The DOI matches its Crossref record; 28 of the 28 references it cites were found in a registry or an index.
Perfusion Assessment in Laparoscopic Left-Sided/Anterior Resection (PILLAR II): A Multi-Institutional Study
Open accessAbstract
BACKGROUND: Our primary objective was to demonstrate the utility and feasibility of the intraoperative assessment of colon and rectal perfusion using fluorescence angiography (FA) during left-sided colectomy and anterior resection. Anastomotic leak (AL) after colorectal resection increases morbidity, mortality, and, in cancer cases, recurrence rates. Inadequate perfusion may contribute to AL. The PINPOINT Endoscopic Fluorescence Imaging System allows for intraoperative assessment of anastomotic perfusion. STUDY DESIGN: This is a prospective, multicenter, open-label, clinical trial that assessed the feasibility and utility of FA for intraoperative perfusion assessment during left-sided colectomy and anterior resection at 11 centers in the United States. RESULTS: A total of 147 patients were enrolled, of whom 139 were eligible for analysis. Diverticulitis (44%), rectal cancer (25%), and colon cancer (21%) were the most prevalent indications for surgery. The mean level of anastomosis was 10 ± 4 cm from the anal verge. Splenic-flexure mobilization was performed in 81% and high ligation of the inferior mesenteric artery in 61.9% of patients. There was a 99% success rate for FA, and FA changed surgical plans in 11 (8%) patients, with the majority of changes occurring at the time of transection of the proximal margin (7%). Overall morbidity rates were 17%. The anastomotic leak rate was 1.4% (n = 2). There were no anastomotic leaks in the 11 patients who had a change in surgical plan based on intraoperative perfusion assessment with FA. CONCLUSIONS: PINPOINT is a safe and feasible tool for intraoperative assessment of tissue perfusion during colorectal resection. There were no anastomotic leaks in patients in whom the anastomosis was revised based on inadequate perfusion with FA.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Pharmacological interventions for somatoform disorders in adults
Kleinstäuber, M., Witthöft, M., Steffanowski, A., van Marwijk, H., Hiller, W., & Lambert, M. J. (2014) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd010628.pub2 · Cited by 11,335
Guillou, P. J., Quirke, P., Thorpe, H., Walker, J., Jayne, D. G., Smith, A. M., Heath, R. M., & Brown, J. M. (2005) · The Lancet · doi:10.1016/s0140-6736(05)66545-2 · Cited by 3,064
A Review of Indocyanine Green Fluorescent Imaging in Surgery
Alander, J. T., Kaartinen, I., Laakso, A., Pätilä, T., Spillmann, T., Tuchin, V. V., Venermo, M., & Välisuo, P. (2012) · International Journal of Biomedical Imaging · doi:10.1155/2012/940585 · Cited by 1,352
Matthiessen, P., Hallböök, O., Rutegård, J., Simert, G., & Sjödahl, R. (2007) · Annals of Surgery · doi:10.1097/sla.0b013e3180603024 · Cited by 1,123
Risk factors for anastomotic leakage after resection of rectal cancer
Rullier, E., Laurent, C., Garrelon, J. L., Michel, P., Saric, J., & Parneix, M. (1998) · Journal of British Surgery · doi:10.1046/j.1365-2168.1998.00615.x · Cited by 895
Anastomotic Leaks After Intestinal Anastomosis: It??s Later Than You Think
Hyman, N., Manchester, T. L., Osler, T., Burns, B., & Cataldo, P. A. (2007) · Annals of Surgery · doi:10.1097/01.sla.0000225083.27182.85 · Cited by 652
Colonic Anastomotic Leak: Risk Factors, Diagnosis, and Treatment
Kingham, P. T., & Pachter, L. H. (2009) · Journal of the American College of Surgeons · doi:10.1016/j.jamcollsurg.2008.10.015 · Cited by 519
McArdle, C. S., McMillan, D. C., & Hole, D. J. (2005) · British Journal of Surgery · doi:10.1002/bjs.5054 · Cited by 480
Law, W. L., & Chu, K. W. (2004) · Annals of Surgery · doi:10.1097/01.sla.0000133185.23514.32 · Cited by 475
Surgeons lack predictive accuracy for anastomotic leakage in gastrointestinal surgery
Karliczek, A., Harlaar, N. J., Zeebregts, C. J., Wiggers, T., Baas, P. C., & van Dam, G. M. (2009) · International Journal of Colorectal Disease · doi:10.1007/s00384-009-0658-6 · Cited by 464
Risk Factors for Anastomotic Leakage After Anterior Resection for Rectal Cancer
Kang, C. Y., Halabi, W. J., Chaudhry, O. O., Nguyen, V., Pigazzi, A., Carmichael, J. C., Mills, S., & Stamos, M. J. (2013) · JAMA Surgery · doi:10.1001/2013.jamasurg.2 · Cited by 422
Self-citationAltered microperfusion at the rectal stump is predictive for rectal anastomotic leak
Vignali, A., Gianotti, L., Braga, M., Radaelli, G., Malvezzi, L., & Carlo, V. D. (2000) · Diseases of the Colon & Rectum · doi:10.1007/bf02237248 · Cited by 355
