The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Loading of the knee joint during activities of daily living measured in vivo in five subjects
Abstract
Detailed knowledge about loading of the knee joint is essential for preclinical testing of implants, validation of musculoskeletal models and biomechanical understanding of the knee joint. The contact forces and moments acting on the tibial component were therefore measured in 5 subjects in vivo by an instrumented knee implant during various activities of daily living. Average peak resultant forces, in percent of body weight, were highest during stair descending (346% BW), followed by stair ascending (316% BW), level walking (261% BW), one legged stance (259% BW), knee bending (253% BW), standing up (246% BW), sitting down (225% BW) and two legged stance (107% BW). Peak shear forces were about 10-20 times smaller than the axial force. Resultant forces acted almost vertically on the tibial plateau even during high flexion. Highest moments acted in the frontal plane with a typical peak to peak range -2.91% BWm (adduction moment) to 1.61% BWm (abduction moment) throughout all activities. Peak flexion/extension moments ranged between -0.44% BWm (extension moment) and 3.16% BWm (flexion moment). Peak external/internal torques lay between -1.1% BWm (internal torque) and 0.53% BWm (external torque). The knee joint is highly loaded during daily life. In general, resultant contact forces during dynamic activities were lower than the ones predicted by many mathematical models, but lay in a similar range as measured in vivo by others. Some of the observed load components were much higher than those currently applied when testing knee implants.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This loading condition represented a worst-case outcome for the ACL during walking (Kutzner et al., 2010).”
From The Femoral Tunnel Drilling Angle at 45° Coronal and 45° Sagittal Provided the Lowest Peak Stress and Strain on the Bone Tunnels and Anterior Cruciate Ligament Graft (2021) · cites this paper as Kutzner et al., 2010
Citations
Cites
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,062
The prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A. A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 500
Tibio‐femoral loading during human gait and stair climbing
Taylor, W. R., Heller, M. O. W., Bergmann, G., & Duda, G. N. (2003) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2003.09.003 · Cited by 377
Knee and hip kinetics during normal stair climbing
Costigan, P. A., Deluzio, K. J., & WYSS, U. P. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00201-6 · Cited by 325
Function of the knee joint in various activities.
Morrison, J. B. (1969) · PubMed · Cited by 318
Alignment of curves by dynamic time warping
Wang, K., & Gasser, T. (1997) · The Annals of Statistics · doi:10.1214/aos/1069362747 · Cited by 296
Mündermann, A., Dyrby, C. O., DʼLima, D. D., Colwell, C. W., & Andriacchi, T. P. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20655 · Cited by 250
Taylor, S. J. G., Walker, P. S., Perry, J. S., Cannon, S. R., & WOLEDGE, R. C. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90009-2 · Cited by 246
Tibial Forces Measured In Vivo After Total Knee Arthroplasty
DʼLima, D. D., Patil, S. S., Steklov, N., Slamin, J. E., & Colwell, C. W. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.07.011 · Cited by 232
Heinlein, B., Kutzner, I., Graichen, F., Bender, A., Rohlmann, A., Halder, A. M., Beier, A., & Bergmann, G. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.011 · Cited by 201
Cited by
Sorted by citations
Items 201–300 of 797
Vrancken, A. C. T., Eggermont, F., van Tienen, T. G., Hannink, G., Buma, P., Janssen, D. W., & Verdonschot, N. J. J. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-015-3632-6 · Cited by 29
Development of a statistical model of knee kinetics for applications in pre-clinical testing
Galloway, F., Worsley, P. R., Stokes, M. J., Nair, P. B., & Taylor, M. (2011) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2011.09.009 · Cited by 29
Schwiesau, J., Fritz, B., Kutzner, I., Bergmann, G., & Grupp, T. M. (2014) · BioMed Research International · doi:10.1155/2014/567374 · Cited by 29
