The DOI matches its Crossref record; 27 of the 27 references it cites were found in a registry or an index.
Implant and Midterm Outcomes of the Subcutaneous Implantable Cardioverter-Defibrillator Registry
Open accessAbstract
BACKGROUND: The subcutaneous implantable cardioverter-defibrillator (S-ICD) was developed to defibrillate ventricular arrhythmias, avoiding drawbacks of transvenous leads. The global EFFORTLESS S-ICD (Evaluation oF FactORs ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD) registry is collecting outcomes in 985 patients during a 5-year follow-up. OBJECTIVES: The primary goal of the EFFORTLESS registry is to determine the safety of the S-ICD by evaluating complications and inappropriate shock rate. METHODS: This is the first report on the full patient cohort and study endpoints with follow-up ≥1 year. The predefined endpoints are 30- and 360-day complications, and shocks for atrial fibrillation or supraventricular tachycardia. RESULTS: Patients were followed for 3.1 ± 1.5 years and 82 completed the study protocol 5-year visit. Average age was 48 years, 28% were women, ejection fraction was 43 ± 18%, and 65% had a primary prevention indication. The S-ICD system and procedure complication rate was 4.1% at 30 days and 8.4% at 360 days. The 1-year complication rate trended toward improvement from the first to last quartile of enrollment (11.3% [quartile 1]) to 7.8% [quartile 2], 6.6% [quartile 3], and 7.4% [quartile 4]; quartile 1 vs. quartiles 2 to 4; p = 0.06). Few device extractions occurred due to need for antitachycardia (n = 5), or biventricular (n = 4) or bradycardia pacing (n = 1). Inappropriate shocks occurred in 8.1% at 1 year and 11.7% after 3.1 years. At implant, 99.5% of patients had a successful conversion of induced ventricular tachycardia or ventricular fibrillation. The 1- and 5-year rates of appropriate shock were 5.8% and 13.5%, respectively. Conversion success for discrete spontaneous episodes was 97.4% overall. CONCLUSIONS: This registry demonstrates that the S-ICD fulfills predefined endpoints for safety and efficacy. Midterm performance rates on complications, inappropriate shocks, and conversion efficacy were comparable to rates observed in transvenous implantable cardioverter-defibrillator studies. (Evaluation oF Factors ImpacTing CLinical Outcome and Cost EffectiveneSS of the S-ICD [The EFFORTLESS S-ICD Registry]; NCT01085435).
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Moss, A. J., Zareba, W., Hall, W. J., Klein, H., Wilber, D. J., Cannom, D. S., Daubert, J. P., Higgins, S. L., Brown, M. W., & Andrews, M. L. (2002) · New England Journal of Medicine · doi:10.1056/nejmoa013474 · Cited by 6,902
Oss, J. M., Areba, W. O. Z., Ackson, W. J., Lein, H. E. K., Ilber, D. A. J. W., Annom, D. A. S. C., Ames, J. M., Aubert, P., Iggins, S. T. L. H., Rown, M. A. W. B., et al. (2002) · Cited by 2,027
Prognostic Importance of Defibrillator Shocks in Patients with Heart Failure
Poole, J. E., Johnson, G. W., Hellkamp, A. S., Anderson, J., Callans, D. J., Raitt, M. H., Reddy, R. K., Marchlinski, F. E., Yee, R., Guarnieri, T., et al. (2008) · New England Journal of Medicine · doi:10.1056/nejmoa071098 · Cited by 1,462
Inappropriate Implantable Cardioverter-Defibrillator Shocks in MADIT II
Daubert, J. P., Zareba, W., Cannom, D. S., McNitt, S., Rosero, S. Z., Wang, P., Schuger, C., Steinberg, J. S., Higgins, S. L., Wilber, D. J., et al. (2008) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2007.09.073 · Cited by 813
