The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Ionization and transmission efficiency in an electrospray ionization—mass spectrometry interface
Abstract
The ionization and transmission efficiencies of an electrospray ionization (ESI) interface were investigated to advance the understanding of how these factors affect mass spectrometry (MS) sensitivity. In addition, the effects of the ES emitter distance to the inlet, solution flow rate, and inlet temperature were characterized. Quantitative measurements of ES current loss throughout the ESI interface were accomplished by electrically isolating the front surface of the interface from the inner wall of the heated inlet capillary, enabling losses on the two surfaces to be distinguished. In addition, the ES current lost to the front surface of the ESI interface was spatially profiled with a linear array of 340-microm-diameter electrodes placed adjacent to the inlet capillary entrance. Current transmitted as gas-phase ions was differentiated from charged droplets and solvent clusters by measuring sensitivity with a single quadrupole mass spectrometer. The study revealed a large sampling efficiency into the inlet capillary (>90% at an emitter distance of 1 mm), a global rather than a local gas dynamic effect on the shape of the ES plume resulting from the gas flow conductance limit of the inlet capillary, a large (>80%) loss of analyte ions after transmission through the inlet arising from incomplete desolvation at a solution flow rate of 1.0 microL/min, and a decrease in analyte ions peak intensity at lower temperatures, despite a large increase in ES current transmission efficiency.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray ion source. Another variation on the free-jet theme
Yamashita, M., & Fenn, J. B. (1984) · The Journal of Physical Chemistry · doi:10.1021/j150664a002 · Cited by 2,082
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Electrospray ionization–principles and practice
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1990) · Mass Spectrometry Reviews · doi:10.1002/mas.1280090103 · Cited by 1,569
Practical implications of some recent studies in electrospray ionization fundamentals
Cech, N. B., & Enke, C. G. (2001) · Mass Spectrometry Reviews · doi:10.1002/mas.10008 · Cited by 1,435
Electrospray ionization mass spectrometry : fundamentals, instrumentation, and applications
Cole, R. B. (1997) · Wiley eBooks · Cited by 1,140
New developments in biochemical mass spectrometry: electrospray ionization
Smith, R. D., Loo, J. A., Edmonds, C. G., Barinaga, C. J., & Udseth, H. R. (1990) · Analytical Chemistry · doi:10.1021/ac00208a002 · Cited by 1,051
Self-citationElectrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
The current emitted by highly conducting Taylor cones
De La Mora, J. F., & Loscertales, I. G. (1994) · Journal of Fluid Mechanics · doi:10.1017/s0022112094003472 · Cited by 884
From ions in solution to ions in the gas phase - the mechanism of electrospray mass spectrometry
Kebarle, P., & Tang, L. (1993) · Analytical Chemistry · doi:10.1021/ac00070a001 · Cited by 781
Inhomogeneous RF Fields: A Versatile Tool for the Study of Processes with Slow Ions
Gerlich, D. (1992) · Advances in Chemical Physics · doi:10.1002/9780470141397.ch1 · Cited by 685
A brief overview of the present status of the mechanisms involved in electrospray mass spectrometry
Kebarle, P. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<804::aid-jms22>3.0.co;2-q · Cited by 675
Schmidt, A., Karas, M., & Dülcks, T. (2003) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(03)00128-4 · Cited by 534
State-Selected and State-to-State Ion−Molecule Reaction Dynamics
Ng, C.-Y. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp020055i · Cited by 429
Mechanistic aspects of electrospray ionization
Bruins, A. P. (1998) · Journal of Chromatography A · doi:10.1016/s0021-9673(97)01110-2 · Cited by 368
Some tenets pertaining to electrospray ionization mass spectrometry
Cole, R. B. (2000) · Journal of Mass Spectrometry · doi:10.1002/1096-9888(200007)35:7<763::aid-jms16>3.0.co;2-# · Cited by 365