Hajizadeh, M., Oskouei, A. H., Ghalichi, F., & Sole, G. (2016) · PM&R · doi:10.1016/j.pmrj.2016.01.014 · Cited by 29
Knee Implant Loosening Detection: A Vibration Analysis Investigation
Arami, A., Delaloye, J., Rouhani, H., Jolles, B. M., & Aminian, K. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1941-2 · Cited by 29
Shape and function of the diaphysis of the human tibia
Cristofolini, L., Angeli, E., Juszczyk, J., & Juszczyk, M. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.04.026 · Cited by 28
Kang, K., Kwon, O., Son, J., Suh, D., Kwon, S. K., & Koh, Y. (2018) · Australasian Physical & Engineering Sciences in Medicine · doi:10.1007/s13246-018-0630-2 · Cited by 28
In vivo implant forces acting on a vertebral body replacement during upper body flexion
Dreischarf, M., Albiol, L., Zander, T., Arshad, R., Graichen, F., Bergmann, G., Schmidt, H., & Rohlmann, A. (2015) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2015.01.007 · Cited by 28
Brandon, S. C. E., Brown, M., Clouthier, A. L., Campbell, A. R., Richards, J., & Deluzio, K. J. (2019) · The Knee · doi:10.1016/j.knee.2019.04.006 · Cited by 28
A new shoulder model with a biologically inspired glenohumeral joint
Quental, C., Folgado, J., Ambrósio, J., & Monteiro, J. (2016) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2016.06.012 · Cited by 27
Klets, O., Mononen, M. E., Liukkonen, M. K., Nevalainen, M. T., Nieminen, M. T., Saarakkala, S. S., & Korhonen, R. K. (2017) · Annals of Biomedical Engineering · doi:10.1007/s10439-017-1974-6 · Cited by 27
Grupp, T. M., Schilling, C., Schwiesau, J., Pfaff, A. M., Altermann, B., & Mihalko, W. M. (2019) · The Journal of Arthroplasty · doi:10.1016/j.arth.2019.09.019 · Cited by 27
Structure and Function of Articular Cartilage
Gahunia, H. K., & Pritzker, K. P. H. (2020) · Springer eBooks · doi:10.1007/978-1-4939-7587-7_1 · Cited by 29
Anteroposterior Knee Stability During Stair Descent
Borque, K. A., Gold, J. E., Incavo, S. J., Patel, R. M., Ismaily, S. K., & Noble, P. C. (2015) · The Journal of Arthroplasty · doi:10.1016/j.arth.2015.01.011 · Cited by 27
Kang, K., Koh, Y., Son, J., Kwon, O., & Park, K. K. (2018) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-018-5093-1 · Cited by 27
Metatarsal Loading During Gait—A Musculoskeletal Analysis
Al-Munajjed, A. A., Bischoff, J. E., Dharia, M. A., Telfer, S., Woodburn, J., & Carbes, S. (2015) · Journal of Biomechanical Engineering · doi:10.1115/1.4032413 · Cited by 26
Bolcos, P. O., Mononen, M. E., Tanaka, M. S., Yang, M., Suomalainen, J., Nissi, M. J., Töyräs, J., Ma, B., Li, X., & Korhonen, R. K. (2019) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2019.08.004 · Cited by 26
Samsami, S., Pätzold, R., Winkler, M., Herrmann, S., & Augat, P. (2020) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-020-03412-8 · Cited by 26
Micromotion and Migration of Cementless Tibial Trays Under Functional Loading Conditions
Han, S., Patel, R. V., Ismaily, S. K., Jones, H. L., Gold, J. E., & Noble, P. C. (2020) · The Journal of Arthroplasty · doi:10.1016/j.arth.2020.07.017 · Cited by 26
Serrancolí, G., Kinney, A. L., & Fregly, B. J. (2020) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2020.09.004 · Cited by 26
Nonoperative Treatment of Unicompartmental Arthritis
Bert, J. M., & Bert, T. M. (2013) · Clinics in Sports Medicine · doi:10.1016/j.csm.2013.08.002 · Cited by 27
Ardestani, M. M., Moazen, M., & Jin, Z. M. (2014) · Expert Systems with Applications · doi:10.1016/j.eswa.2014.06.034 · Cited by 26
Effects of resection thickness on mechanics of resurfaced patellae
Fitzpatrick, C. K., Kim, R. H., Ali, A. A., Smoger, L. M., & Rullkoetter, P. J. (2013) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.03.016 · Cited by 25
Medial knee joint loading during stair ambulation and walking while carrying loads
Hall, M., Boyer, E. R., Gillette, J. C., & Mirka, G. A. (2012) · Gait & Posture · doi:10.1016/j.gaitpost.2012.08.008 · Cited by 25
Kang, K., Koh, Y., Son, J., Kwon, O., Lee, J., & Kwon, S. K. (2017) · BioMed Research International · doi:10.1155/2017/4908639 · Cited by 25
Investigation of role of cartilage surface polymer brush border in lubrication of biological joints
