CoChat

Machine Learning for Automation of Radiology Protocols for Quality and Efficiency Improvement

Kalra, Angad, Chakraborty, Amit, Fine, Benjamin, Reicher, Joshua · 2020 · Journal of the American College of Radiology
Cited by 93

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

PURPOSE The aim of this study was to enhance multispecialty CT and MRI protocol assignment quality and efficiency through development, testing, and proposed workflow design of a natural language processing (NLP)-based machine learning classifier. METHODS NLP-based machine learning classification models were developed using order entry input data and radiologist-assigned protocols from more than 18,000 unique CT and MRI examinations obtained during routine clinical use. k-Nearest neighbor, random forest, and deep neural network classification models were evaluated at baseline and after applying class frequency and confidence thresholding techniques. To simulate performance in real-world deployment, the model was evaluated in two operating modes in combination: automation (automated assignment of the top result) and clinical decision support (CDS; top-three protocol suggestion for clinical review). Finally, model-radiologist discordance was subjectively reviewed to guide explainability and safe use. RESULTS Baseline protocol assignment performance achieved weighted precision of 0.757 to 0.824. Simulating real-world deployment using combined thresholding techniques, the optimized deep neural network model assigned 69% of protocols in automation mode with 95% accuracy. In the remaining 31% of cases, the model achieved 92% accuracy in CDS mode. Analysis of discordance with subspecialty radiologist labels revealed both more and less appropriate model predictions. CONCLUSIONS A multiclass NLP-based classification algorithm was designed to drive local operations improvement in CT and MR radiology protocol assignment at subspecialist quality. The results demonstrate a simulated workflow deployment enabling automated assignment of protocols in nearly 70% of cases with very few errors combined with top-three CDS for remaining cases supporting a high-quality, efficient radiology workflow.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jacr.2020.03.012

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

Metadata

Authors
Kalra, A., Chakraborty, A., Fine, B., & Reicher, J.
Venue
Journal of the American College of Radiology
Publisher
Elsevier BV
Published
2020-09
Volume
17
Issue
9
Pages
1149-1158
ISSN
1546-1440 (ISSN-L)
OpenAlex
W3015264156
Cited by
93
References
4
FWCI
2.50
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.