The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Loading of the knee joint during activities of daily living measured in vivo in five subjects
Abstract
Detailed knowledge about loading of the knee joint is essential for preclinical testing of implants, validation of musculoskeletal models and biomechanical understanding of the knee joint. The contact forces and moments acting on the tibial component were therefore measured in 5 subjects in vivo by an instrumented knee implant during various activities of daily living. Average peak resultant forces, in percent of body weight, were highest during stair descending (346% BW), followed by stair ascending (316% BW), level walking (261% BW), one legged stance (259% BW), knee bending (253% BW), standing up (246% BW), sitting down (225% BW) and two legged stance (107% BW). Peak shear forces were about 10-20 times smaller than the axial force. Resultant forces acted almost vertically on the tibial plateau even during high flexion. Highest moments acted in the frontal plane with a typical peak to peak range -2.91% BWm (adduction moment) to 1.61% BWm (abduction moment) throughout all activities. Peak flexion/extension moments ranged between -0.44% BWm (extension moment) and 3.16% BWm (flexion moment). Peak external/internal torques lay between -1.1% BWm (internal torque) and 0.53% BWm (external torque). The knee joint is highly loaded during daily life. In general, resultant contact forces during dynamic activities were lower than the ones predicted by many mathematical models, but lay in a similar range as measured in vivo by others. Some of the observed load components were much higher than those currently applied when testing knee implants.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This loading condition represented a worst-case outcome for the ACL during walking (Kutzner et al., 2010).”
From The Femoral Tunnel Drilling Angle at 45° Coronal and 45° Sagittal Provided the Lowest Peak Stress and Strain on the Bone Tunnels and Anterior Cruciate Ligament Graft (2021) · cites this paper as Kutzner et al., 2010
Citations
Cites
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,062
The prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A. A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 500
Tibio‐femoral loading during human gait and stair climbing
Taylor, W. R., Heller, M. O. W., Bergmann, G., & Duda, G. N. (2003) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2003.09.003 · Cited by 377
Knee and hip kinetics during normal stair climbing
Costigan, P. A., Deluzio, K. J., & WYSS, U. P. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00201-6 · Cited by 325
Function of the knee joint in various activities.
Morrison, J. B. (1969) · PubMed · Cited by 318
Alignment of curves by dynamic time warping
Wang, K., & Gasser, T. (1997) · The Annals of Statistics · doi:10.1214/aos/1069362747 · Cited by 296
Mündermann, A., Dyrby, C. O., DʼLima, D. D., Colwell, C. W., & Andriacchi, T. P. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20655 · Cited by 250
Taylor, S. J. G., Walker, P. S., Perry, J. S., Cannon, S. R., & WOLEDGE, R. C. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90009-2 · Cited by 246
Tibial Forces Measured In Vivo After Total Knee Arthroplasty
DʼLima, D. D., Patil, S. S., Steklov, N., Slamin, J. E., & Colwell, C. W. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.07.011 · Cited by 232
Heinlein, B., Kutzner, I., Graichen, F., Bender, A., Rohlmann, A., Halder, A. M., Beier, A., & Bergmann, G. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.011 · Cited by 201
Cited by
Sorted by citations
Items 301–400 of 797
Berahmani, S., Hendriks, M. M. S., Wolfson, D., Wright, A., Janssen, D. W., & Verdonschot, N. J. J. (2017) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2017.07.043 · Cited by 17
Marouane, H., & Shirazi-Adl, A. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.02.006 · Cited by 17
Meireles, S., Reeves, N. D., Jones, R. K., Smith, C. R., Thelen, D. G., & Jonkers, I. (2019) · Journal of Applied Biomechanics · doi:10.1123/jab.2017-0159 · Cited by 17
Truhn, D., Brill, N., Braun, B. J., Merhof, D., Kuhl, C. K., Knobe, M., Thüring, J., & Nebelung, S. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.103428 · Cited by 17
Koh, Y., Park, K.-M., Kang, K., Kim, P. S., Lee, Y. H., Park, K. K., & Kang, K. (2021) · The Knee · doi:10.1016/j.knee.2021.01.004 · Cited by 16
Comparative analysis of tibial plateau fracture osteosynthesis: A finite element study
Ferre, L. S., Nisio, F. G. D., Mendonça, C. J. A., & Belo, I. M. (2022) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2022.105392 · Cited by 16
Zou, J., Zhang, X., Zhang, Y., Li, J., & Jin, Z. M. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.106099 · Cited by 16
Grupp, T. M., Pietschmann, M. F., Holderied, M., Scheele, C. B., Schröder, C., Jansson, V., & Müller, P. E. (2013) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2013.10.003 · Cited by 16
Razu, S. S., & Guess, T. M. (2017) · Journal of Biomechanical Engineering · doi:10.1115/1.4038507 · Cited by 16
Koh, Y., Son, J., Kwon, O., Kwon, S. K., & Kang, K. (2018) · BioMed Research International · doi:10.1155/2018/2438980 · Cited by 16
Koh, Y.-G., Lee, J.-A., Lee, H.-Y., Chun, H., Kim, H.-J., & Kang, K. (2019) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-019-05540-0 · Cited by 16
Loading conditions of the knee: what does it mean?
