al. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.03.042 · Cited by 189
“(18) made a novel finding that an action potential duration restitution slope 1 near the PVs enables Figure 4 ERP Measurement”
BackgroundNarayan, S. M., Wright, M., Derval, N., Jadidi, A., Forclaz, A., Nault, I., Miyazaki, S., Sacher, F., Bordachar, P., Clémenty, J., et al. (2011) · Heart Rhythm · doi:10.1016/j.hrthm.2010.10.020 · Cited by 187
Self-citationCalcium in the Pathophysiology of Atrial Fibrillation and Heart Failure
Denham, N. C., Pearman, C. M., Caldwell, J. L., Madders, G. W. P., Eisner, D. A., Trafford, A. W., & Dibb, K. M. (2018) · Frontiers in Physiology · doi:10.3389/fphys.2018.01380 · Cited by 175
“Reflecting these different possibilities, while increasing SERCA by gene transfer in the failing ventricle is anti-arrhythmic (Lyon et al., 2011), overexpressing SERCA in mouse atria promotes cellular correlates of AF (Nassal et al., 2015).”
BackgroundCorrado, C., Williams, S., Karim, R., Plank, G., O’Neill, M., & Niederer, S. (2018) · Medical Image Analysis · doi:10.1016/j.media.2018.04.005 · Cited by 50
Metadata
- Authors
- Narayan, S. M., Kazi, D., Krummen, D. E., & Rappel, W.-J.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2008-10
- Volume
- 52
- Issue
- 15
- Pages
- 1222-1230
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W186539893
- Cited by
- 133
- References
- 1
- FWCI
- 5.06
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.