Loading of the knee joint during activities of daily living measured in vivo in five subjects
Abstract
Detailed knowledge about loading of the knee joint is essential for preclinical testing of implants, validation of musculoskeletal models and biomechanical understanding of the knee joint. The contact forces and moments acting on the tibial component were therefore measured in 5 subjects in vivo by an instrumented knee implant during various activities of daily living. Average peak resultant forces, in percent of body weight, were highest during stair descending (346% BW), followed by stair ascending (316% BW), level walking (261% BW), one legged stance (259% BW), knee bending (253% BW), standing up (246% BW), sitting down (225% BW) and two legged stance (107% BW). Peak shear forces were about 10-20 times smaller than the axial force. Resultant forces acted almost vertically on the tibial plateau even during high flexion. Highest moments acted in the frontal plane with a typical peak to peak range -2.91% BWm (adduction moment) to 1.61% BWm (abduction moment) throughout all activities. Peak flexion/extension moments ranged between -0.44% BWm (extension moment) and 3.16% BWm (flexion moment). Peak external/internal torques lay between -1.1% BWm (internal torque) and 0.53% BWm (external torque). The knee joint is highly loaded during daily life. In general, resultant contact forces during dynamic activities were lower than the ones predicted by many mathematical models, but lay in a similar range as measured in vivo by others. Some of the observed load components were much higher than those currently applied when testing knee implants.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This loading condition represented a worst-case outcome for the ACL during walking (Kutzner et al., 2010).”
From The Femoral Tunnel Drilling Angle at 45° Coronal and 45° Sagittal Provided the Lowest Peak Stress and Strain on the Bone Tunnels and Anterior Cruciate Ligament Graft (2021) · cites this paper as Kutzner et al., 2010
Citations
Cites
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,062
The prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A. A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 500
Tibio‐femoral loading during human gait and stair climbing
Taylor, W. R., Heller, M. O. W., Bergmann, G., & Duda, G. N. (2003) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2003.09.003 · Cited by 377
Knee and hip kinetics during normal stair climbing
Costigan, P. A., Deluzio, K. J., & WYSS, U. P. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00201-6 · Cited by 325
Function of the knee joint in various activities.
Morrison, J. B. (1969) · PubMed · Cited by 318
Alignment of curves by dynamic time warping
Wang, K., & Gasser, T. (1997) · The Annals of Statistics · doi:10.1214/aos/1069362747 · Cited by 296
Mündermann, A., Dyrby, C. O., DʼLima, D. D., Colwell, C. W., & Andriacchi, T. P. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20655 · Cited by 250
Taylor, S. J. G., Walker, P. S., Perry, J. S., Cannon, S. R., & WOLEDGE, R. C. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90009-2 · Cited by 246
Tibial Forces Measured In Vivo After Total Knee Arthroplasty
DʼLima, D. D., Patil, S. S., Steklov, N., Slamin, J. E., & Colwell, C. W. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.07.011 · Cited by 232
Heinlein, B., Kutzner, I., Graichen, F., Bender, A., Rohlmann, A., Halder, A. M., Beier, A., & Bergmann, G. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.011 · Cited by 201
Cited by
Sorted by citations
Items 101–200 of 797
Rivière, C., Ollivier, M. P., Girerd, D., Argenson, J., & Parratte, S. (2017) · The Knee · doi:10.1016/j.knee.2017.03.001 · Cited by 53
Evaluating knee replacement mechanics during ADL with PID-controlled dynamic finite element analysis
