Analysis of tear glucose concentration with electrospray ionization mass spectrometry
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
We have developed a mass spectrometry-based method that allows one to accurately determine the glucose concentration of tear fluid. We used a 1 microL micro-capillary to collect tear fluid from the tear meniscus with minimal irritation of the eye. We analyzed the 1 muL volume of collected tear fluid with liquid-chromatography electrospray ionization mass spectrometry with the use of D-glucose-6,6-d2 as an internal standard. Repeated measurements and a recovery experiment on pooled, onion-induced tears showed that the analysis of the glucose in tears was precise (4% relative standard deviation) and provided 100% recovery. We found the tear glucose concentration of one fasting nondiabetic subject to be 13 to 51 microM while the onion-induced tear glucose concentration of a different nondiabetic subject to be 211 to 256 microM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Photonic Crystal Glucose-Sensing Material for Noninvasive Monitoring of Glucose in Tear Fluid
Alexeev, V. L., Das, S., Finegold, D. N., & Asher, S. A. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.039701 · Cited by 370 · cited 1×
“artificial°tear°solution°[4]°showed°an°average°glucose concentration of 0.”
Self-citationClinical Trial of a Noninvasive Contact Lens Glucose Sensor
March, W. F., Mueller, A., & Herbrechtsmeier, P. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.782 · Cited by 74
Cited by
Willcox, M. D. P., Argüeso, P., Georgiev, G. A., Holopainen, J. M., Laurie, G. W., Millar, T. J., Papas, E. B., Rolland, J. P., Schmidt, T. A., Stahl, U., et al. (2017) · The Ocular Surface · doi:10.1016/j.jtos.2017.03.006 · Cited by 995
Contact Lens Sensors in Ocular Diagnostics
Farandos, N. M., Yetisen, A. K., Monteiro, M. J., Lowe, C. R., & Yun, S. H. (2015) · Advanced Healthcare Materials · doi:10.1002/adhm.201400504 · Cited by 466
From Diagnosis to Treatment: Recent Advances in Patient-Friendly Biosensors and Implantable Devices
Li, P., Lee, G.-H., Kim, S. Y., Kwon, S. Y., Kim, H.-R., & Park, S. (2021) · ACS Nano · doi:10.1021/acsnano.0c06688 · Cited by 359
Tear analysis in ocular surface diseases
Zhou, L., & Beuerman, R. W. (2012) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2012.06.002 · Cited by 318
Eyeglasses-based tear biosensing system: Non-invasive detection of alcohol, vitamins and glucose
Sempionatto, J. R., Brazaca, L. C., García-Carmona, L., Bolat, G., Campbell, A. S., Martin, A., Tang, G., Shah, R., Mishra, R. K., Kim, J., et al. (2019) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2019.04.058 · Cited by 315
Metadata
- Authors
- Taormina, C. R., Baca, J. T., Asher, S. A., Grabowski, J. J., & Finegold, D. N.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-02-01
- Volume
- 18
- Issue
- 2
- Pages
- 332-336
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2018773803
- Cited by
- 99
- References
- 2
- FWCI
- 1.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.