Becker, R., Kopf, S., & Karlsson, J. (2013) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-013-2741-3 · Cited by 16
Ding, S., Yu, P., Xu, P., Liu, Y., Xu, X., Sun, W. C., Xie, J., & Li, J. (2025) · Advanced Functional Materials · doi:10.1002/adfm.202505638 · Cited by 15
Abidin, N. A. Z., Wahab, A. H. A., Rahim, R. A. A., Kadir, M. R. A., & Ramlee, M. H. (2021) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-021-02419-6 · Cited by 15
Raimondo, G. D., Willems, M., Killen, B. A., Havashinezhadian, S., Turcot, K., Vanwanseele, B., & Jonkers, I. (2023) · Sensors · doi:10.3390/s23094484 · Cited by 16
Analysis of muscle activation patterns during transitions into and out of high knee flexion postures
Tennant, L. M., Maly, M. R., Callaghan, J. P., & Acker, S. M. (2014) · Journal of Electromyography and Kinesiology · doi:10.1016/j.jelekin.2014.06.011 · Cited by 16
Nazempour, A., Quisenberry, C. R., Wie, B. V., & Abu‐Lail, N. I. (2016) · Journal of Nanoscience and Nanotechnology · doi:10.1166/jnn.2016.12564 · Cited by 15
Chen, T., McCarthy, M. M., Guo, H., Warren, R. F., & Maher, S. A. (2018) · Journal of Biomechanical Engineering · doi:10.1115/1.4040121 · Cited by 15
Seo, H., Lim, D., Jang, Y. W., Kang, K. S., Lee, M. C., Lee, O.-S., Im, B.-E., & Lee, Y. S. (2019) · The Journal of Knee Surgery · doi:10.1055/s-0038-1676772 · Cited by 15
Gibbons, K. D., Clary, C. W., Rullkoetter, P. J., & Fitzpatrick, C. K. (2019) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2019.03.010 · Cited by 15
The detection of knee joint sounds at defined loads by means of vibroarthrography
Kalo, K., Niederer, D., Sus, R., Sohrabi, K., Banzer, W. B., Groß, V., & Vogt, L. (2020) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2020.01.021 · Cited by 15
Samsami, S., Herrmann, S., Pätzold, R., Winkler, M., & Augat, P. (2020) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.07.026 · Cited by 15
TKA wear testing input after kinematic and dynamic meta-analysis: Technique and proof of concept
Franta, L., Kronek, J., & Suchánek, J. (2011) · Wear · doi:10.1016/j.wear.2011.02.026 · Cited by 15
Gíslason, M. K., Coupaud, S., SASAGAWA, K., TANABE, Y., Purcell, M., Allan, D., & Tanner, K. E. (2014) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411914522438 · Cited by 15
Steinmann pin augmentation versus locking plate constructs
Ruskin, J. B., Caravaggi, P., Beebe, K. S., Corgan, S., Chen, L., Yoon, R. S., Patterson, F. R., & Hwang, J. S. (2016) · Journal of Orthopaedics and Traumatology · doi:10.1007/s10195-016-0394-y · Cited by 15
Navacchia, A., Clary, C. W., Wilson, H., Behnam, Y. A., & Rullkoetter, P. J. (2018) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2018.06.024 · Cited by 15
Koh, Y., Nam, J., & Kang, K. (2018) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-018-0167-z · Cited by 15
Chen, G., Xu, B., Xie, J., Nie, Y., Tang, S., Ma, J., Huang, Q., Zhou, Z., Shen, B., Li, X., et al. (2019) · BioMed Research International · doi:10.1155/2019/4575424 · Cited by 15
Koh, Y., Hong, H.-T., Lee, H.-Y., Kim, H., & Kang, K. (2019) · The Journal of Knee Surgery · doi:10.1055/s-0039-1696958 · Cited by 14
Markström, J. L., Liebermann, D. G., Schelin, L., & Häger, C. K. (2022) · The American Journal of Sports Medicine · doi:10.1177/03635465221095236 · Cited by 14
