CoChat

A novel glucose biosensor platform based on Ag@AuNPs modified graphene oxide nanocomposite and SERS application

Open access
Gupta, Vinod Kumar, Atar, Necip, Yola, Mehmet Lütfi, Eryılmaz, Merve, Torul, Hilal, Tamer, Uğur, Boyacı, İsmail Hakkı, Üstündağ, Zafer · 2013 · Journal of Colloid and Interface Science
Cited by 138

The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.

Abstract

This study represents a novel template demonstration of a glucose biosensor based on mercaptophenyl boronic acid (MBA) terminated Ag@AuNPs/graphene oxide (Ag@AuNPs-GO) nanomaterials. The nanocomposites were characterized by transmission electron microscopy (TEM), X-ray photoelectron spectroscopy (XPS), and X-ray diffraction (XRD) method. The TEM image shows that Ag@AuNPs in the nanocomposite is in the range of diameters of 10-20 nm. The nanocomposite was used for the determination of glucose through the complexation between boronic acid and diol groups of glucose. Thus, a novel glucose biosensor was further fabricated by immobilizing glucose oxidase (GOD) into MBA terminated Ag@AuNPs-GO nanocomposite film (MBA-Ag@AuNPs-GO). The linearity range of glucose was obtained as 2-6mM with detection limit of 0.33 mM. The developed biosensor was also applied successfully for the determination of glucose in blood samples. The concentration value of glucose in blood samples was calculated to be 1.97±0.002 mM from measurements repeated for six times.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcis.2013.06.007

Cites

7 of 7 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 7 references

Cited by

See all 138

Metadata

Authors
Gupta, V. K., Atar, N., Yola, M. L., Eryılmaz, M., Torul, H., Tamer, U., Boyacı, İ. H., & Üstündağ, Z.
Venue
Journal of Colloid and Interface Science
Publisher
Elsevier BV
Published
2013-09
Volume
406
Pages
231-237
ISSN
0021-9797 (ISSN-L)
OpenAlex
W2083973410
Cited by
138
References
7
FWCI
9.99
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A novel glucose biosensor platform based on Ag@AuNPs modified graphene oxide nanocomposite and SERS application. https://app.cochat.ai/papers/10.1016/j.jcis.2013.06.007
The paper
Gupta, V. K., Atar, N., Yola, M. L., Eryılmaz, M., Torul, H., Tamer, U., Boyacı, İ. H., & Üstündağ, Z. (2013). A novel glucose biosensor platform based on Ag@AuNPs modified graphene oxide nanocomposite and SERS application. Journal of Colloid and Interface Science. https://doi.org/10.1016/j.jcis.2013.06.007

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.