Loading of the knee joint during activities of daily living measured in vivo in five subjects
Abstract
Detailed knowledge about loading of the knee joint is essential for preclinical testing of implants, validation of musculoskeletal models and biomechanical understanding of the knee joint. The contact forces and moments acting on the tibial component were therefore measured in 5 subjects in vivo by an instrumented knee implant during various activities of daily living. Average peak resultant forces, in percent of body weight, were highest during stair descending (346% BW), followed by stair ascending (316% BW), level walking (261% BW), one legged stance (259% BW), knee bending (253% BW), standing up (246% BW), sitting down (225% BW) and two legged stance (107% BW). Peak shear forces were about 10-20 times smaller than the axial force. Resultant forces acted almost vertically on the tibial plateau even during high flexion. Highest moments acted in the frontal plane with a typical peak to peak range -2.91% BWm (adduction moment) to 1.61% BWm (abduction moment) throughout all activities. Peak flexion/extension moments ranged between -0.44% BWm (extension moment) and 3.16% BWm (flexion moment). Peak external/internal torques lay between -1.1% BWm (internal torque) and 0.53% BWm (external torque). The knee joint is highly loaded during daily life. In general, resultant contact forces during dynamic activities were lower than the ones predicted by many mathematical models, but lay in a similar range as measured in vivo by others. Some of the observed load components were much higher than those currently applied when testing knee implants.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This loading condition represented a worst-case outcome for the ACL during walking (Kutzner et al., 2010).”
From The Femoral Tunnel Drilling Angle at 45° Coronal and 45° Sagittal Provided the Lowest Peak Stress and Strain on the Bone Tunnels and Anterior Cruciate Ligament Graft (2021) · cites this paper as Kutzner et al., 2010
Citations
Cites
The mechanics of the knee joint in relation to normal walking
Morrison, J. B. (1970) · Journal of Biomechanics · doi:10.1016/0021-9290(70)90050-3 · Cited by 1,062
The prediction of muscular load sharing and joint forces in the lower extremities during walking
Seireg, A. A., & Arvikar, R. J. (1975) · Journal of Biomechanics · doi:10.1016/0021-9290(75)90089-5 · Cited by 500
Tibio‐femoral loading during human gait and stair climbing
Taylor, W. R., Heller, M. O. W., Bergmann, G., & Duda, G. N. (2003) · Journal of Orthopaedic Research® · doi:10.1016/j.orthres.2003.09.003 · Cited by 377
Knee and hip kinetics during normal stair climbing
Costigan, P. A., Deluzio, K. J., & WYSS, U. P. (2002) · Gait & Posture · doi:10.1016/s0966-6362(01)00201-6 · Cited by 325
Function of the knee joint in various activities.
Morrison, J. B. (1969) · PubMed · Cited by 318
Alignment of curves by dynamic time warping
Wang, K., & Gasser, T. (1997) · The Annals of Statistics · doi:10.1214/aos/1069362747 · Cited by 296
Mündermann, A., Dyrby, C. O., DʼLima, D. D., Colwell, C. W., & Andriacchi, T. P. (2008) · Journal of Orthopaedic Research® · doi:10.1002/jor.20655 · Cited by 250
Taylor, S. J. G., Walker, P. S., Perry, J. S., Cannon, S. R., & WOLEDGE, R. C. (1998) · The Journal of Arthroplasty · doi:10.1016/s0883-5403(98)90009-2 · Cited by 246
Tibial Forces Measured In Vivo After Total Knee Arthroplasty
DʼLima, D. D., Patil, S. S., Steklov, N., Slamin, J. E., & Colwell, C. W. (2006) · The Journal of Arthroplasty · doi:10.1016/j.arth.2005.07.011 · Cited by 232
Heinlein, B., Kutzner, I., Graichen, F., Bender, A., Rohlmann, A., Halder, A. M., Beier, A., & Bergmann, G. (2009) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2009.01.011 · Cited by 201
Cited by
Sorted by citations
Items 601–700 of 797
Ti-6Al-4V Fatigue Strength After Shot Peening: The Role of a Corrosive Environment
Sonntag, R., Reinders, J., Gibmeier, J., Jaeger, S., & Kretzer, J. P. (2013) · ASTM International eBooks · doi:10.1520/stp155920120151 · Cited by 2
Zhu, L., Garon, M., Quenneville, E., Buschmann, M. D., & Savard, P. (2016) · Gait & Posture · doi:10.1016/j.gaitpost.2016.10.011 · Cited by 2
Usman, U., & Huang, S. (2018) · Defect and diffusion forum/Diffusion and defect data, solid state data. Part A, Defect and diffusion forum · doi:10.4028/www.scientific.net/ddf.382.181 · Cited by 2
Current misjudgments and future trends in rehabilitation after knee injuries (Part 1)
Freiwald, J., Hoppe, M. W., Javanmardi, S., Hotfiel, T., Engelhardt, M., Grim, C., & Baumgart, C. (2020) · Sports Orthopaedics and Traumatology · doi:10.1016/j.orthtr.2020.07.008 · Cited by 2
Chong, H. (2016) · UWSpace (University of Waterloo) · Cited by 2
A study of a Gough-Stewart platform-based manipulator for applications in biomechanical testing.