Mann, K. A., Miller, M. A., Goodheart, J. R., Izant, T. H., & Cleary, R. J. (2013) · Journal of Orthopaedic Research® · doi:10.1002/jor.22534 · Cited by 14
Prado-Nóvoa, M., Pérez-Blanca, A., Espejo‐Reina, A., Espejo-Reina, M. J., & Espejo-Baena, A. (2020) · Scientific Reports · doi:10.1038/s41598-020-58656-6 · Cited by 14
Systematic review of computational modelling for biomechanics analysis of total knee replacement
Shu, L., Li, S., & Sugita, N. (2020) · Biosurface and Biotribology · doi:10.1049/bsbt.2019.0012 · Cited by 14
Wang, H., Zhang, M., & Cheng, C. (2020) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-020-01755-x · Cited by 14
Shriram, D., Yamako, G., Kumar, G. P., Chosa, E., Cui, F., & Subburaj, K. (2021) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-021-01440-w · Cited by 14
Biomechanical Changes in Gait Patterns of Patients with Grade II Medial Gonarthritis
Skvortsov, D. V., Николаевич, К. С., Призов, А. П., Altukhova, A., Troitskiy, A. V., & Леонидович, Л. Ф. (2021) · Diagnostics · doi:10.3390/diagnostics11071242 · Cited by 14
Jaeger, S., Eissler, M., Schwarze, M., Schonhoff, M., Kretzer, J. P., & Bitsch, R. G. (2022) · Bone and Joint Research · doi:10.1302/2046-3758.114.bjr-2021-0169.r1 · Cited by 14
Liao, J., Liu, X., Miramini, S., & Zhang, L. (2022) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2022.105904 · Cited by 14
Cleather, D. J., & Bull, A. M. J. (2012) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411911432104 · Cited by 14
Estimating total knee replacement joint load ratios from kinematics
Fitzpatrick, C. K., & Rullkoetter, P. J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.07.002 · Cited by 14
Sole, G., Tengman, E., Grip, H., & Häger, C. K. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.11.013 · Cited by 14
Beckwée, D., Vaes, P., Raeymaeckers, S., Shahabpour, M., Scheerlinck, T., & Bautmans, I. (2016) · Disability and Rehabilitation · doi:10.1080/09638288.2016.1212110 · Cited by 15
Grupp, T. M., Saleh, K. J., Holderied, M., Pfaff, A. M., Schilling, C., Schroeder, C., & Mihalko, W. M. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.04.031 · Cited by 14
Markerless Knee Joint Position Measurement Using Depth Data during Stair Walking
Ogawa, A., Mita, A., Yorozu, A., & Takahashi, M. (2017) · Sensors · doi:10.3390/s17112698 · Cited by 14
Koh, Y., Park, K.-M., & Kang, K. (2020) · BioMed Research International · doi:10.1155/2020/1829385 · Cited by 13
Shi, Q., Wang, H., He, K., Tao, M., & Cheng, C. (2022) · Frontiers in Veterinary Science · doi:10.3389/fvets.2022.1045785 · Cited by 13
Periarticular muscle status affects in vivo tibio-femoral joint loads after total knee arthroplasty
Winkler, T., Bell, L., Bender, A., Trepczynski, A., Duda, G. N., Baur, A. J. D., & Damm, P. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1075357 · Cited by 13
Druel, J., Gelin, N., Ollivier, M. P., Roseren, F., Chabrand, P. R., Jacquet, C., & Argenson, J. (2024) · The Journal of Arthroplasty · doi:10.1016/j.arth.2024.02.047 · Cited by 13
Husen, M., Custers, R. J. H., Krych, A. J., & Saris, D. B. F. (2022) · Journal of Cartilage & Joint Preservation · doi:10.1016/j.jcjp.2022.100059 · Cited by 13