An Entirely Subcutaneous Implantable Cardioverter–Defibrillator
Bardy, G. H., Smith, W. M., Hood, M. A., Crozier, I. G., Melton, I. C., Jordaens, L., Theuns, D., Park, R. E., Wright, D. J., Connelly, D. T., et al. (2010) · New England Journal of Medicine · doi:10.1056/nejmoa0909545 · Cited by 780
Self-citationSafety and Efficacy of a Totally Subcutaneous Implantable-Cardioverter Defibrillator
Weiss, R., Knight, B. P., Gold, M. R., Leon, A. R., Herre, J. M., Hood, M., Rashtian, M., Kremers, M., Crozier, I., Lee, K. L., et al. (2013) · Circulation · doi:10.1161/circulationaha.113.003042 · Cited by 557
Self-citationSaxon, L. A., Hayes, D. L., Gilliam, F. R., Heidenreich, P. A., Day, J., Seth, M., Meyer, T. E., Jones, P. W., & Boehmer, J. P. (2010) · Circulation · doi:10.1161/circulationaha.110.960633 · Cited by 515
Self-citationSafety and Efficacy of the Totally Subcutaneous Implantable Defibrillator
Burke, M. C., Gold, M. R., Knight, B. P., Barr, C. S., Theuns, D. A. M. J., Boersma, L. V. A., Knops, R. E., Weiss, R., Leon, A. R., Herre, J. M., et al. (2015) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2015.02.047 · Cited by 505
Self-citationLambiase, P. D., Barr, C., Theuns, D. A. M. J., Knops, R., Neuzil, P., Johansen, J. B., Hood, M., Pedersen, S., Kääb, S., Murgatroyd, F., et al. (2014) · European Heart Journal · doi:10.1093/eurheartj/ehu112 · Cited by 462
Self-citationInappropriate Implantable Cardioverter-Defibrillator Shocks
van Rees, J. B., Borleffs, C. J. W., de Bie, M. K., Stijnen, T., van Erven, L., Bax, J. J., & Schalij, M. J. (2011) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.06.059 · Cited by 451
Olde Nordkamp, L. R. A., Postema, P. G., Knops, R. E., van Dijk, N., Limpens, J., Wilde, A. A. M., & de Groot, J. R. (2016) · Heart Rhythm · doi:10.1016/j.hrthm.2015.09.010 · Cited by 267
Self-citationGoldenberg, I., Moss, A. J., McNitt, S., Zareba, W., Andrews, M. L., Hall, W. J., Greenberg, H., & Case, R. B. (2006) · The American Journal of Cardiology · doi:10.1016/j.amjcard.2006.03.025 · Cited by 209
Long-Term Clinical Outcomes of Subcutaneous Versus Transvenous Implantable Defibrillator Therapy
Brouwer, T. F., Yilmaz, D., Lindeboom, R., Buiten, M. S., Olde Nordkamp, L. R. A., Schalij, M. J., Wilde, A. A., van Erven, L., & Knops, R. E. (2016) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2016.08.044 · Cited by 179
Self-citationEzzat, V. A., Lee, V., Ahsan, S., Chow, A. W., Segal, O., Rowland, E., Lowe, M. D., & Lambiase, P. D. (2015) · Open Heart · doi:10.1136/openhrt-2014-000198 · Cited by 176
Self-citationOlde Nordkamp, L. R. A., Knops, R. E., Bardy, G. H., Blaauw, Y., Boersma, L. V. A., Bos, J. S., Delnoy, P. P. H. M., van Dessel, P. F. H. M., Driessen, A. H. G., de Groot, J. R., et al. (2012) · American Heart Journal · doi:10.1016/j.ahj.2012.02.012 · Cited by 168
Self-citationKöbe, J., Reinke, F., Meyer, C. G., Shin, D., Martens, E., Kääb, S., Löher, A., Amler, S., Lichtenberg, A., Winter, J., et al. (2012) · Heart Rhythm · doi:10.1016/j.hrthm.2012.09.126 · Cited by 146
Self-citationA New Algorithm to Reduce Inappropriate Therapy in the S‐ICD System
Brisben, A., Burke, M. C., Knight, B. P., Hahn, S. J., Herrmann, K. L., Allavatam, V., Mahajan, D., Sanghera, R., & Gold, M. R. (2015) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12612 · Cited by 123
Do atrial tachyarrhythmias beget ventricular tachyarrhythmias in defibrillator recipients?