Qian, W.-J., Jacobs, J. M., Liu, T., Camp, D. G., & Smith, R. D. (2006) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m600162-mcp200 · Cited by 362
Self-citationAn electrospray‐ionization mass spectrometer with new features
Chowdhury, S. K., Katta, V., & Chait, B. T. (1990) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.1290040305 · Cited by 323
Tang, K., Page, J. S., & Smith, R. D. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.04.034 · Cited by 262
Self-citationSchaffer, S. A., Tang, K., Anderson, G. A., Prior, D. C., Udseth, H. R., & Smith, R. D. (1997) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19971030)11:16<1813::aid-rcm87>3.0.co;2-d · Cited by 262
Self-citationKelly, R. T., Page, J. S., Luo, Q., Moore, R. J., Orton, D. J., Tang, K., & Smith, R. D. (2006) · Analytical Chemistry · doi:10.1021/ac061133r · Cited by 240
Self-citationShen, Y., Zhang, R., Moore, R. J., Kim, J., Metz, T. O., Hixson, K. K., Zhao, R., Livesay, E. A., Udseth, H. R., & Smith, R. D. (2005) · Analytical Chemistry · doi:10.1021/ac0483062 · Cited by 230
Self-citationDesign and Implementation of a New Electrodynamic Ion Funnel
Kim, T., Tolmachev, A. V., Harkewicz, R., Prior, D. C., Anderson, G., Udseth, H. R., Smith, R. D., Bailey, T. H., Rakov, S., & Futrell, J. H. (2000) · Analytical Chemistry · doi:10.1021/ac991412x · Cited by 201
Self-citationElectrospray ionization source geometry for mass spectrometry: past, present, and future
Manisali, I., Chen, D. D. Y., & Schneider, B. B. (2005) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2005.07.007 · Cited by 140
State-selected and state-to-state ion—molecule reaction dynamics. Part 1. Experiment
Whitaker, B. (1992) · Chemical Engineering Science · doi:10.1016/0009-2509(92)85129-y · Cited by 104
Li, L. Y.-T., Campbell, D. A., Bennett, P. K., & Henion, J. D. (1996) · Analytical Chemistry · doi:10.1021/ac960375w · Cited by 87
Wahl, J. H., Goodlett, D. R., Udseth, H. R., et al. (1993) · Electrophoresis · doi:10.1002/elps.1150140170 · Cited by 86
The continuing evolution of shotgun proteomics.
Swanson, S., & Washburn, M. (2005) · Drug Discovery Today · doi:10.1016/s1359-6446(05)03450-1 · Cited by 77
Kelly, R., Page, J. S., Tang, K., & Smith, R. D. (2007) · Analytical Chemistry · doi:10.1021/ac062417e · Cited by 58
Self-citationReduced elution speed detection for capillary electrophoresis/mass spectrometry
Goodlett, D. R., Wahl, J. H., Udseth, H. R., et al. (1993) · Journal of Microcolumn Separations · doi:10.1002/mcs.1220050109 · Cited by 57
Cited by
Accelerated Reaction Kinetics in Microdroplets: Overview and Recent Developments
Wei, Z., Li, Y., Cooks, R. G., & Yan, X. (2020) · Annual Review of Physical Chemistry · doi:10.1146/annurev-physchem-121319-110654 · Cited by 631
Mass spectrometry-based proteomics: existing capabilities and future directions
Angel, T. E., Aryal, U. K., Hengel, S. M., Baker, E. S., Kelly, R. T., Robinson, E. W., & Smith, R. D. (2012) · Chemical Society Reviews · doi:10.1039/c2cs15331a · Cited by 441
Self-citationTutorial review on validation of liquid chromatography–mass spectrometry methods: Part II
Kruve, A., Rebane, R., Kipper, K., Oldekop, M.-L., Evard, H., Herodes, K., Ravio, P., & Leito, I. (2015) · Analytica Chimica Acta · doi:10.1016/j.aca.2015.02.016 · Cited by 338
Atmospheric pressure ion sources
Covey, T. R., Thomson, B. A., & Schneider, B. B. (2009) · Mass Spectrometry Reviews · doi:10.1002/mas.20246 · Cited by 264
Storbeck, K.-H., Gilligan, L., Jenkinson, C., Baranowski, E. S., Quanson, J. L., Arlt, W., & Taylor, A. E. (2018) · Journal of Chromatography B · doi:10.1016/j.jchromb.2018.03.033 · Cited by 49
Metadata
- Authors
- Page, J. S., Kelly, R. T., Tang, K., & Smith, R. D.
- Venue
- Journal of the American Society for Mass Spectrometry
- Publisher
- American Chemical Society (ACS)
- Published
- 2007-09-01
- Volume
- 18
- Issue
- 9
- Pages
- 1582-1590
- ISSN
- 1044-0305 (ISSN-L)
- OpenAlex
- W2172102798
- Cited by
- 265
- References
- 29
- FWCI
- 5.08
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.