Ding, B. (2014) · Adelaide Research & Scholarship (AR&S) (University of Adelaide) · Cited by 2
Finite Element Simulations of Biphasic Articular Cartilages With Localized Metal Implants
Manda, K. (2010) · KTH Publication Database DiVA (KTH Royal Institute of Technology) · Cited by 2
COMPUTATIONAL MODELLING OF MECHANICAL BEHAVIOR OF BIOLOGICAL TISSUES FOR BIOMEDICAL APPLICATIONS
Li, S., Liu, Y., Du, J., Zeybek, B., Zani, L., Lewis, M. P., & Silberschmidt, V. V. (2016) · VII European Congress on Computational Methods in Applied Sciences and Engineering · doi:10.7712/100016.1932.7715 · Cited by 1
Yamagata, M., Tateuchi, H., Asayama, A., & Ichihashi, N. (2024) · Gait & Posture · doi:10.1016/j.gaitpost.2024.05.023 · Cited by 1
Donno, L., Dubbini, C., & Frigo, C. (2025) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2025.106526 · Cited by 1
Tibial tray stability in three cementless total knee arthroplasty systems
Mueller, J. K. P., Lawrie, C. M., Parduhn, C., Bischoff, J. E., Siggelkow, E., Trischler, C., & Bandi, M. (2025) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2025.106652 · Cited by 1
Snyder, S. J., Fakhar, M., Miller, R. H., Bera, A., & Shim, J. K. (2025) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2025.112921 · Cited by 3
Hard-Stop Synthesis for Multi-Degrees-of-Freedom Compliant Mechanisms
Chen, D., Pomeroy, A. W., Peterson, B. T., Flanagan, W., Lim, H. K., Stavrakis, A. I., SooHoo, N. F., Hopkins, J. B., & Clites, T. R. (2025) · Journal of Mechanical Design · doi:10.1115/1.4069691 · Cited by 1
Xu, Y., Carman, L., Besier, T. F., & Choisne, J. (2025) · Biomechanics and Modeling in Mechanobiology · doi:10.1007/s10237-025-02016-8 · Cited by 1
Lee, D. H., Kwak, D., Kim, Y. D., Cho, N., & Koh, I. J. (2025) · Journal of Clinical Medicine · doi:10.3390/jcm14207384 · Cited by 1
Wearne, L. S., Dejea, H., Pierantoni, M., & Isaksson, H. (2026) · Materialia · doi:10.1016/j.mtla.2026.102770 · Cited by 1
Humanoid Locomotion with Roller Screw-Driven Knee Joints: Design, Control, and Deployment
Lin, Y., Xia, T., Wang, M., Zhang, Z., Lu, H., Ding, T., Zhang, Y., Zhao, X., & Tao, B. (2025) · Lecture notes in computer science · doi:10.1007/978-981-95-2098-5_42 · Cited by 1
Zhou, J., Liu, L., Zhi, P., Dong, Y., Liu, Z., & Fan, Y. (2025) · Bioengineering · doi:10.3390/bioengineering12111226 · Cited by 1
Lee, D. H., Kwak, D., Kim, Y. D., Lee, S. H., Cho, N., & Koh, I. J. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15041405 · Cited by 1
Guo, H., Ding, Q., Miramini, S., & Zhang, L. (2026) · European Journal of Applied Physiology · doi:10.1007/s00421-026-06173-1 · Cited by 1
Gschoßmann, L., Schedel, V., Süß, F., Weber, M., Pfingsten, A., & Dendorfer, S. (2026) · Technology and Health Care · doi:10.1177/09287329251413413 · Cited by 1
Three-Dimensional Kinematic Gait Analysis in Pediatric Patients With an ACL-Deficient Knee
Manitiu, A., Mehrpouyan, S., Mazy, D., Bayol, A., Delestre, C., Hagemeister, N., & Nault, M. (2026) · Orthopaedic Journal of Sports Medicine · doi:10.1177/23259671261441267 · Cited by 1
TRIBOLOGICAL BEHAVIOR OF 3D-PRINTED TITANIUM ALLOYS FOR MEDICAL IMPLANT APPLICATIONS