Fitzpatrick, C. K., Baldwin, M. A., Clary, C. W., Maletsky, L. P., & Rullkoetter, P. J. (2012) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.684242 · Cited by 53
Karpiński, R., Szabelski, J., & Maksymiuk, J. (2019) · Materials · doi:10.3390/ma12233963 · Cited by 52
DLP printing of BT/HA nanocomposite ceramic scaffolds using low refractive index BT crystals
Xue, R., Yuan, P., Zhao, B. Y., Jing, F., Kou, X., Yue, W., Wang, Y., Wang, D., Sewvandi, G. A., & Hu, D. (2023) · Journal of Materiomics · doi:10.1016/j.jmat.2023.11.004 · Cited by 52
Miller, R. H., Brandon, S., & Deluzio, K. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023151 · Cited by 49
Schwiesau, J., Schilling, C., Kaddick, C., Utzschneider, S., Jansson, V., Fritz, B., Blömer, W., & Grupp, T. M. (2012) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2012.07.003 · Cited by 52
Kang, K.-T., Koh, Y.-G., Son, J., Kwon, O.-R., Baek, C., Jung, S., & Park, K. K. (2016) · Bone and Joint Research · doi:10.1302/2046-3758.511.bjr-2016-0107.r1 · Cited by 51
Design analysis of a passive weight-support lower-extremity-exoskeleton with compliant knee-joint
Lee, K.-M., & Wang, D. (2015) · Proceedings - IEEE International Conference on Robotics and Automation/Proceedings · doi:10.1109/icra.2015.7139978 · Cited by 51
Evaluation of a musculoskeletal model with prosthetic knee through six experimental gait trials
Kia, M., Stylianou, A. P., & Guess, T. M. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2013.12.007 · Cited by 51
Xu, C. H., Silder, A., Ju, Z., Hughes, J. M., Unnikrishnan, G. U., Jaques Reifman, A., & Rakesh, V. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4034216 · Cited by 51
Determination of typical patterns from strongly varying signals
Bender, A., & Bergmann, G. (2011) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2011.560841 · Cited by 51
Halonen, K. S., Mononen, M. E., Jurvelin, J. S., Töyräs, J., Kłodowski, A., Kulmala, J., & Korhonen, R. K. (2016) · Journal of Biomechanical Engineering · doi:10.1115/1.4033516 · Cited by 50
Metal-backedversusall-polyethylene unicompartmental knee arthroplasty
Scott, C. E. H., Eaton, M. J., Nutton, R. W., Wade, F. A., Evans, S. L., & Pankaj, P. (2017) · Bone and Joint Research · doi:10.1302/2046-3758.61.bjr-2016-0142.r1 · Cited by 50
Kang, K.-T., Son, J., Suh, D.-S., Kwon, S. K., Kwon, O.-R., & Koh, Y.-G. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.71.bjr-2017-0115.r2 · Cited by 50
Miller, M. A., TerBush, M. J., Goodheart, J. R., Izant, T. H., & Mann, K. A. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.04.016 · Cited by 49
Proximal tibial strain in medial unicompartmental knee replacements
Scott, C. E. H., Eaton, M. J., Nutton, R. W., Wade, F. A., Pankaj, P., & Evans, S. L. (2013) · The Bone & Joint Journal · doi:10.1302/0301-620x.95b10.31644 · Cited by 49
Telfer, S., Lange, M. J., & Sudduth, A. S. M. (2017) · Gait & Posture · doi:10.1016/j.gaitpost.2017.08.025 · Cited by 48
Comparison between kinetic and kinetic-kinematic driven knee joint finite element models
Bolcos, P. O., Mononen, M. E., Mohammadi, A., Ebrahimi, M., Tanaka, M. S., Samaan, M. A., Souza, R. B., Li, X., Suomalainen, J., Jurvelin, J. S., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-35628-5 · Cited by 48
Zhang, K., Li, L., Yang, L., Shi, J., Zhu, L., Liang, H., Wang, X., Yang, X., & Jiang, Q. Y. (2019) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-019-1255-1 · Cited by 48
Weight Bearing After a Periarticular Fracture
Haller, J. M., Potter, M. Q., & Kubiak, E. N. (2013) · Orthopedic Clinics of North America · doi:10.1016/j.ocl.2013.06.005 · Cited by 47
Mechanics of post‐cam engagement during simulated dynamic activity
Fitzpatrick, C. K., Clary, C. W., Cyr, A. J., Maletsky, L. P., & Rullkoetter, P. J. (2013) · Journal of Orthopaedic Research® · doi:10.1002/jor.22366 · Cited by 47
