The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Safety and Efficacy of the Totally Subcutaneous Implantable Defibrillator
Open accessAbstract
BACKGROUND: The entirely subcutaneous implantable cardioverter-defibrillator (S-ICD) is the first implantable defibrillator that avoids placing electrodes in or around the heart. Two large prospective studies (IDE [S-ICD System IDE Clinical Investigation] and EFFORTLESS [Boston Scientific Post Market S-ICD Registry]) have reported 6-month to 1-year data on the S-ICD. OBJECTIVES: The objective of this study was to evaluate the safety and efficacy of the S-ICD in a large diverse population. METHODS: Data from the IDE and EFFORTLESS studies were pooled. Shocks were independently adjudicated, and complications were measured with a standardized classification scheme. Enrollment date quartiles were used to assess event rates over time. RESULTS: Eight hundred eighty-two patients who underwent implantation were followed for 651±345 days. Spontaneous ventricular tachyarrhythmia (VT)/ventricular fibrillation (VF) events (n=111) were treated in 59 patients; 100 (90.1%) events were terminated with 1 shock, and 109 events (98.2%) were terminated within the 5 available shocks. The estimated 3-year inappropriate shock rate was 13.1%. Estimated 3-year, all-cause mortality was 4.7% (95% confidence interval: 0.9% to 8.5%), with 26 deaths (2.9%). Device-related complications occurred in 11.1% of patients at 3 years. There were no electrode failures, and no S-ICD-related endocarditis or bacteremia occurred. Three devices (0.3%) were replaced for right ventricular pacing. The 6-month complication rate decreased by quartile of enrollment (Q1: 8.9%; Q4: 5.5%), and there was a trend toward a reduction in inappropriate shocks (Q1: 6.9% Q4: 4.5%). CONCLUSIONS: The S-ICD demonstrated high efficacy for VT/VF. Complications and inappropriate shock rates were reduced consistently with strategic programming and as operator experience increased. These data provide further evidence for the safety and efficacy of the S-ICD. (Boston Scientific Post Market S-ICD Registry [EFFORTLESS]; NCT01085435; S-ICD® System IDE Clinical Study; NCT01064076).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Bardy, G. H., Lee, K. L., Mark, D. B., Poole, J. E., Packer, D. L., Boineau, R., Domanski, M., Troutman, C., Anderson, J., Johnson, G., et al. (2005) · New England Journal of Medicine · doi:10.1056/nejmoa043399 · Cited by 6,552
(1997) · New England Journal of Medicine · doi:10.1056/nejm199711273372202 · Cited by 3,232
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,027
Reduction in Inappropriate Therapy and Mortality through ICD Programming
Moss, A. J., Schuger, C., Beck, C. A., Brown, M. W., Cannom, D. S., Daubert, J. P., Estes, N. A. M., Greenberg, H., Hall, W. J., Huang, D. T., et al. (2012) · New England Journal of Medicine · doi:10.1056/nejmoa1211107 · Cited by 1,378
An Entirely Subcutaneous Implantable Cardioverter–Defibrillator
Bardy, G. H., Smith, W. M., Hood, M. A., Crozier, I. G., Melton, I. C., Jordaens, L., Theuns, D., Park, R. E., Wright, D. J., Connelly, D. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0909545 · Cited by 780
Self-citationWathen, M. S., DeGroot, P. J., Sweeney, M. O., Stark, A. J., Otterness, M. F., Adkisson, W. O., Canby, R. C., Khalighi, K., Machado, C., Rubenstein, D. S., et al. (2004) · Circulation · doi:10.1161/01.cir.0000145610.64014.e4 · Cited by 775
Safety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator
Weiss, R., Knight, B. P., Gold, M. R., Leon, A. R., Herre, J. M., Hood, M., Rashtian, M., Kremers, M., Crozier, I., Lee, K. L., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.003042 · Cited by 557
Self-citationLambiase, P. D., Barr, C., Theuns, D. A. M. J., Knops, R., Neuzil, P., Johansen, J. B., Hood, M., Pedersen, S., Kääb, S., Murgatroyd, F., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu112 · Cited by 462
Self-citationvan Rees, J. B., de Bie, M. K., Thijssen, J., Borleffs, C. J. W., Schalij, M. J., & van Erven, L. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2011.06.007 · Cited by 305
Healey, J. S., Hohnloser, S. H., Glikson, M., Neuzner, J., Mabo, P., Vinolas, X., Kautzner, J., O'Hara, G., VanErven, L., Gadler, F., et al. (2015) · The Lancet · doi:10.1016/s0140-6736(14)61903-6 · Cited by 245
