The DOI matches its Crossref record; 58 of the 58 references it cites were found in a registry or an index.
Coronary In-Stent Restenosis
Open accessAbstract
The introduction and subsequent iterations of drug-eluting stent technologies have substantially improved the efficacy and safety of percutaneous coronary interventions. However, the incidence of in-stent restenosis (ISR) and the resultant need for repeated revascularization still occur at a rate of 1%-2% per year. Given that millions of drug-eluting stents are implanted each year around the globe, ISR can be considered as a pathologic entity of public health significance. The mechanisms of ISR are multifactorial. Since the first description of the angiographic patterns of ISR, the advent of intracoronary imaging has further elucidated the mechanisms and patterns of ISR. The armamentarium and treatment strategies of ISR have also evolved over time. Currently, an individualized approach using intracoronary imaging to characterize the underlying substrate of ISR is recommended. In this paper, we comprehensively reviewed the incidence, mechanisms, and imaging characterization of ISR and propose a contemporary treatment algorithm.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
2018 ESC/EACTS guidelines on myocardial revascularization
Neumann, F.-J., Sousa-Uva, M., Ahlsson, A., Alfonso, F., Banning, A. P., Benedetto, U., Byrne, R. A., Collet, J.-P., Falk, V., Head, S. J., et al. (2019) · European Heart Journal · doi:10.1093/eurheartj/ehy394 · Cited by 7,167
Clinical End Points in Coronary Stent Trials: A Case for Standardized Definitions
Cutlip, D. E., Windecker, S., Mehran, R., Boam, A., Cohen, D. J., van Es, G.-A., Gabriel Steg, P., Morel, M.-A., Mauri, L., Vranckx, P., et al. (2007) · Circulation · doi:10.1161/circulationaha.106.685313 · Cited by 5,497
Self-citationPathology of Drug-Eluting Stents in Humans
Joner, M., Finn, A. V., Farb, A., Mont, E. K., Kolodgie, F. D., Ladich, E., Kutys, R., Skorija, K., Gold, H. K., & Virmani, R. (2006) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2006.03.042 · Cited by 2,744
2021 ACC/AHA/SCAI Guideline for Coronary Artery Revascularization
Lawton, J. S., Tamis-Holland, J. E., Bangalore, S., Bates, E. R., Beckie, T. M., Bischoff, J. M., Bittl, J. A., Cohen, M. G., DiMaio, J. M., Don, C. W., et al. (2022) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2021.09.006 · Cited by 1,558
Self-citationAngiographic Patterns of In-Stent Restenosis: Classification and Implications for Long-Term Outcome
Mehran, R., Dangas, G., Abizaid, A. S., Mintz, G. S., Lansky, A. J., Satler, L. F., Pichard, A. D., Kent, K. M., Stone, G. W., & Leon, M. B. (1999) · Circulation · doi:10.1161/01.cir.100.18.1872 · Cited by 1,258
Self-citationPatterns and Mechanisms of In-Stent Restenosis: A Serial Intravascular Ultrasound Study
Hoffmann, R., Mintz, G. S., Dussaillant, G. R., Popma, J. J., Pichard, A. D., Satler, L. F., Kent, K. M., Griffin, J., & Leon, M. B. (1996) · Circulation · doi:10.1161/01.cir.94.6.1247 · Cited by 1,247
Kastrati, A., Mehilli, J., Dirschinger, J., Dotzer, F., Schühlen, H., Neumann, F.-J., Fleckenstein, M., Pfafferott, C., Seyfarth, M., & Schömig, A. (2001) · Circulation · doi:10.1161/01.cir.103.23.2816 · Cited by 938
Drug-Eluting Stent and Coronary Thrombosis: Biological Mechanisms and Clinical Implications
Lüscher, T. F., Steffel, J., Eberli, F. R., Joner, M., Nakazawa, G., Tanner, F. C., & Virmani, R. (2007) · Circulation · doi:10.1161/circulationaha.106.675934 · Cited by 906
Treatment of Coronary In-Stent Restenosis with a Paclitaxel-Coated Balloon Catheter
Scheller, B., Hehrlein, C., Bocksch, W., Rutsch, W., Haghi, D., Dietz, U., Böhm, M., & Speck, U. (2006) · New England Journal of Medicine · doi:10.1056/nejmoa061254 · Cited by 816
In-Stent Restenosis in the Drug-Eluting Stent Era
Dangas, G. D., Claessen, B. E., Caixeta, A., Sanidas, E. A., Mintz, G. S., & Mehran, R. (2010) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2010.07.028 · Cited by 803
Self-citation
Metadata
- Authors
- Giustino, G., Colombo, A., Camaj, A., Yasumura, K., Mehran, R., Stone, G. W., Kini, A., & Sharma, S. K.
- Venue
- Journal of the American College of Cardiology
- Publisher
- Elsevier BV
- Published
- 2022-07
- Volume
- 80
- Issue
- 4
- Pages
- 348-372
- ISSN
- 0735-1097 (ISSN-L)
- OpenAlex
- W4285806621
- Cited by
- 413
- References
- 58
- FWCI
- 64.43
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Coronary In-Stent Restenosis. https://app.cochat.ai/papers/10.1016/j.jacc.2022.05.017
- The paper
- Giustino, G., Colombo, A., Camaj, A., Yasumura, K., Mehran, R., Stone, G. W., Kini, A., & Sharma, S. K. (2022). Coronary In-Stent Restenosis. Journal of the American College of Cardiology. https://doi.org/10.1016/j.jacc.2022.05.017
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.