Ardestani, M. M., Chen, Z., Wang, L., Lian, Q., Liu, Y., He, J., Li, D., & Jin, Z. M. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.06.016 · Cited by 13
The design and pre-clinical evaluation of knee replacements for osteoarthritis
Walker, P. S. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.12.012 · Cited by 13
Allan, R. N., Woodburn, J., Telfer, S., Abbott, M., & Steultjens, M. P. M. (2017) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411917691318 · Cited by 13
Kang, K., Son, J., Kwon, O., & Koh, Y. (2017) · JAAOS Global Research and Reviews · doi:10.5435/jaaosglobal-d-17-00020 · Cited by 13
Jagtenberg, E. M., Kalmet, P. H. S., de Krom, M. A. P., Blokhuis, T. J., Seelen, H. A. M., & Poeze, M. (2020) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-2721 · Cited by 13
Jahangir, S., Mohammadi, A., Mononen, M. E., Hirvasniemi, J., Suomalainen, J., Saarakkala, S. S., Korhonen, R. K., & Tanska, P. (2022) · Annals of Biomedical Engineering · doi:10.1007/s10439-022-02941-0 · Cited by 13
Caravaggi, P., Assirelli, E., Ensini, A., Ortolani, M., Mariani, E., Leardini, A., Neri, S., & Belvedere, C. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.634327 · Cited by 12
Anijs, T., Eemers, S., Minoda, Y., Wolfson, D., Verdonschot, N. J. J., & Janssen, D. W. (2021) · Journal of Biomedical Materials Research Part B Applied Biomaterials · doi:10.1002/jbm.b.34957 · Cited by 12
Zhang, L., Liu, G., Yan, Y., Han, B., Li, H., Ma, J., & Wang, X. (2022) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2022.2101889 · Cited by 12
Schiebl, J., Tröster, M., Idoudi, W., Gneiting, E., Spies, L., Maufroy, C., Schneider, U., & Bauernhansl, T. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192315533 · Cited by 12
Normalized patellofemoral joint reaction force is greater in individuals with patellofemoral pain
Thomeer, L. T., Sheehan, F. T., & Jackson, J. N. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.06.024 · Cited by 12
Koh, Y., Son, J., Kwon, O., Kwon, S. K., & Kang, K. (2018) · Bio-Medical Materials and Engineering · doi:10.3233/bme-180998 · Cited by 12
Verlaan, L., Boekesteijn, R. J., Oomen, P., Liu, W.-Y., Peters, M. J. M., Emans, P. J., van Rhijn, L. W., & Meijer, K. (2019) · Gait & Posture · doi:10.1016/j.gaitpost.2019.07.192 · Cited by 12
Hossain, N. A., Yamomo, G. G., Willing, R. T., & Towfighian, S. (2021) · Journal of Biomechanical Engineering · doi:10.1115/1.4051220 · Cited by 12
Manda, K., & Eriksson, A. (2013) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-013-0521-0 · Cited by 12
Acute Effects of Walking on the Deformation of Femoral Articular Cartilage in Older Adults
Ho, K., McClaren, J., & Sudweeks, S. (2018) · Journal of Geriatric Physical Therapy · doi:10.1519/jpt.0000000000000185 · Cited by 11
Wang, H., Tao, M., Shi, Q., He, K., & Cheng, C. (2022) · Bioengineering · doi:10.3390/bioengineering9100507 · Cited by 11
Perrone, M., Guidetti, M., Galli, M., Nho, S. J., Wimmer, M. A., & Malloy, P. J. (2023) · Journal of Orthopaedic Research® · doi:10.1002/jor.25744 · Cited by 10
Alteration in ACL loading after total and partial medial meniscectomy
Uzuner, S., & Li, L. (2024) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-024-07201-x · Cited by 11