Self-citationThe Entirely Subcutaneous Implantable Cardioverter-Defibrillator
Olde Nordkamp, L. R. A., Dabiri Abkenari, L., Boersma, L. V. A., Maass, A. H., de Groot, J. R., van Oostrom, A. J. H. H. M., Theuns, D. A. M. J., Jordaens, L. J. L. M., Wilde, A. A. M., & Knops, R. E. (2012) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2012.06.053 · Cited by 223
Self-citationGOLD, M. R., THEUNS, D. A., KNIGHT, B. P., STURDIVANT, J. L., SANGHERA, R., ELLENBOGEN, K. A., WOOD, M. A., & BURKE, M. C. (2012) · Journal of Cardiovascular Electrophysiology · doi:10.1111/j.1540-8167.2011.02199.x · Cited by 211
Self-citationThe Dilemma of ICD Implant Testing
Swerdlow, C. D., Russo, A. M., & DeGroot, P. (2007) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2007.00730.x · Cited by 154
Efficacy and Temporal Stability of Reduced Safety Margins for Ventricular Defibrillation
Gold, M. R., Higgins, S. L., Klein, R. C., Gilliam, F. R., Kopelman, H. A., Hessen, S. E., PAYNE, J. P., Strickberger, S. A., Breiter, D. J., & Hahn, S. J. (2002) · Circulation · doi:10.1161/01.cir.0000015508.59749.f5 · Cited by 136
Self-citationPeterson, P. N., Varosy, P. D., Heidenreich, P. A., Wang, Y., Dewland, T. A., Curtis, J. P., Go, A. S., Greenlee, R. T., Magid, D. J., Normand, S. T., et al. (2013) · JAMA · doi:10.1001/jama.2013.4982 · Cited by 136
Electrical Storm in Patients with an Implanted Defibrillator: A Matter of Definition
Israel, C. W., & Barold, S. S. (2007) · Annals of Noninvasive Electrocardiology · doi:10.1111/j.1542-474x.2007.00187.x · Cited by 134
Kooiman, K. M., Knops, R. E., Nordkamp, L. R. A. O., Wilde, A. A. M., & de Groot, J. R. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.12.007 · Cited by 121
Self-citationPhysician Procedure Volume and Complications of Cardioverter-Defibrillator Implantation
Freeman, J. V., Wang, Y., Curtis, J. P., Heidenreich, P. A., & Hlatky, M. A. (2011) · Circulation · doi:10.1161/circulationaha.111.046995 · Cited by 104
Gold, M. R., Weiss, R., Theuns, D. A. M. J., Smith, W., León, A. R., Knight, B. P., Carter, N., Husby, M. P., & Burke, M. C. (2014) · Heart Rhythm · doi:10.1016/j.hrthm.2014.04.012 · Cited by 99
Self-citationPoole, J. E., & Gold, M. R. (2013) · Circulation Arrhythmia and Electrophysiology · doi:10.1161/circep.113.000481 · Cited by 54
Self-citationClinical Impact, Safety, and Efficacy of Single‐ versus Dual‐Coil ICD Leads in MADIT‐CRT
Kutyifa, V., Ruwald, A., Aktaş, M. K., Jøns, C., McNitt, S. A., Polonsky, B., Gellér, L., Merkely, B. P., Moss, A. J., Zaręba, W., et al. (2013) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12219 · Cited by 44
Cha, Y., Hayes, D. L., Asirvatham, S. J., Powell, B. D., Cesario, D. A., Cao, M. K., Gilliam, F. R., Jones, P. W., Jiang, S., & Saxon, L. A. (2013) · Heart Rhythm · doi:10.1016/j.hrthm.2013.01.019 · Cited by 18
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
2016 ESC Guidelines for the diagnosis and treatment of acute and chronic heart failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Heart Journal · doi:10.1093/eurheartj/ehw128 · Cited by 11,429
2016 ESC Guidelines for the Diagnosis and Treatment of Acute and Chronic Heart Failure
Ponikowski, P., Voors, A. A., Anker, S. D., Bueno, H., Cleland, J. G. F., Coats, A. J. S., Falk, V., González-Juanatey, J. R., Harjola, V.-P., Jankowska, E. A., et al. (2016) · European Journal of Heart Failure · doi:10.1002/ejhf.592 · Cited by 5,866
Priori, S. G., Blomström-Lundqvist, C., Mazzanti, A., Blom, N., Borggrefe, M., Camm, J., Elliott, P. M., Fitzsimons, D., Hatala, R., Hindricks, G., et al. (2015) · European Heart Journal · doi:10.1093/eurheartj/ehv316 · Cited by 3,893
Self-citation
Metadata
- Authors
- Burke, M. C., Gold, M. R., Knight, B. P., Barr, C. S., Theuns, D. A. M. J., Boersma, L. V. A., Knops, R. E., Weiss, R., Leon, A. R., Herre, J. M., Husby, M., Stein, K. M., & Lambiase, P. D.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2015-04
- Volume
- 65
- Issue
- 16
- Pages
- 1605-1615
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W247326599
- Cited by
- 505
- References
- 23
- FWCI
- 59.56
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.