Liao, J., Smith, D. W., Miramini, S., Gardiner, B. S., & Zhang, L. (2021) · Friction · doi:10.1007/s40544-020-0468-y · Cited by 25
Frigo, C., & Donno, L. (2021) · Applied Sciences · doi:10.3390/app11052356 · Cited by 25
Hodgkinson, T., Amado, I., O’Brien, F. J., & Kennedy, O. D. (2022) · APL Bioengineering · doi:10.1063/5.0068277 · Cited by 28
Marouane, H., Shirazi-Adl, A., & Adouni, M. (2013) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2013.795555 · Cited by 25
Thorhauer, E. D., & Tashman, S. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.07.002 · Cited by 25
Räsänen, L. P., Tanska, P., Mononen, M. E., Lammentausta, E., Zbýň, Š., Venäläinen, M. S., Szomolányi, P., van Donkelaar, C. C., Jurvelin, J. S., Trattnig, S., et al. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.09.011 · Cited by 25
An extended OpenSim knee model for analysis of strains of connective tissues
Marieswaran, M., Sikidar, A., Goel, A., Joshi, D., & Kalyanasundaram, D. (2018) · BioMedical Engineering OnLine · doi:10.1186/s12938-018-0474-8 · Cited by 25
Kang, K., Son, J., Kwon, S. K., Kwon, O., Park, J.-H., & Koh, Y. (2018) · Composite Structures · doi:10.1016/j.compstruct.2018.06.036 · Cited by 25
Yao, J., Wen, C., Cheung, J. T., Zhang, M., Hu, Y. S., Yan, C., Chiu, P., Lu, W. W., & Fan, Y. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-012-0517-4 · Cited by 25
Rothbauer, M., Reihs, E. I., Fischer, A., Windhager, R. H., Jenner, F., & Toegel, S. (2022) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2022.886360 · Cited by 24
Briem, K., & Ramsey, D. K. (2013) · Sports Medicine and Arthroscopy Review · doi:10.1097/jsa.0b013e31827562b5 · Cited by 24
Risk Factors for Knee Injury in Golf: A Systematic Review
Baker, M. L., Epari, D. R., Lorenzetti, S., Sayers, M. G. L., Boutellier, U., & Taylor, W. R. (2017) · Sports Medicine · doi:10.1007/s40279-017-0780-5 · Cited by 24
Loading of the hip and knee joints during whole body vibration training
Bergmann, G., Kutzner, I., Bender, A., Dymke, J., Trepczynski, A., Duda, G., Felsenberg, D., & Damm, P. (2018) · PLoS ONE · doi:10.1371/journal.pone.0207014 · Cited by 22
Instrumented knee joint implants: innovations and promising concepts
Torrão, J., dos Santos, M. P. S., & Ferreira, J. (2015) · Expert Review of Medical Devices · doi:10.1586/17434440.2015.1068114 · Cited by 24
Sensitivity analysis of human lower extremity joint moments due to changes in joint kinematics
Ardestani, M. M., Moazen, M., & Jin, Z. M. (2014) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2014.11.012 · Cited by 24
Forces acting on the anterior meniscotibial ligaments
Seitz, A. M., Kasisari, R., Claes, L., Ignatius, A. A., & Dürselen, L. (2011) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-011-1708-5 · Cited by 24
Horisberger, M., Fortuna, R., Leonard, T. R., Valderrábano, V., & Herzog, W. (2011) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2011.09.012 · Cited by 23
Lundberg, H. J., Knowlton, C. B., & Wimmer, M. A. (2013) · Journal of Biomechanical Engineering · doi:10.1115/1.4023388 · Cited by 23
van de Groes, S., de Waal-Malefijt, M., & Verdonschot, N. J. J. (2013) · The Knee · doi:10.1016/j.knee.2013.05.003 · Cited by 23
Damage in total knee replacements from mechanical overload
Zimmerman, W. F., Miller, M. A., Cleary, R. J., Izant, T. H., & Mann, K. A. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.05.014 · Cited by 23
Liu, C., Wang, Y., Li, Z., Li, J., Zhang, H., Fu, Y., & Zhang, K. (2018) · Journal of Orthopaedic Surgery and Research · doi:10.1186/s13018-018-0956-1 · Cited by 23
Keogh, J., Grigg, J., & Vertullo, C. J. (2017) · Orthopaedic Journal of Sports Medicine · doi:10.1177/2325967117694334 · Cited by 22
Changes in Knee Joint Mechanics After Medial Meniscectomy Determined With a Poromechanical Model
Uzuner, S., Li, L., Küçük, S., & Memişoğlu, K. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047343 · Cited by 22
Enclosed Electronic System for Force Measurements in Knee Implants
Forchelet, D., Simoncini, M., Arami, A., Bertsch, A., Meurville, E., Aminian, K., Peter Ryser, A., & Renaud, P. (2014) · Sensors · doi:10.3390/s140815009 · Cited by 22
Form follows function: a computational simulation exercise on bone shape forming and conservation.