Jafari, M. D., Lee, K. H., Halabi, W. J., Mills, S. D., Carmichael, J. C., Stamos, M. J., & Pigazzi, A. (2013) · Surgical Endoscopy · doi:10.1007/s00464-013-2832-8 · Cited by 337
Self-citationKudszus, S., Roesel, C., Schachtrupp, A., & Höer, J. J. (2010) · Langenbeck's Archives of Surgery · doi:10.1007/s00423-010-0699-x · Cited by 334
Enker, W. E., Merchant, N., Cohen, A. M., Lanouette, N. M., Swallow, C., Guillem, J., Paty, P., Minsky, B., Weyrauch, K., & Quan, S. H. Q. (1999) · Annals of Surgery · doi:10.1097/00000658-199910000-00010 · Cited by 299
Dehni, N., Schlegel, R. D., Cunningham, C., Guiguet, M., Tiret, E., & Parc, R. (1998) · Journal of British Surgery · doi:10.1046/j.1365-2168.1998.00790.x · Cited by 264
Covering ileo- or colostomy in anterior resection for rectal carcinoma
Montedori, A., Cirocchi, R., Farinella, E., Sciannameo, F., & Abraha, I. (2010) · Cochrane Database of Systematic Reviews · doi:10.1002/14651858.cd006878.pub2 · Cited by 246
Sauer, R., Fietkau, R., Wittekind, C., Rödel, C., Martus, P., Hohenberger, W., Tschmelitsch, J., Sabitzer, H., Karstens, J. ‐., Becker, H., et al. (2003) · Colorectal Disease · doi:10.1046/j.1463-1318.2003.00509.x · Cited by 219
Tissue oxygen tension as a predictor of colonic anastomotic healing
Sheridan, W. G., Lowndes, R. H., & Young, H. L. (1987) · Diseases of the Colon & Rectum · doi:10.1007/bf02555426 · Cited by 204
Holm, C., Tegeler, J., Mayr, M. F., Becker, A., Pfeiffer, U. J., & Mühlbauer, W. D. (2002) · Microsurgery · doi:10.1002/micr.10052 · Cited by 156
Shimada, Y., Okumura, T., Nagata, T., Sawada, S., Matsui, K., Hori, R., Yoshioka, I., Yoshida, T., Osada, R., & Tsukada, K. (2011) · Esophagus · doi:10.1007/s10388-011-0291-7 · Cited by 141
Boyle, H. N., Manifold, D. K., Jordan, H. M., et al. (2000) · Journal of the American College of Surgeons · doi:10.1016/s1072-7515(00)00709-2 · Cited by 114
Intraoperative assessment of colorectal anastomotic integrity: a systematic review
Nachiappan, S., Askari, A., Currie, A., Kennedy, R. H., & Faiz, O. D. (2014) · Surgical Endoscopy · doi:10.1007/s00464-014-3520-z · Cited by 109
Blood Flow in Colonic Anastomoses
Chung, R. S. K. (1987) · Annals of Surgery · doi:10.1097/00000658-198709000-00011 · Cited by 99
Near-Infrared Fluorescence Imaging in Patients Undergoing Pancreaticoduodenectomy
Hutteman, M., van der Vorst, J. R., Mieog, J. S. D., Bonsing, B. A., Hartgrink, H. H., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. �., & Vahrmeijer, A. L. (2011) · European Surgical Research · doi:10.1159/000329411 · Cited by 98
Near‐infrared laparoscopy for real‐time intra‐operative arterial and lymphatic perfusion imaging
Cahill, R. A., Ris, F., & Mortensen, N. J. M. C. (2011) · Colorectal Disease · doi:10.1111/j.1463-1318.2011.02772.x · Cited by 84
Rodríguez-Hernández, A., & Lawton, M. T. (2011) · Operative Neurosurgery · doi:10.1227/neu.0b013e31823158f3 · Cited by 49
Cahill, R. A., & Mortensen, N. J. M. C. (2010) · PubMed · Cited by 28
Cited by
Near‐Infrared‐II Molecular Dyes for Cancer Imaging and Surgery
Zhu, S., Tian, R., Antaris, A. L., Chen, X., & Dai, H. (2019) · Advanced Materials · doi:10.1002/adma.201900321 · Cited by 972
2017 WSES guidelines on colon and rectal cancer emergencies: obstruction and perforation
Pisano, M., Zorcolo, L., Merli, C., Cimbanassi, S., Poiasina, E., Ceresoli, M., Agresta, F., Allievi, N., Bellanova, G., Coccolini, F., et al. (2018) · World Journal of Emergency Surgery · doi:10.1186/s13017-018-0192-3 · Cited by 396
Self-citationPenna, M., Hompes, R., Arnold, S., Wynn, G., Austin, R., Warusavitarne, J., Moran, B., Hanna, G. B., Mortensen, N. J., & Tekkis, P. P. (2019) · Annals of Surgery · doi:10.1097/sla.0000000000002653 · Cited by 358
Predictive factors for anastomotic leakage after laparoscopic colorectal surgery
Sciuto, A., Merola, G., Palma, G. D. D., Sodo, M., Pirozzi, F., Bracale, U. M., & Bracale, U. (2018) · World Journal of Gastroenterology · doi:10.3748/wjg.v24.i21.2247 · Cited by 353
Blanco-Colino, R., & Espin-Basany, E. (2018) · Techniques in Coloproctology · doi:10.1007/s10151-017-1731-8 · Cited by 344
Metadata
- Authors
- Jafari, M. D., Wexner, S. D., Martz, J. E., McLemore, E. C., Margolin, D. A., Sherwinter, D. A., Lee, S. W., Senagore, A. J., Phelan, M. J., & Stamos, M. J.
- Venue
- Journal of the American College of Surgeons
- Published
- 2015-01
- Volume
- 220
- Issue
- 1
- Pages
- 82-92e1
- ISSN
- 1072-7515 (ISSN-L)
- OpenAlex
- W2103925331
- Cited by
- 560
- References
- 28
- FWCI
- 11.35
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.