Liukkonen, M. K., Mononen, M. E., Klets, O., Arokoski, J. P., Saarakkala, S. S., & Korhonen, R. K. (2017) · Scientific Reports · doi:10.1038/s41598-017-09013-7 · Cited by 47
A Novel Experimental Knee-Pain Model Affects Perceived Pain and Movement Biomechanics
Seeley, M. K., Park, J., King, D., & Hopkins, J. T. (2013) · Journal of Athletic Training · doi:10.4085/1062-6050-48.2.02 · Cited by 46
Poh, S. C., Yew, K. S. A., Wong, P.-L. K., Koh, S.-B. J., Chia, S., Fook-Chong, S. M. C., & Howe, T.-S. (2011) · The Knee · doi:10.1016/j.knee.2010.12.008 · Cited by 46
Kang, K., Kwon, S. K., Son, J., Kwon, O., Lee, J., & Koh, Y. (2018) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-018-4925-3 · Cited by 46
Keogh, J. W., Grigg, J., & Vertullo, C. J. (2018) · PeerJ · doi:10.7717/peerj.4738 · Cited by 45
Dual-Joint Modeling for Estimation of Total Knee Replacement Contact Forces During Locomotion
Hast, M. W., & Piazza, S. J. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023320 · Cited by 45
Marouane, H., Shirazi-Adl, A., & Adouni, M. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.12.016 · Cited by 44
Validation of a new computational 6-DOF knee simulator during dynamic activities
Fitzpatrick, C. K., Maag, C., Clary, C. W., Amber, M., Langhorn, J., & Rullkoetter, P. J. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.07.040 · Cited by 43
Sagittal Stability and Implant Design Affect Patient Reported Outcomes After Total Knee Arthroplasty
Jones, C. W., Jacobs, H., Shumborski, S. J., Talbot, S., Redgment, A., Brighton, R. W., & Walter, W. L. (2019) · The Journal of Arthroplasty · doi:10.1016/j.arth.2019.10.020 · Cited by 43
Alnahdi, A. H., Zeni, J., & Snyder‐Mackler, L. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-015-3827-x · Cited by 42
Ali, N. F., Andersen, M. S., Rasmussen, J., Robertson, D. G. E., & Rouhi, G. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2012.758718 · Cited by 42
Anisotropy in the Viscoelastic Response of Knee Meniscus Cartilage
Coluccino, L., Peres, C., Gottardi, R., Bianchini, P., Diaspro, A., & Ceseracciu, L. (2016) · Journal of Applied Biomaterials & Functional Materials · doi:10.5301/jabfm.5000319 · Cited by 42
Miramini, S., Smith, D. W., Zhang, L., & Gardiner, B. S. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.05.018 · Cited by 42
Pagani, S., Liverani, E., Giavaresi, G., Luca, A. D., Belvedere, C., Fortunato, A., Leardini, A., Fini, M., Tomesani, L., & Caravaggi, P. (2021) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34857 · Cited by 42
Evaluation of the effect of bone plate modulus on the early bone healing of fractured tibia
Zaheer, M. U., Mehboob, H., Mehboob, A., & Chang, S. (2022) · Composites Part B Engineering · doi:10.1016/j.compositesb.2022.109668 · Cited by 41
Instrumented hip implants: Electric supply systems
dos Santos, M. P. S., Ferreira, J., Ramos, A. M., Simöes, J. A., Morais, R., Silva, N. M., Santos, P. M. D., Reis, M. J. C. S., & Oliveira, T. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.08.002 · Cited by 47
Worsley, P. R., Stokes, M. J., & Taylor, M. (2010) · Gait & Posture · doi:10.1016/j.gaitpost.2010.11.018 · Cited by 41
Gender differences in the knee joint loadings during gait
Obrębska, P., Skubich, J., & Piszczatowski, S. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.05.017 · Cited by 40
Liang, W., Wang, F., Fan, A., Zhao, W., Yao, W., & Yang, P. (2023) · Sensors · doi:10.3390/s23094229 · Cited by 48
Suh, D.-S., Kang, K.-T., Son, J., Kwon, O.-R., Baek, C., & Koh, Y.-G. (2017) · Bone and Joint Research · doi:10.1302/2046-3758.611.bjr-2016-0088.r2 · Cited by 39
Kang, K., Son, J., Baek, C., Kwon, O., & Koh, Y. (2018) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-018-2884-2 · Cited by 39
Structural design optimization of knee replacement implants for Additive Manufacturing
Peto, M., Ramírez-Cedillo, E., Hernández, A., & Siller, H. R. (2019) · Procedia Manufacturing · doi:10.1016/j.promfg.2019.06.222 · Cited by 41
