Biomedical microfluidic devices by using low-cost fabrication techniques: A review
Open accessThe DOI matches its Crossref record; 90 of the 90 references it cites were found in a registry or an index.
Abstract
One of the most popular methods to fabricate biomedical microfluidic devices is by using a soft-lithography technique. However, the fabrication of the moulds to produce microfluidic devices, such as SU-8 moulds, usually requires a cleanroom environment that can be quite costly. Therefore, many efforts have been made to develop low-cost alternatives for the fabrication of microstructures, avoiding the use of cleanroom facilities. Recently, low-cost techniques without cleanroom facilities that feature aspect ratios more than 20, for fabricating those SU-8 moulds have been gaining popularity among biomedical research community. In those techniques, Ultraviolet (UV) exposure equipment, commonly used in the Printed Circuit Board (PCB) industry, replaces the more expensive and less available Mask Aligner that has been used in the last 15 years for SU-8 patterning. Alternatively, non-lithographic low-cost techniques, due to their ability for large-scale production, have increased the interest of the industrial and research community to develop simple, rapid and low-cost microfluidic structures. These alternative techniques include Print and Peel methods (PAP), laserjet, solid ink, cutting plotters or micromilling, that use equipment available in almost all laboratories and offices. An example is the xurography technique that uses a cutting plotter machine and adhesive vinyl films to generate the master moulds to fabricate microfluidic channels. In this review, we present a selection of the most recent lithographic and non-lithographic low-cost techniques to fabricate microfluidic structures, focused on the features and limitations of each technique. Only microfabrication methods that do not require the use of cleanrooms are considered. Additionally, potential applications of these microfluidic devices in biomedical engineering are presented with some illustrative examples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687 · cited 2×
“, 1997), and emerged as an attractive alternative to glass and silicon, due to their low-cost, wide range of mechanical and chemical properties, flexibility and easy processing (Whitesides, 2006; Patel et al., 2008; Pinto et al., 2014; Wong and Ho, 2009).”
BackgroundQuantitative Monitoring of Gene Expression Patterns with a Complementary DNA Microarray
Schena, M., Shalon, D., Davis, R. W., & Brown, P. O. (1995) · Science · doi:10.1126/science.270.5235.467 · Cited by 9,609
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Geometric Control of Cell Life and Death
Chen, C. S., Mrksich, M., Huang, S., Whitesides, G. M., & Ingber, D. E. (1997) · Science · doi:10.1126/science.276.5317.1425 · Cited by 4,657
Xia, Y., & Whitesides, G. M. (1998) · Annual Review of Materials Science · doi:10.1146/annurev.matsci.28.1.153 · Cited by 4,611
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Engineering Flows in Small Devices: Microfluidics Toward a Lab-on-a-Chip
Stone, H. A., Stroock, A. D., & Ajdari, A. (2004) · Annual Review of Fluid Mechanics · doi:10.1146/annurev.fluid.36.050802.122124 · Cited by 3,666
Fabrication of microfluidic systems in poly(dimethylsiloxane)
McDonald, J. C., Duffy, D. C., Anderson, J. R., Chiu, D. T., Wu, H., Schueller, O. J. A., & Whitesides, G. M. (2000) · Electrophoresis · doi:10.1002/(sici)1522-2683(20000101)21:1<27::aid-elps27>3.0.co;2-c · Cited by 3,329
Miniaturized total chemical analysis systems: A novel concept for chemical sensing
Manz, A., Graber, N., & Widmer, H. M. (1990) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(90)80209-i · Cited by 3,122
The present and future role of microfluidics in biomedical research
Sackmann, E. K., Fulton, A. L., & Beebe, D. J. (2014) · Nature · doi:10.1038/nature13118 · Cited by 2,995
Cited by
Properties and Applications of PDMS for Biomedical Engineering: A Review
Miranda, I., Souza, A., Sousa, P., Ribeiro, J., Castanheira, E. M. S., Lima, R., & Minas, G. (2021) · Journal of Functional Biomaterials · doi:10.3390/jfb13010002 · Cited by 824
Self-citationFabrication and Applications of Microfluidic Devices: A Review
Niculescu, A.-G., Chircov, C., Bîrcă, A. C., & Grumezescu, A. M. (2021) · International Journal of Molecular Sciences · doi:10.3390/ijms22042011 · Cited by 678
Gale, B. K., Jafek, A. R., Lambert, C. J., Goenner, B. L., Moghimifam, H., Nze, U. C., & Kamarapu, S. K. (2018) · Inventions · doi:10.3390/inventions3030060 · Cited by 511
Active and passive micromixers: A comprehensive review
Bayareh, M., Ashani, M. N., & Usefian, A. (2020) · Chemical Engineering and Processing - Process Intensification · doi:10.1016/j.cep.2019.107771 · Cited by 500
3D printing for chemical, pharmaceutical and biological applications
Capel, A. J., Rimington, R. P., Lewis, M. P., & Christie, S. D. R. (2018) · Nature Reviews Chemistry · doi:10.1038/s41570-018-0058-y · Cited by 312
Nasiri, R., Shamloo, A., Ahadian, S., Amirifar, L., Akbari, J., Goudie, M. J., Lee, K., Ashammakhi, N., Dokmeci, M. R., Di Carlo, D., et al. (2020) · Small · doi:10.1002/smll.202000171 · Cited by 244
Machine learning enables design automation of microfluidic flow-focusing droplet generation
Lashkaripour, A., Rodriguez, C., Mehdipour, N., Mardian, R., McIntyre, D., Ortiz, L., Campbell, J., & Densmore, D. (2021) · Nature Communications · doi:10.1038/s41467-020-20284-z · Cited by 236
Biomedical Applications of Microfluidic Devices: A Review
Gharib, G., Bütün, İ., Muganlı, Z., Kozalak, G., Namlı, İ., Sarraf, S. S., Ahmadi, V. E., Toyran, E., van Wijnen, A. J., & Koşar, A. (2022) · Biosensors · doi:10.3390/bios12111023 · Cited by 215
Miranda, B., Rea, I., Dardano, P., De Stefano, L., & Forestiere, C. (2021) · Biosensors · doi:10.3390/bios11040107 · Cited by 63
“Polydimethylsiloxane (PDMS), an organosilicon compound that has been widely used to realize microfluidic devices, as well as medical devices, represents the ideal candidate due to its low-cost, high transparency in UV-Vis spectral range, and the abundance of processing techniques that have been extensively reported el…”
Background
Metadata
- Authors
- Faustino, V., Catarino, S. O., Lima, R., & Minas, G.
- Venue
- Journal of Biomechanics
- Publisher
- Elsevier BV
- Published
- 2016-07
- Volume
- 49
- Issue
- 11
- Pages
- 2280-2292
- ISSN
- 0021-9290 (ISSN-L)
- OpenAlex
- W2183793823
- Cited by
- 338
- References
- 90
- FWCI
- 9.28
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.