Cited by 47Cardiac Arrhythmias and TreatmentsCardiac electrophysiology and arrhythmiasCardiac pacing and defibrillation studies

Ablation of Inappropriate Sinus Tachycardia

Open access
Rodríguez-Mañero, Moisés, Kreidieh, Bahij, Al Rifai, Mahmoud, Ibarra-Cortez, Sergio, Schurmann, Paul, Álvarez, Paulino A., Fernández-López, Xesús Alberte, García-Seara, Javier +3 more·2017·JACC: Clinical Electrophysiology

Abstract

OBJECTIVES: The goal of this study was to describe short- and long-term outcomes in all patients referred for inappropriate sinus tachycardia ablation, along with the potential complications of the intervention. BACKGROUND: Sinus node (SN) ablation/modification has been proposed for patients refractory to pharmacological therapy. However, available data derive from limited series. METHODS: The electronic databases MEDLINE, Embase, CINAHL, Cochrane, and Scopus were systematically searched (January 1, 1995-December 31, 2015). Studies were screened according to predefined inclusion and exclusion criteria. RESULTS: A total of 153 patients were included. Their mean age was 35.18 ± 10.02 years, and 139 (90.8%) were female. All patients had failed to respond to maximum tolerated doses of pharmacological therapy (3.5 ± 2.4 drugs). Mean baseline heart rates averaged 101.3 ± 16.4 beats/min according to electrocardiography and 104.5 ± 13.5 beats/min according to 24-h Holter monitoring. Two electrophysiological strategies were used, SN ablation and SN modification, with the latter being used more. Procedural acute success (using variably defined pre-determined endpoints) was 88.9%. Consistently, all groups reported high-output pacing from the ablation catheter to confirm absence of phrenic nerve stimulation before radiofrequency delivery. Need of pericardial access varied between 0% and 76.9%. Thirteen patients (8.5%) experienced severe procedural complications, and 15 patients (9.8%) required implantation of a pacemaker. At a mean follow-up interval of 28.1 ± 12.6 months, 86.4% of patients demonstrated successful outcomes. The symptomatic recurrence rate was 19.6%, and 29.8% of patients continued to receive antiarrhythmic drug therapy after procedural intervention. CONCLUSIONS: Inappropriate sinus tachycardia ablation/modification achieves acute success in the vast majority of patients. Complications are fairly common and diverse. However, symptomatic relief decreases substantially over longer follow-up periods, with a corresponding high recurrence rate.

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacep.2016.09.014

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

  • 9.8% of patients in the meta-analysis required pacemaker implantation.

    “The acute success was 88.9% but 8.5% experienced severe procedural complications (diaphragmatic paralysis, AV fistula, and retroperitoneal bleed) and 9.8% required pacemaker implantation.”

    From Inappropriate sinus tachycardia (2019) · cites this paper as [89]

  • A meta-analysis of ablation studies (9 studies, 153 patients, mean age 35, 91% female) has been performed.

    “A meta-analysis of ablation studies (9 studies, 153 patients, mean age = 35, 91% female) has been performed. 89”

    From Inappropriate sinus tachycardia (2019) · cites this paper as [89]

  • 30% of patients in the meta-analysis required continued drug therapy.

    “Symptom recurrence rate was 19.6% and 30% required continued drug therapy.”

    From Inappropriate sinus tachycardia (2019) · cites this paper as [89]

  • All patients in the meta-analysis failed to respond to maximal pharmacological therapy.

    “All patients failed to respond to a maximal pharmacological therapy.”

    From Inappropriate sinus tachycardia (2019) · cites this paper as [89]

  • Superior vena cava syndrome was apparent in two patients in the meta-analysis.

    “Superior vena cava syndrome was apparent in two and some underwent ablation of the AV junction.”

    From Inappropriate sinus tachycardia (2019) · cites this paper as [89]

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Cites

Flagged first, then by citations

Cited by

Sorted by citations

Authors
Rodríguez-Mañero, M., Kreidieh, B., Al Rifai, M., Ibarra-Cortez, S., Schurmann, P., Álvarez, P. A., Fernández-López, X. A., García-Seara, J., Martínez-Sande, L., González-Juanatey, J. R., & Valderrábano, M.
Affiliations
Houston Methodist (US)
Corresponding author
Valderrábano, Miguel
Venue
JACC: Clinical Electrophysiology
Publisher
Elsevier BV
Published
2017-03
Volume
3
Issue
3
Pages
253-265
ISSN
2405-500X (ISSN-L)
OpenAlex
W2561228512
Cited by
47
References
25
Citations by year
2026: 1 · 2025: 3 · 2024: 6 · 2023: 2 · 2022: 6 · 2021: 14 · 2020: 4 · 2019: 6 · 2018: 2 · 2017: 1 · 2012: 1
FWCI
2.48
Type
journal article
Language
en
Open access
Locations
  • JACC. Clinical electrophysiology (publishedVersion, other-oa)
  • PubMed (publishedVersion)
  • Europe PMC (PubMed Central) (acceptedVersion)
  • PubMed Central (acceptedVersion)
Funders
  • American College of Cardiology Foundation
  • National Heart, Lung, and Blood Institute (R01HL115003)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac Arrhythmias and Treatments
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac electrophysiology and arrhythmias
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › Cardiac pacing and defibrillation studies
Keywords
inappropriate sinus tachycardia, radiofrequency catheter ablation, procedural complications, phrenic nerve stimulation, pacemaker implantation, antiarrhythmic therapy, recurrence, long-term outcomes
MeSH terms
Adult, Anti-Arrhythmia Agents, Electrocardiography, Female, Follow-Up Studies, Humans, Male, Middle Aged, Pacemaker, Artificial, Pericardium, Phrenic Nerve, Recurrence, Sinoatrial Node, Tachycardia, Sinus, Electrocardiography, Ambulatory, Treatment Outcome, Catheter Ablation, Body Surface Potential Mapping, Electrophysiologic Techniques, Cardiac

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review