In vivo measurement of shoulder joint loads during walking with crutches
Westerhoff, P., Graichen, F., Bender, A., Halder, A. M., Beier, A., Rohlmann, A., & Bergmann, G. (2012) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2012.03.004 · Cited by 39
Park, H. J., Chang, M. J., Cho, H., Hong, E., Kim, T. W., Chang, C. B., Bae, T. S., Kwak, D., & Kang, S. (2022) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2022.09.009 · Cited by 38
Age‐related optimization of screw placement for reduced loosening risk in locked plating
MacLeod, A. R., Simpson, H., & Pankaj, P. (2016) · Journal of Orthopaedic Research® · doi:10.1002/jor.23193 · Cited by 38
Chen, P., Lu, H., Shen, H., Wang, W., Ni, B., & Chen, J. (2017) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-017-0531-1 · Cited by 38
Koh, Y.-G., Son, J., Kwon, S. K., Kim, H.-J., Kwon, O.-R., & Kang, K.-T. (2017) · Bone and Joint Research · doi:10.1302/2046-3758.69.bjr-2016-0250.r1 · Cited by 38
Esrafilian, A., Stenroth, L., Mononen, M. E., Vartiainen, P., Tanska, P., Karjalainen, P. A., Suomalainen, J., Arokoski, J. P., Saxby, D. J., Lloyd, D. G., et al. (2022) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2022.3156018 · Cited by 38
In vitro evidence of the structural optimization of the human skeletal bones
Cristofolini, L. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.010 · Cited by 38
Muscle recruitment strategies can reduce joint loading during level walking
van Veen, B., Montefiori, E., Modenese, L., Mazzà, C., & Viceconti, M. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109368 · Cited by 37
Consistency Among Musculoskeletal Models: Caveat Utilitor
Wagner, D. W., Stepanyan, V., Shippen, J. M., DeMers, M. S., Gibbons, R., Andrews, B., Creasey, G. H., & Beaupré, G. S. (2013) · Annals of Biomedical Engineering · doi:10.1007/s10439-013-0843-1 · Cited by 37
Lundberg, H. J., Foucher, K. C., Andriacchi, T. P., & Wimmer, M. A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.01.015 · Cited by 36
Bobbert, M. F., Kistemaker, D. A., Vaz, M. A., & Ackermann, M. (2016) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2016.06.008 · Cited by 36
Kłodowski, A., Mononen, M. E., Kulmala, J., Valkeapää, A. I., Korhonen, R. K., Avela, J., Kiviranta, I., Jurvelin, J. S., & Mikkola, A. (2015) · Multibody System Dynamics · doi:10.1007/s11044-015-9470-y · Cited by 36
Wear Testing of Moderate Activities of Daily Living Using In Vivo Measured Knee Joint Loading
Reinders, J., Sonntag, R., Vot, L., Gibney, C., Nowack, M., & Kretzer, J. P. (2015) · PLoS ONE · doi:10.1371/journal.pone.0123155 · Cited by 36
Meng, Q., Jin, Z. M., Wilcox, R. K., & Fisher, J. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914559737 · Cited by 36
Fitzpatrick, C. K., Hemelaar, P., & Taylor, M. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.02.018 · Cited by 35
Nie, Y., Ma, J., Huang, Z., Xu, B., Tang, S., Shen, B., Kraus, V. B., & Pei, F. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.12.004 · Cited by 35
Schellenberg, F., Taylor, W. R., Trepczynski, A., List, R., Kutzner, I., Schütz, P., Duda, G. N., & Lorenzetti, S. (2018) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2018.09.004 · Cited by 35
Application of adult mesenchymal stem cells in bone and vascular tissue engineering
Trávníčková, M., & Bačáková, L. (2018) · Physiological Research · doi:10.33549/physiolres.933820 · Cited by 35
Waiteman, M. C., Chia, L., Ducatti, M. H. M., Bazett-Jones, D. M., Pappas, E., de Azevedo, F. M., & Briani, R. V. (2022) · Sports Medicine - Open · doi:10.1186/s40798-022-00536-6 · Cited by 38
Trabecular bone patterning in the hominoid distal femur
Georgiou, L., Kivell, T. L., Pahr, D. H., & Skinner, M. M. (2018) · PeerJ · doi:10.7717/peerj.5156 · Cited by 34
Release of the medial collateral ligament is mandatory in medial open-wedge high tibial osteotomy