Mittag, U., Kriechbaumer, A., Bartsch, M., & Rittweger, J. (2015) · PubMed Central · Cited by 22
Instrumented prosthesis for knee implants monitoring
Arami, A., Simoncini, M., Atasoy, O., Hasenkamp, W., Ali, S., Bertsch, A., Meurville, E., Tanner, S., Dejnabadi, H., Leclercq, V., et al. (2011) · IEEE International Conference on Automation Science and Engineering (CASE) · doi:10.1109/case.2011.6042490 · Cited by 22
Kaze, A. D., Maas, S., Arnoux, P., Wolf, C., & Pape, D. (2017) · BioMedical Engineering OnLine · doi:10.1186/s12938-017-0428-6 · Cited by 22
Sectioning of the Anterior Intermeniscal Ligament Changes Knee Loading Mechanics
Ollivier, M. P., Falguières, J., Pithioux, M., Boisrenoult, P., Beaufils, P., & Pujol, N. (2018) · Arthroscopy The Journal of Arthroscopic and Related Surgery · doi:10.1016/j.arthro.2018.03.007 · Cited by 22
Kang, K., Koh, Y., Son, J., Kwon, O., Lee, J., & Kwon, S. K. (2018) · BioMed Research International · doi:10.1155/2018/5139074 · Cited by 22
Fitzpatrick, C. K., Komistek, R. D., & Rullkoetter, P. J. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.04.024 · Cited by 21
Schellenberg, F., Taylor, W. R., & Lorenzetti, S. (2017) · BMC Sports Science Medicine and Rehabilitation · doi:10.1186/s13102-017-0077-x · Cited by 21
Recent developments and advancements in knee implants materials, manufacturing: A review
Pande, S., & Dhatrak, P. N. (2021) · Materials Today Proceedings · doi:10.1016/j.matpr.2020.12.465 · Cited by 21
Zhang, X., Yuan, S., Wang, J., Liao, B., & Liang, D. (2021) · BMC Musculoskeletal Disorders · doi:10.1186/s12891-021-04187-8 · Cited by 21
Filip, A. C., Cuculici, Ș. A., Cristea, Ș., Filip, V., Negrea, A. D., Mihai, S., & Panţu, C. (2022) · Medicina · doi:10.3390/medicina58050634 · Cited by 21
Knee kinetics and kinematics: What are the effects of TKA malconfigurations?
Pianigiani, S., Labey, L., Pascale, W., & Innocenti, B. (2015) · Knee Surgery Sports Traumatology Arthroscopy · doi:10.1007/s00167-015-3514-y · Cited by 21
Saikko, V. O. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2014.04.039 · Cited by 21
Pauchard, Y., Ivanov, T. G., McErlain, D. D., Milner, J. S., Giffin, J. R., Birmingham, T. B., & Holdsworth, D. W. (2014) · Journal of Biomechanical Engineering · doi:10.1115/1.4028966 · Cited by 21
Simultaneous estimation of ground reaction force and knee contact force during walking and squatting
Jung, Y., Koo, Y.-J., & Koo, S. (2017) · International Journal of Precision Engineering and Manufacturing · doi:10.1007/s12541-017-0148-7 · Cited by 21
Moewis, P., Checa, S., Kutzner, I., Hommel, H., & Duda, G. N. (2018) · PLoS ONE · doi:10.1371/journal.pone.0192225 · Cited by 21
Parametric study of a triboelectric transducer in total knee replacement application
Ibrahim, A. I., Yamomo, G. G., Willing, R. T., & Towfighian, S. (2020) · Journal of Intelligent Material Systems and Structures · doi:10.1177/1045389x20948581 · Cited by 21
Lee, J., Koh, Y., Kim, P. S., Kang, K. W., Kwak, Y. H., & Kang, K. (2020) · Bone and Joint Research · doi:10.1302/2046-3758.99.bjr-2020-0128.r1 · Cited by 21
Cheng, R., Wang, H., Jiang, Z., Dimitriou, D., Cheng, C.-K., & Tsai, T.-Y. (2021) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2021.797389 · Cited by 20
“9 Nm, 1% body weight) during normal human walking (Kutzner et al., 2010;Wang et al., 2020a;Wang et al., 2020b)were applied to the ACLR model using different tunnel angles at a joint flexion angle of 20° (Wang et al.”