Accurate internal–external rotation measurement in total knee prostheses: A magnetic solution
Arami, A., Miehlbradt, J., & Aminian, K. (2012) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2012.05.023 · Cited by 11
Oh, J., Kuenze, C. M., Signorile, J. F., Andersen, M. S., Letter, M. I., Best, T. M., Ripic, Z., Emerson, C. P., & Eltoukhy, M. A. (2020) · Gait & Posture · doi:10.1016/j.gaitpost.2020.12.025 · Cited by 10
Lampen, N., Su, H., Chan, D. D., & Yan, P. (2022) · Journal of Orthopaedic Research® · doi:10.1002/jor.25338 · Cited by 11
Osteochondral junction leakage and cartilage joint lubrication
Li, Q., Miramini, S., Smith, D. W., Gardiner, B. S., & Zhang, L. (2023) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2023.107353 · Cited by 11
Wan, Q., Zhang, A., Liu, Y., Chen, H., Zhang, J., Xue, H., Han, Q., & Wang, J. (2023) · Heliyon · doi:10.1016/j.heliyon.2023.e13819 · Cited by 11
The effects of geometric uncertainties on computational modelling of knee biomechanics
Meng, Q., Fisher, J., & Wilcox, R. K. (2017) · Royal Society Open Science · doi:10.1098/rsos.170670 · Cited by 11
Robinson, D. L., Jiang, H., Song, Q., Yates, C. J., Lee, P. V. S., & Wark, J. D. (2018) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-018-1079-7 · Cited by 11
Koh, Y., Lee, J.-A., Chung, P. K., & Kang, K. (2018) · Artificial Organs · doi:10.1111/aor.13382 · Cited by 11
Kang, K., Kwon, S. K., Kwon, O., Lee, J., & Koh, Y. (2018) · The Knee · doi:10.1016/j.knee.2018.11.017 · Cited by 11
Ali, A. A., Clary, C. W., Smoger, L. M., Dennis, D. A., Fitzpatrick, C. K., Rullkoetter, P. J., & Laz, P. J. (2020) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-020-01295-7 · Cited by 11
Population-based effect of total knee arthroplasty alignment on simulated tibial bone remodeling
Anijs, T., Wolfson, D., Verdonschot, N. J. J., & Janssen, D. W. (2020) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2020.104014 · Cited by 11
Kwon, H. M., Lee, J., Koh, Y., Park, K. K., & Kang, K. (2020) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-020-02047-0 · Cited by 11
Wang, H., Zhang, M., & Cheng, C. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00173 · Cited by 11
Biehl, M., Damm, P., Trepczynski, A., Preiß, S., & Salzmann, G. M. (2021) · Journal of Experimental Orthopaedics · doi:10.1186/s40634-021-00324-3 · Cited by 11
Knee Joint Forces When Rising from Kneeling Positions
HIROKAWA, S., & FUKUNAGA, M. (2013) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.8.27 · Cited by 11
Yıldırım, G., Gopalakrishnan, A., Davignon, R., Parker, J. W., Chawla, H., & Pearle, A. D. (2016) · The Journal of Arthroplasty · doi:10.1016/j.arth.2016.02.034 · Cited by 11
Battery-Less Wireless Instrumented Knee Implant
Holmberg, J., Alexander, L., Rajamani, R., & Bechtold, J. E. (2013) · Journal of Medical Devices · doi:10.1115/1.4023412 · Cited by 11
Rizvi, S. H. A., Zaheer, M. U., & Chang, S. (2022) · Composites Science and Technology · doi:10.1016/j.compscitech.2022.109416 · Cited by 10
Gibbons, K. D., Malbouby, V., Alvarez, O., & Fitzpatrick, C. K. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.1059003 · Cited by 10
Design, Simulations and Tests of a Novel Force and Moments Sensor for Instrumented Knee Implants