Seitz, A. M., Nelitz, M., Ignatius, A. A., & Dürselen, L. (2018) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-018-5167-0 · Cited by 34
Warnecke, D., Meßemer, M., de Roy, L., Stein, S., Gentilini, C., Walker, R. W., Skaer, N., Ignatius, A. A., & Dürselen, L. (2019) · Scientific Reports · doi:10.1038/s41598-019-42254-2 · Cited by 35
Smith, S. H. L., Reilly, P., & Bull, A. M. J. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.109451 · Cited by 34
Asaeda, M., Deie, M., Fujita, N., Kono, Y., Terai, C., Kuwahara, W., Watanabe, H., Kimura, H., Adachi, N., Sunagawa, T., et al. (2017) · The Knee · doi:10.1016/j.knee.2017.01.001 · Cited by 33
Liukkonen, M. K., Mononen, M. E., Vartiainen, P., Kaukinen, P., Bragge, T., Suomalainen, J., Malo, M. K. H., Venesmaa, S., Käkelä, P., Pihlajamäki, J., et al. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4038330 · Cited by 33
Kang, K.-T., Koh, Y.-G., Son, J., Kwon, O.-R., Lee, J., & Kwon, S. K. (2018) · Bone and Joint Research · doi:10.1302/2046-3758.71.bjr-2017-0143.r1 · Cited by 33
Warnecke, D., Stein, S., Haffner‐Luntzer, M., de Roy, L., Skaer, N., Walker, R. W., Kessler, O., Ignatius, A. A., & Dürselen, L. (2018) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2018.06.041 · Cited by 33
Danese, I., Pankaj, P., & Scott, C. E. H. (2019) · Bone and Joint Research · doi:10.1302/2046-3758.82.bjr-2018-0186.r2 · Cited by 33
Kebbach, M., Darowski, M., Krueger, S., Schilling, C., Grupp, T. M., Bader, R., & Geier, A. (2020) · Materials · doi:10.3390/ma13102365 · Cited by 38
Dehoust, J., Münch, M., Seide, K., Barth, T., & Frosch, K. (2020) · European Journal of Trauma and Emergency Surgery · doi:10.1007/s00068-020-01538-3 · Cited by 33
Evaluation of a geometry-based knee joint compared to a planar knee joint
Sandholm, A., Schwartz, C., Pronost, N., de Zee, M., Voigt, M., & Thalmann, D. (2011) · The Visual Computer · doi:10.1007/s00371-010-0538-7 · Cited by 33
Jung, Y., Phan, C.-B., & Koo, S. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4032414 · Cited by 33
Yang, P.-F., Kriechbaumer, A., Albracht, K., Sanno, M., Ganse, B., Koy, T., Shang, P., Brüggemann, G.-P., Müller, L. P., & Rittweger, J. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.031 · Cited by 32
Holder, J., van Drongelen, S., Uhlrich, S. D., Herrmann, E. M., Meurer, A., & Stief, F. (2023) · Scientific Reports · doi:10.1038/s41598-023-30058-4 · Cited by 32
Leitch, K. M., Birmingham, T. B., Dunning, C. E., & Giffin, J. R. (2015) · Gait & Posture · doi:10.1016/j.gaitpost.2015.05.005 · Cited by 32
Multi-Joint Compensatory Effects of Unilateral Total Knee Arthroplasty During High-Demand Tasks
Gaffney, B. M. M., Harris, M. D., Davidson, B. S., Stevens‐Lapsley, J. E., Christiansen, C. L., & Shelburne, K. B. (2015) · Annals of Biomedical Engineering · doi:10.1007/s10439-015-1524-z · Cited by 32
Sole, G., Pataky, T. C., Tengman, E., & Häger, C. K. (2016) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2016.12.005 · Cited by 32
Clinical potential of implantable wireless sensors for orthopedic treatments
Karipott, S. S., Nelson, B. D., Guldberg, R. E., & Ong, K. G. (2018) · Expert Review of Medical Devices · doi:10.1080/17434440.2018.1454310 · Cited by 32
Medial Compartment Decompression by Proximal Fibular Osteotomy: A Biomechanical Cadaver Study
Baldini, T. H., Roberts, J., Hao, J., Hunt, K. J., Dayton, M. R., & Hogan, C. A. (2018) · Orthopedics · doi:10.3928/01477447-20180424-05 · Cited by 32
Inyang, A. O., & Vaughan, C. L. (2020) · Materials · doi:10.3390/ma13081886 · Cited by 32
Leitch, K. M., Birmingham, T. B., Dunning, C. E., & Giffin, J. R. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.01.024 · Cited by 32
Friction properties of a new silk fibroin scaffold for meniscal replacement
Warnecke, D., Schild, N., Klose, S., Joos, H., Brenner, R. E., Kessler, O., Skaer, N., Walker, R., Freutel, M., Ignatius, A. A., et al. (2017) · Tribology International · doi:10.1016/j.triboint.2017.01.038 · Cited by 32