BackgroundMethodInfluentialYao, J., Wen, C. Y., Zhang, M., Cheung, J. T.-M., Yan, C., Chiu, K.-Y., Lu, W. W., & Fan, Y. (2014) · International Orthopaedics · doi:10.1007/s00264-014-2290-5 · Cited by 20
Jahn, J., Ehlen, Q. T., & Huang, C.-Y. C. (2024) · Bioengineering · doi:10.3390/bioengineering11020110 · Cited by 21
McLain, B. J., Lee, D., Mulrine, S. C., & Young, A. J. (2022) · Annals of Biomedical Engineering · doi:10.1007/s10439-022-02950-z · Cited by 20
Esrafilian, A., Stenroth, L., Mononen, M. E., Vartiainen, P., Tanska, P., Karjalainen, P. A., Suomalainen, J., Arokoski, J. P., Saxby, D. J., Lloyd, D. G., et al. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3159685 · Cited by 20
Load application for the contact mechanics analysis and wear prediction of total knee replacement
Zhang, J., Chen, Z., Wang, L., Li, D., & Jin, Z. M. (2017) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411917693880 · Cited by 20
Myller, K. A. H., Korhonen, R. K., Töyräs, J., Salo, J., Jurvelin, J. S., & Venäläinen, M. S. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24273 · Cited by 20
Meniscal Replacement With a Silk Fibroin Scaffold Reduces Contact Stresses in the Human Knee
Stein, S., Höse, S., Warnecke, D., Gentilini, C., Skaer, N., Walker, R. W., Kessler, O., Ignatius, A. A., & Dürselen, L. (2019) · Journal of Orthopaedic Research® · doi:10.1002/jor.24437 · Cited by 20
Rasnick, R. J., Standifird, T. W., Reinbolt, J. A., Cates, H. E., & Zhang, S. (2016) · PLoS ONE · doi:10.1371/journal.pone.0156282 · Cited by 21
Effects of Proud Large Osteochondral Plugs on Contact Forces and Knee Kinematics: A Robotic Study
Du, P. Z., Markolf, K. L., Boguszewski, D. V., Yamaguchi, K. T., Lama, C. J., McAllister, D. R., & Jones, K. J. (2018) · The American Journal of Sports Medicine · doi:10.1177/0363546518770415 · Cited by 20
Trepczynski, A., Kutzner, I., Schütz, P., Dymke, J., List, R., von Roth, P., Moewis, P., Bergmann, G., Taylor, W. R., & Duda, G. N. (2019) · Scientific Reports · doi:10.1038/s41598-018-37189-z · Cited by 20
Self-Powered Load Sensing Circuitry for Total Knee Replacement
Jain, M., Hossain, N. A., Towfighian, S., Willing, R. T., Stanaćević, M., & Salman, E. (2021) · IEEE Sensors Journal · doi:10.1109/jsen.2021.3110241 · Cited by 19
Cvečka, J., Vajda, M., Novotná, A., Löfler, S., Hamar, D., & Krčmár, M. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20043172 · Cited by 19
Ardestani, M. M., Moazen, M., Maniei, E., & Jin, Z. M. (2015) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2015.01.008 · Cited by 19
Soldier-relevant body borne loads increase knee joint contact force during a run-to-stop maneuver
Ramsay, J. W., Hancock, C. L., O’Donovan, M. P., & Brown, T. N. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.10.022 · Cited by 19
Räsänen, L. P., Tanska, P., Zbýň, Š., van Donkelaar, C. C., Trattnig, S., Nieminen, M. T., & Korhonen, R. K. (2017) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2017.06.041 · Cited by 19
Kang, K., Son, J., Kwon, S. K., Kwon, O., & Koh, Y. (2018) · Bio-Medical Materials and Engineering · doi:10.3233/bme-181015 · Cited by 19
Kang, K., Park, J.-H., Koh, Y., Shin, J., & Park, K. K. (2019) · Bio-Medical Materials and Engineering · doi:10.3233/bme-191039 · Cited by 19
Mainardi, A., Börsch, A., Occhetta, P., Ivánek, R., Ehrbar, M., Krattiger, L. A., Oertle, P., Loparić, M., Martín, I., Rasponi, M., et al. (2025) · Advanced Healthcare Materials · doi:10.1002/adhm.202501588 · Cited by 18