Ankur, K., Lal, R., & Singh, R. (2026) · Surface Review and Letters · doi:10.1142/s0218625x26300042 · Cited by 1
In vivo knee joint friction after total knee arthroplasty is highly dynamic and phase-dependent
Zierke, J. N., Moewis, P., Ehrig, R. M., Taylor, W. R., Trepczynski, A., Duda, G. N., & Damm, P. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2026.1885711 · Cited by 1
Stańczak, M., Kacprzak, B., & Hagner-Derengowska, M. (2026) · International Journal of Molecular Sciences · doi:10.3390/ijms27167462 · Cited by 2
Gramada, M., Baroudi, M., & Forthomme, J. (2011) · Cited by 1
ARE TIBIOFEMORAL COMPRESSIVE LOADS TRANSFERRED ONLY VIA CONTACT MECHANISMS?
Hakkak, F., Rostami, M., & Parnianpour, M. (2011) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519412004971 · Cited by 1
Biomechanik des endoprothetisch versorgten Kniegelenks
Mittelmeier, W., Souffrant, R., Kluess, D., Bergschmidt, P., & Bader, R. (2010) · Springer eBooks · doi:10.1007/978-3-642-12889-9_6 · Cited by 1
FUKUNAGA, M., MORIMOTO, K., Kajiwara, T., Ito, K., & Nagamine, R. (2017) · Journal of Biomechanical Science and Engineering · doi:10.1299/jbse.17-00247 · Cited by 1
The Phan-Thien and Tanner Model Applied to the Lubrication of Knee Prostheses
Weiss, B. A., Bou‐Saïd, B., Ubal, S., & Paolo, J. D. (2019) · Journal of Biomechanical Engineering · doi:10.1115/1.4043032 · Cited by 1
Liu, X., Huang, H., Ren, S., Ao, Y., & Rong, Q. (2019) · Computational methods in applied sciences · doi:10.1007/978-3-030-23132-3_2 · Cited by 1
KARIMI, M. T., HOSSEINI, S. I., & Bazargan-Lari, Y. (2021) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519421500226 · Cited by 1
Loading of the Knee Joint After Total Knee Arthroplasty
Moewis, P., Trepczynski, A., Bender, A., Duda, G. N., & Damm, P. (2022) · Springer eBooks · doi:10.1007/978-3-030-58178-7_4 · Cited by 1
Grupp, T. M., Schilling, C., Fritz, B., Reyna, A. L. P., Rusch, S., Taunt, C. J., & Mihalko, W. M. (2022) · The Journal of Arthroplasty · doi:10.1016/j.arth.2022.05.021 · Cited by 1
Biomechanics of human and artificial joints
MURAKAMI, T. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-823669-7.00008-9 · Cited by 1
Stewart, K. M., Klute, G. K., & Neptune, R. R. (2024) · Journal of Biomechanical Engineering · doi:10.1115/1.4065045 · Cited by 2
Biomechanische In-vitro-Testmethoden am Kniegelenk
Deichsel, A., Günther, D., Ackermann, J., Münch, L. N., Mathis, D. T., Schüttler, K. F., Wafaisade, A., Laky, B., Eggeling, L., & Herbst, E. (2024) · Arthroskopie · doi:10.1007/s00142-024-00712-8 · Cited by 1
Maldonado, A. A. E., Dolovich, A. T., Johnston, J. D., & McWalter, E. J. (2024) · Journal of Biomechanical Engineering · doi:10.1115/1.4066957 · Cited by 1
Phombut, C., Rooppakhun, S., Chaiyasit, K., & Bhakdisongkhram, G. (2024) · International Conference on Biomedical Engineering and Applications (ICBEA) · doi:10.1109/icbea62825.2024.00025 · Cited by 1
Behnam, Y. A., Krishnan, A. A., List, R., & Clary, C. W. (2024) · Bioengineering · doi:10.3390/bioengineering11111108 · Cited by 1
Eltlhawy, B., Fouda, N., & Eldesouky, I. (2024) · Novel Intelligent and Leading Emerging Sciences Conference (NILES) · doi:10.1109/niles63360.2024.10753167 · Cited by 1