van der Vusse, M., Kalmet, P. H. S., Bastiaenen, C. H. G., Horn, Y., Brink, P. R. G., & Seelen, H. A. M. (2017) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-017-2718-7 · Cited by 32
Bersini, S., Sansone, V. C., & Frigo, C. (2015) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2015.1051972 · Cited by 32
Berahmani, S., Janssen, D. W., Wolfson, D., Malefijt, M. D. W., Fitzpatrick, C. K., Rullkoetter, P. J., & Verdonschot, N. J. J. (2015) · Journal of Orthopaedic Research® · doi:10.1002/jor.23074 · Cited by 31
Effect of femoral component position on biomechanical outcomes of unicompartmental knee arthroplasty
Kang, K., Son, J., Koh, Y., Kwon, O., Kwon, S. K., Lee, Y. J., & Park, K. K. (2018) · The Knee · doi:10.1016/j.knee.2018.03.003 · Cited by 31
Wang, S., Kazunori, H. A. S. E., Kita, S., & Ogaya, S. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.957435 · Cited by 31
Melli, V., Juszczyk, M., Sandrini, E., Bolelli, G., Bonferroni, B., Lusvarghi, L., Cigada, A., Manfredini, T., & Nardo, L. D. (2015) · Journal of Materials Science Materials in Medicine · doi:10.1007/s10856-014-5332-z · Cited by 31
Instrumented Knee Prosthesis for Force and Kinematics Measurements
Arami, A., Simoncini, M., Atasoy, O., Ali, S., Hasenkamp, W., Bertsch, A., Meurville, E., Tanner, S., Renaud, P., Dehollain, C., et al. (2013) · IEEE Transactions on Automation Science and Engineering · doi:10.1109/tase.2012.2226030 · Cited by 31
Feng, X., Lin, G., Fang, C. X., Lu, W. W., Chen, B., & Leung, F. K. L. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24286 · Cited by 31
Guo, N., Smith, C. R., Schütz, P., Trepczynski, A., Moewis, P., Damm, P., Maas, A., Grupp, T. M., Taylor, W. R., & Nasab, S. H. H. (2024) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2024.1352794 · Cited by 30
Alterations in Knee Kinematics After Partial Medial Meniscectomy Are Activity Dependent
Edd, S. N., Netravali, N. A., Favre, J., Giori, N. J., & Andriacchi, T. P. (2015) · The American Journal of Sports Medicine · doi:10.1177/0363546515577360 · Cited by 30
Stiffness and shape of the ACL graft affects tunnel enlargement and graft wear
Wang, H., Zhang, B., & Cheng, C. (2019) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-019-05772-0 · Cited by 30
Hossain, N. A., Yamomo, G. G., Willing, R. T., & Towfighian, S. (2021) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2021.3049327 · Cited by 30
Adouni, M., & Shirazi-Adl, A. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.09.035 · Cited by 30
Cui, L., Li, H., Gong, C., Huang, J., & Xiong, D. (2022) · Ceramics International · doi:10.1016/j.ceramint.2022.05.309 · Cited by 30
Dreyer, M. J., Trepczynski, A., Nasab, S. H. H., Kutzner, I., Schütz, P., Weisse, B., Dymke, J., Postolka, B., Moewis, P., Bergmann, G., et al. (2022) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2022.111171 · Cited by 29
Metadata
- Authors
- Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- Berlin-Brandenburger Centrum für Regenerative Therapien (DE)
- Corresponding author
- Kutzner, I.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 43
- Issue
- 11
- Pages
- 2164-2173
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1972617433
- Cited by
- 798
- References
- 19
- Citations by year
- 2026: 55 · 2025: 48 · 2024: 42 · 2023: 38 · 2022: 66 · 2021: 49 · 2020: 52 · 2019: 70 · 2018: 65 · 2017: 56 · 2016: 49 · 2015: 49 · 2014: 51 · 2013: 50 · 2012: 28
- FWCI
- 36.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- knee joint loading, activities of daily living, in vivo measurement, shear force, stair climbing, walking, knee flexion
- MeSH terms
- Activities of Daily Living, Aged, Computer Simulation, Female, Humans, Knee Joint, Male, Middle Aged, Models, Biological, Stress, Mechanical, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review