Gasnier, P., Burlet, J.-Y., Rammouz, R., Aloui, S., Brulais, S., Nonglaton, G., Leconte, L., de Casson, F. B., Dardenne, G., & Stindel, É. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3289623 · Cited by 12
Lower-limb internal loading and potential consequences for fracture healing
Heyland, M., Deppe, D., Reisener, M., Damm, P., Taylor, W. R., Reinke, S., Duda, G. N., & Trepczynski, A. (2023) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2023.1284091 · Cited by 10
Febrer-Nafría, M., Dreyer, M. J., Maas, A., Taylor, W. R., Smith, C. R., & Nasab, S. H. H. (2023) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2023.111851 · Cited by 10
Hu, C., Lu, T., & Chen, S. (2013) · BioMedical Engineering OnLine · doi:10.1186/1475-925x-12-20 · Cited by 10
Mechanical testing of knee implants
Clary, C. W., & Maletsky, L. P. (2017) · Elsevier eBooks · doi:10.1016/b978-0-08-100286-5.00011-1 · Cited by 10
The development of simulator testing for total knee replacements
Maag, C., Amber, M., Cracaoanu, I., Wise, C., & Auger, D. D. (2021) · Biosurface and Biotribology · doi:10.1049/bsb2.12001 · Cited by 10
Yan, B., Huang, X., Xu, Y., & Zou, C. (2023) · Orthopaedic Surgery · doi:10.1111/os.13660 · Cited by 10
Vervaat, W., Bogen, B. E., & Moe‐Nilssen, R. (2020) · Physiotherapy Theory and Practice · doi:10.1080/09593985.2020.1723150 · Cited by 10
Dusfour, G., Maumus, M., Cañadas, P., Ambard, D., Jørgensen, C., Noël, D., & Floc’h, S. L. (2020) · Materials Science and Engineering C · doi:10.1016/j.msec.2020.110808 · Cited by 10
A Probabilistic Failure Risk Approach to The Problem of Articular Cartilage Lubrication
Liao, J., Smith, D. W., Miramini, S., Gardiner, B. S., & Zhang, L. (2021) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2021.106053 · Cited by 10
Jun, S.-K., Zhou, X., Ramsey, D. K., & Krovi, V. (2015) · Journal of Mechanisms and Robotics · doi:10.1115/1.4030653 · Cited by 10
Techniques to determine knee joint contact forces during squatting: A systematic review
Kothurkar, R., & Lekurwale, R. (2022) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1177/09544119221091609 · Cited by 9
Hashizume, T., Ishii, Y., Nakashima, Y., Okamoto, S., Iwamoto, Y., Okada, K., Takagi, K., Adachi, N., & Takahashi, M. K. (2023) · Journal of Medical Ultrasonics · doi:10.1007/s10396-023-01348-1 · Cited by 9
Metadata
- Authors
- Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- Berlin-Brandenburger Centrum für Regenerative Therapien (DE)
- Corresponding author
- Kutzner, I.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 43
- Issue
- 11
- Pages
- 2164-2173
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1972617433
- Cited by
- 798
- References
- 19
- Citations by year
- 2026: 55 · 2025: 48 · 2024: 42 · 2023: 38 · 2022: 66 · 2021: 49 · 2020: 52 · 2019: 70 · 2018: 65 · 2017: 56 · 2016: 49 · 2015: 49 · 2014: 51 · 2013: 50 · 2012: 28
- FWCI
- 36.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- knee joint loading, activities of daily living, in vivo measurement, shear force, stair climbing, walking, knee flexion
- MeSH terms
- Activities of Daily Living, Aged, Computer Simulation, Female, Humans, Knee Joint, Male, Middle Aged, Models, Biological, Stress, Mechanical, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review