Dahl, A. C. E., & Thompson, M. S. (2011) · Elsevier eBooks · doi:10.1016/b978-0-08-088504-9.00419-0 · Cited by 3
Sonntag, R., Reinders, J., & Kretzer, J. P. (2015) · IMPERIAL COLLEGE PRESS eBooks · doi:10.1142/9781783267170_0001 · Cited by 1
Toward Predicting the Performance of Joint Arthroplasty
Clare K. Fitzpatrick, M. H. (2015) · CRC Press eBooks · doi:10.1201/b18320-6 · Cited by 1
Effect of Average Conformity on Contact Stresses in Total Knee Replacement: Finite Element Analysis
Usman, U., & Huang, S. (2017) · MATEC Web of Conferences · doi:10.1051/matecconf/201710813006 · Cited by 1
Computational Musculoskeletal Biomechanics of the Knee Joint
Marouane, H., Shirazi-Adl, A., & Sharifi, M. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816390-0.00009-1 · Cited by 1
Walker, P. S. (2020) · Springer eBooks · doi:10.1007/978-3-030-38171-4_12 · Cited by 1
Kwak, Y. H., Hong, H.-T., Koh, Y., & Kang, K. (2020) · Applied Sciences · doi:10.3390/app10186487 · Cited by 1
Toe-out gait decreases knee load during stair descent in healthy individuals
Tsukagoshi, R., Honda, R., Senoo, H., Goto, M., Hashimoto, Y., & Yamanaka, A. (2021) · Journal of Cartilage & Joint Preservation · doi:10.1016/j.jcjp.2021.100002 · Cited by 1
Total Knee Arthroplasty for Fracture Treatment
Becker, R. (2022) · Springer eBooks · doi:10.1007/978-3-030-58178-7_46 · Cited by 1
Estimation of Tibiofemoral Joint Contact Forces Using Foot Loads during Continuous Passive Motions
Yang, Y., Huang, H., Guo, J., Yu, F., & Yao, Y. (2022) · Sensors · doi:10.3390/s22134947 · Cited by 1
Biomechanical Study on Injury and Treatment of Human Knee Joint
Yao, J., Yang, B., & Fan, Y. (2022) · Springer eBooks · doi:10.1007/978-981-16-4269-2_9 · Cited by 1
Computational stability of human musculoskeletal systems
Ghezelbash, F., Shirazi-Adl, A., Sharifi, M., Arjmand, N., & Bazrgari, B. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-823913-1.00025-7 · Cited by 1
Visser, J. (2015) · Utrecht University Repository (Utrecht University) · Cited by 1
Predicting Risk Factors of Non-Contact Anterior Cruciate Ligament Injuries during Single-Leg Landing
Nicholas, A. (2015) · uO Research (University of Ottawa) · doi:10.20381/ruor-2752 · Cited by 1
AN UPDATED TELEMETRY SYSTEM FOR RELIABLE POWERING IN VIVO COUPLED TO A TABLET COMPUTER
Ouellette, J. L. (2013) · UA Campus Repository (The University of Arizona) · Cited by 1
Potvin, B. M. (2016) · uO Research (University of Ottawa) · doi:10.20381/ruor-5828 · Cited by 1
McGillivary, T. L. (2015) · UWSpace (University of Waterloo) · Cited by 1
WIRELESS IMPLANTABLE MAGNETOELASTIC SENSORS AND ACTUATORS FOR BIOMEDICAL APPLICATIONS
DeRouin, A. J. (2016) · doi:10.37099/mtu.dc.etdr/233 · Cited by 1
Saxby, D. J. (2016) · Griffith Research Online · doi:10.25904/1912/1845 · Cited by 1
Fitzwater, F. G. (2014) · KU ScholarWorks (The University of Kansas)
Denney, L. (2014) · KU ScholarWorks (The University of Kansas)
Strategies Utilized during a Novel Rotary Task in Total Knee Replacement Subjects
Ferris, L. A. (2014) · KU ScholarWorks (The University of Kansas)
Battery-less wireless instrumented tibial tray.