Steín, K. M., Euler, D. E., Mehra, R., Seidl, K., Slotwiner, D. J., Mittal, S., Markowitz, S. M., & Lerman, B. B. (2002) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(02)01957-5 · Cited by 122
The learning curve associated with the introduction of the subcutaneous implantable defibrillator
Knops, R. E., Brouwer, T. F., Barr, C. S., Theuns, D. A. M. J., Boersma, L. V. A., Weiss, R., Neužil, P., SCHOLTEN, M. F., Lambiase, P. D., León, A. R., et al. (2015) · EP Europace · doi:10.1093/europace/euv299 · Cited by 114
Self-citationPredictors of VT/VF-occurrence in ICD patients: results from the PROFIT-Study
Klein, G. G., Lissel, C., Fuchs, A.-C., Gardiwal, A., Oswald, H., deSousa, M., Pichlmaier, A. M., Lichtinghagen, R., Geerlings, H., Lippolt, P., et al. (2006) · EP Europace · doi:10.1093/europace/eul082 · Cited by 77
Renal insufficiency predicts the time to first appropriate defibrillator shock
Hreybe, H., Ezzeddine, R., Bedi, M., Barrington, W., Bazaz, R. R., Ganz, L. I., Jain, S. K., Ngwu, O., London, B., & Saba, S. (2006) · American Heart Journal · doi:10.1016/j.ahj.2005.06.042 · Cited by 60
Pedersen, S. S., Lambiase, P. D., Boersma, L. V. A., MURGATROYD, F. D., Johansen, J. B., Reeve, H. L., Stuart, G., Adragão, P., & Theuns, D. A. M. J. (2012) · Pacing and Clinical Electrophysiology · doi:10.1111/j.1540-8159.2012.03337.x · Cited by 44
Self-citationClémenty, N., Pierre, B., Lallemand, B., Marie, O., Lemoine, E., Cosnay, P., Fauchier, L., & Babuty, D. (2012) · EP Europace · doi:10.1093/europace/eus028 · Cited by 41
Sedláček, K., Ruwald, A., Kutyifa, V., McNitt, S. A., Thomsen, P. E. B., Klein, H., Stockburger, M. A., Wichterle, D., Merkely, B. P., de la Concha, J. F., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12605 · Cited by 33
Sanghera, R., Sanders, R., Husby, M. P., & Bentsen, J. G. (2014) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.12550 · Cited by 25
Self-citationEisen, A., Suleiman, M. A., Strasberg, B., Sela, R., Rosenheck, S., FREEDBERG, N. A., GEIST, M., Ben‐Zvi, S., Goldenberg, I., Glikson, M., et al. (2014) · Journal of Cardiovascular Electrophysiology · doi:10.1111/jce.12442 · Cited by 16
Biton, Y., Huang, D. T.-C., Goldenberg, I., Rosero, S. Z., Moss, A. J., Kutyifa, V., McNitt, S. A., Strasberg, B., Zaręba, W., & Barsheshet, A. (2015) · Heart Rhythm · doi:10.1016/j.hrthm.2015.12.032 · Cited by 11
Cited by
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab670 · Cited by 19,442
2021 ESC guidelines for the diagnosis and treatment of acute and chronic heart failure
McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., Chioncel, O., et al. (2021) · European Heart Journal · doi:10.1093/eurheartj/ehab368 · Cited by 13,344
Authors/Task Force Members:, McDonagh, T. A., Metra, M., Adamo, M., Gardner, R. S., Baumbach, A., Böhm, M., Burri, H., Butler, J., Čelutkienė, J., et al. (2022) · European Journal of Heart Failure · doi:10.1002/ejhf.2333 · Cited by 2,171
Rangaswami, J., Bhalla, V., Blair, J. E. A., Chang, T. I., Costa, S., Lentine, K. L., Lerma, E. V., Mezue, K., Molitch, M., Mullens, W., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000664 · Cited by 1,409
Arrhythmogenic Right Ventricular Cardiomyopathy
Corrado, D., Link, M. S., & Calkins, H. (2017) · New England Journal of Medicine · doi:10.1056/nejmra1509267 · Cited by 736
Metadata
- Authors
- Boersma, L., Barr, C., Knops, R., Theuns, D., Eckardt, L., Neuzil, P., Scholten, M., Hood, M., Kuschyk, J., Jones, P., Duffy, E., Husby, M., Stein, K., & Lambiase, P. D.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2017-08
- Volume
- 70
- Issue
- 7
- Pages
- 830-841
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W2745135147
- Cited by
- 331
- References
- 27
- FWCI
- 27.18
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.