Bauer, L., Woiczinski, M., Thorwächter, C., Müller, P. E., Holzapfel, B. M., Niethammer, T. R., & Simon, J. (2022) · Archives of Orthopaedic and Trauma Surgery · doi:10.1007/s00402-022-04661-5 · Cited by 18
Tennant, L. M., Chong, H., & Acker, S. M. (2017) · Ergonomics · doi:10.1080/00140139.2017.1411529 · Cited by 18
Kang, K., Kwon, S. K., Son, J., Kwon, O., Lee, J., & Koh, Y. (2018) · The Knee · doi:10.1016/j.knee.2018.06.011 · Cited by 18
Park, K. K., Koh, Y., Park, K.-M., Park, J.-H., & Kang, K. (2019) · Bio-Medical Materials and Engineering · doi:10.3233/bme-191042 · Cited by 18
The influence of task complexity on knee joint kinetics following ACL reconstruction
Schroeder, M. J., Krishnan, C., & Dhaher, Y. Y. (2015) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2015.06.003 · Cited by 18
Comparison of ISO Standard and TKR patient axial force profiles during the stance phase of gait
Lundberg, H. J., Ngai, V., & Wimmer, M. A. (2011) · Proceedings of the Institution of Mechanical Engineers Part H Journal of Engineering in Medicine · doi:10.1177/0954411911431650 · Cited by 18
Arami, A., Vallet, A., & Aminian, K. (2013) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2013.2259489 · Cited by 18
Simulation of Soft Tissue Loading from Observed Movement Dynamics
Brandon, S. C. E., Smith, C. R., & Thelen, D. G. (2017) · Springer eBooks · doi:10.1007/978-3-319-30808-1_172-1 · Cited by 18
Wireless electronic-free mechanical metamaterial implants
Luo, J., Lu, W., Jiao, P., Jang, D., Barri, K., Wang, J., Meng, W., Kumar, R. P., Agarwal, N., Hamilton, D. K., et al. (2025) · Materials Today · doi:10.1016/j.mattod.2024.12.018 · Cited by 17
Liu, S., Amiri, P., McGregor, A. H., & Bull, A. M. J. (2023) · Annals of Biomedical Engineering · doi:10.1007/s10439-023-03289-9 · Cited by 17
Gibert, S., Kowaleski, M. P., Matthys, R., Nützi, R., Serck, B., & Boudrieau, R. J. (2015) · Veterinary and Comparative Orthopaedics and Traumatology · doi:10.3415/vcot-15-07-0115 · Cited by 17
Cartilage loss patterns within femorotibial contact regions during deep knee bend
Johnson, J. M., & Mahfouz, M. R. (2016) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2016.04.011 · Cited by 17
Rullkoetter, P. J., Fitzpatrick, C. K., & Clary, C. W. (2016) · Journal of the American Academy of Orthopaedic Surgeons · doi:10.5435/jaaos-d-16-00640 · Cited by 17
Karpiński, R., Jaworski, Ł. M., Jonak, J., & Krakowski, P. (2019) · MATEC Web of Conferences · doi:10.1051/matecconf/201925207007 · Cited by 17
Statistical Modeling of Lower Limb Kinetics During Deep Squat and Forward Lunge
Roeck, J. D., Houcke, J. V., Almeida, D., Galibarov, P. E., Roeck, L. D., & Audenaert, E. A. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00233 · Cited by 16
Metadata
- Authors
- Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- Berlin-Brandenburger Centrum für Regenerative Therapien (DE)
- Corresponding author
- Kutzner, I.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 43
- Issue
- 11
- Pages
- 2164-2173
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1972617433
- Cited by
- 798
- References
- 19
- Citations by year
- 2026: 55 · 2025: 48 · 2024: 42 · 2023: 38 · 2022: 66 · 2021: 49 · 2020: 52 · 2019: 70 · 2018: 65 · 2017: 56 · 2016: 49 · 2015: 49 · 2014: 51 · 2013: 50 · 2012: 28
- FWCI
- 36.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- knee joint loading, activities of daily living, in vivo measurement, shear force, stair climbing, walking, knee flexion
- MeSH terms
- Activities of Daily Living, Aged, Computer Simulation, Female, Humans, Knee Joint, Male, Middle Aged, Models, Biological, Stress, Mechanical, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review