Holmberg, J. (2011) · University of Minnesota Digital Conservancy (University of Minnesota)
Skeletal age estimation and the epiphyseal scar : challenging the status quo
Davies, C. M. (2013)
Henderson, C. E. (2024) · Library, Museums and Press - UDSpace (University of Delaware) · doi:10.58088/szph-4r93
Jääskeläinen, H. E., & Monto, J. (2011) · Jyväskylä University Digital Archive (University of Jyväskylä)
Yeakle, C. (2011) · OhioLink ETD Center (Ohio Library and Information Network)
Musculoskeletal analysis of people with stroke practicing Sit-to-Stand motion using a walker
Sheen, D.-P., Lee, K., Ko, B.-W., & Song, W.-K. (2014) · International Convention on Rehabilitation Engineering & Assistive Technology
Die anterioren meniskotibialen Ligamente: Kräfte unter verschiedenen Lastsituationen
Seitz, A. M., Kasisari, R., Lubomierski, A., Ignatius, A. A., & Dürselen, L. (2012) · Der Orthopäde
Die anterioren meniskotibialen Ligamente
Seitz, A. M., Kasisari, R., Lubomierski, A., Ignatius, A. A., & Dürselen, L. (2012) · Der Orthopäde · doi:10.1007/s00132-011-1856-9
Pierrat, B., Navarro, L., & Ea, L. (2013)
High flexion kinematics and kinetics for the improvement of artificial knee joints
Acker, S. M. (2010) · QSpace (Queen's University Library)
Evaluation and characterization of knee joint instability in ACL deficient patients
der Ingenieurwissenschaften, D. (2013)
Equivariant Functional Shape Analysis in SO(3) with Applications to Gait Analysis
Telschow, F. J. E. (2016) · doi:10.53846/goediss-5959
Alexander, N., & Schwameder, H. (2017) · Sportphysio · doi:10.1055/s-0042-120902
da Ponte, T. M., & Pereira, R. (2014)
Tibia and Fibula Trauma Plating Fixation
Goharian, A., & Kadir, M. R. A. (2017) · Elsevier eBooks · doi:10.1016/b978-0-12-804634-0.00013-6
Usman, U., & Huang, S. (2017) · MATEC Web of Conferences · doi:10.1051/matecconf/201710813005
Hajizadeh, M., Oskouei, A. H., Ghalichi, F., & Sole, G. (2017) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519417500920
Módulos elásticos equivalentes para predicción de deformaciones en articulaciones
Marinelli, F., Weiss, B. A., Berli, M. E., & Paolo, J. D. (2018) · Ingenius · doi:10.17163/ings.n20.2018.07
Cementless Tibial Base Micromotion During Activities of Daily Living
Wilson, H. (2018) · Digital Commons - DU (University of Denver)
Biotribology of the natural ankle joint
Kuganenderan, N. (2018) · White Rose eTheses Online (University of Leeds, The University of Sheffield, University of York)
Yamada, E., Fukuda, W., Kataoka, Y., Ikeno, Y., KAWAKAMI, S., AOSHIBA, T., MURAMOTO, H., Shimizu, R., SUSAKI, H., SAKAI, J., et al. (2019) · Rigakuryoho Kagaku · doi:10.1589/rika.34.27
Belastung und Beanspruchung der unteren Extremität
Köppel, M., & Hamacher, D. (2019) · B&G Bewegungstherapie und Gesundheitssport · doi:10.1055/a-0818-7871
A Novel Walking Cane With Haptic Biofeedback Reduces Degenerative Loading in the Arthritic Knee
Schuster, E. (2019) · Case Medical Research · doi:10.31525/ct1-nct03900052
Snethen, K., Hernandez, J. I., & Harman, M. K. (2019) · Journal of the mechanical behavior of biomedical materials/Journal of mechanical behavior of biomedical materials · doi:10.1016/j.jmbbm.2019.04.018
Nejad, S. E., Ganjeh, S. A., Charati, J. Y., & Hosseininejad, S. E. (2019) · Iranian Journal of Ergonomics · doi:10.30699/jergon.6.4.37
Deacy, J. S. (2019) · Digital Commons - DU (University of Denver)
Wang, S., Liu, Z., FENG, J., Deng, L., & Zheng, N. N. (2019) · Journal of Mechanics in Medicine and Biology · doi:10.1142/s0219519419500283
Quantifying musculoskeletal reserve in the elderly
Smith, S. H. L. (2017) · Spiral (Imperial College London) · doi:10.25560/71313
Techniques of High Tibial Osteotomy: A Review
Aqil, M. J., Gang, L., Nawabi, A. Q., Wei, J.-N., & Haidari, N. A. (2020) · Open Journal of Orthopedics · doi:10.4236/ojo.2020.105011
Jamil, M. M. A., Wahab, M. H. A., Soon, C. F., Pasko, K. M., & Youseffi, M. (2020) · Journal of Physics Conference Series · doi:10.1088/1742-6596/1529/2/022022
Rosario, R. A., Marchi, B. C., Arruda, E. M., & Coleman, R. M. (2020) · Journal of Biomechanical Engineering · doi:10.1115/1.4047658
Kingston, D. C., & Acker, S. M. (2020) · Journal of Applied Biomechanics · doi:10.1123/jab.2019-0335
Reprint of "The detection of knee joint sounds at defined loads by means of vibroarthrography"
Kalo, K., Niederer, D., Sus, R., Sohrabi, K., Banzer, W. B., Groß, V., & Vogt, L. (2020) · Clinical Biomechanics · doi:10.1016/j.clinbiomech.2020.105175
Verlaan, L. (2020) · doi:10.26481/dis.20210122lv
Simkheada, T. (2019) · UEF eRepo (University of Eastern Finland)
Metadata
- Authors
- Kutzner, I., Heinlein, B., Graichen, F., Bender, A., Rohlmann, A., Halder, A., Beier, A., & Bergmann, G.
- Affiliations
- Charité – Universitätsmedizin Berlin (DE)
- Berlin-Brandenburger Centrum für Regenerative Therapien (DE)
- Corresponding author
- Kutzner, I.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2010-08
- Volume
- 43
- Issue
- 11
- Pages
- 2164-2173
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W1972617433
- Cited by
- 798
- References
- 19
- Citations by year
- 2026: 55 · 2025: 48 · 2024: 42 · 2023: 38 · 2022: 66 · 2021: 49 · 2020: 52 · 2019: 70 · 2018: 65 · 2017: 56 · 2016: 49 · 2015: 49 · 2014: 51 · 2013: 50 · 2012: 28
- FWCI
- 36.06
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- Locations
- Journal of Biomechanics (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Surgery › Total Knee Arthroplasty Outcomes
- Health Sciences › Medicine › Surgery › Knee injuries and reconstruction techniques
- Physical Sciences › Engineering › Biomedical Engineering › Lower Extremity Biomechanics and Pathologies
- Keywords
- knee joint loading, activities of daily living, in vivo measurement, shear force, stair climbing, walking, knee flexion
- MeSH terms
- Activities of Daily Living, Aged, Computer Simulation, Female, Humans, Knee Joint, Male, Middle Aged, Models, Biological, Stress, Mechanical, Weight-Bearing
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review