The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Fully Automated, Quality-Controlled Cardiac Analysis From CMR
Open accessAbstract
OBJECTIVES: This study sought to develop a fully automated framework for cardiac function analysis from cardiac magnetic resonance (CMR), including comprehensive quality control (QC) algorithms to detect erroneous output. BACKGROUND: Analysis of cine CMR imaging using deep learning (DL) algorithms could automate ventricular function assessment. However, variable image quality, variability in phenotypes of disease, and unavoidable weaknesses in training of DL algorithms currently prevent their use in clinical practice. METHODS: The framework consists of a pre-analysis DL image QC, followed by a DL algorithm for biventricular segmentation in long-axis and short-axis views, myocardial feature-tracking (FT), and a post-analysis QC to detect erroneous results. The study validated the framework in healthy subjects and cardiac patients by comparison against manual analysis (n = 100) and evaluation of the QC steps' ability to detect erroneous results (n = 700). Next, this method was used to obtain reference values for cardiac function metrics from the UK Biobank. RESULTS: Automated analysis correlated highly with manual analysis for left and right ventricular volumes (all r > 0.95), strain (circumferential r = 0.89, longitudinal r > 0.89), and filling and ejection rates (all r ≥ 0.93). There was no significant bias for cardiac volumes and filling and ejection rates, except for right ventricular end-systolic volume (bias +1.80 ml; p = 0.01). The bias for FT strain was <1.3%. The sensitivity of detection of erroneous output was 95% for volume-derived parameters and 93% for FT strain. Finally, reference values were automatically derived from 2,029 CMR exams in healthy subjects. CONCLUSIONS: The study demonstrates a DL-based framework for automated, quality-controlled characterization of cardiac function from cine CMR, without the need for direct clinician oversight.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A survey on deep learning in medical image analysis
Litjens, G., Kooi, T., Bejnordi, B. E., Setio, A. A. A., Ciompi, F., Ghafoorian, M., van der Laak, J. A. W. M., van Ginneken, B., & Sánchez, C. I. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.07.005 · Cited by 15,332
Automated cardiovascular magnetic resonance image analysis with fully convolutional networks
Bai, W., Sinclair, M., Tarroni, G., Oktay, O., Rajchl, M., Vaillant, G., Lee, A. M., Aung, N., Lukaschuk, E., Sanghvi, M. M., et al. (2018) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-018-0471-x · Cited by 773
Self-citationUK Biobank's cardiovascular magnetic resonance protocol
Petersen, S. E., Matthews, P. M., Francis, J. M., Robson, M. D., Zemrak, F., Boubertakh, R., Young, A. A., Hudson, S., Weale, P., Garratt, S., et al. (2016) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-016-0227-4 · Cited by 481
FUIQA: Fetal Ultrasound Image Quality Assessment with Deep Convolutional Networks
Wu, L., Cheng, J.-Z., Li, S., Lei, B., Wang, T., & Ni, D. (2017) · IEEE Transactions on Cybernetics · doi:10.1109/tcyb.2017.2671898 · Cited by 242
Medrano-Gracia, P., Cowan, B. R., Ambale-Venkatesh, B., Bluemke, D. A., Eng, J., Finn, J. P., Fonseca, C. G., Lima, J. A., Suinesiaputra, A., & Young, A. A. (2014) · Journal of Cardiovascular Magnetic Resonance · doi:10.1186/s12968-014-0056-2 · Cited by 98
Automatic Quality Control of Cardiac MRI Segmentation in Large-Scale Population Imaging
Robinson, R., Valindria, V. V., Bai, W., Suzuki, H., Matthews, P. M., Page, C., Rueckert, D., & Glocker, B. (2017) · Lecture Notes in Computer Science · doi:10.1007/978-3-319-66182-7_82 · Cited by 37
Self-citation
Cited by
Deep Learning for Cardiac Image Segmentation: A Review
Chen, C., Qin, C., Qiu, H., Tarroni, G., Duan, J., Bai, W., & Rueckert, D. (2020) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2020.00025 · Cited by 869
Self-citationPuyol-Antón, E., Ruijsink, B., Mariscal Harana, J., Piechnik, S. K., Neubauer, S., Petersen, S. E., Razavi, R., Chowienczyk, P., & King, A. P. (2022) · Frontiers in Cardiovascular Medicine · doi:10.3389/fcvm.2022.859310 · Cited by 85
Self-citationGlobal and Local Interpretability for Cardiac MRI Classification
Clough, J. R., Oksuz, I., Puyol-Antón, E., Ruijsink, B., King, A. P., & Schnabel, J. A. (2019) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-32251-9_72 · Cited by 73
Self-citationMastrodicasa, D., van Assen, M., Huisman, M., Leiner, T., Williamson, E. E., Nicol, E. D., Allen, B. D., Saba, L., Vliegenthart, R., & Hanneman, K. (2025) · Radiology · doi:10.1148/radiol.240516 · Cited by 69
Efficient Model Monitoring for Quality Control in Cardiac Image Segmentation
Galati, F., & Zuluaga, M. A. (2021) · Lecture Notes in Computer Science · doi:10.1007/978-3-030-78710-3_11 · Cited by 15
Metadata
- Authors
- Ruijsink, B., Puyol-Antón, E., Oksuz, I., Sinclair, M., Bai, W., Schnabel, J. A., Razavi, R., & King, A. P.
- Venue
- JACC: Cardiovascular Imaging
- Publisher
- Elsevier BV
- Published
- 2020-03
- Volume
- 13
- Issue
- 3
- Pages
- 684-695
- ISSN
- 1876-7591 (ISSN-L)
- 1936-878X
- OpenAlex
- W2956767972
- Cited by
- 182
- References
- 6
- FWCI
- 15.15
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fully Automated, Quality-Controlled Cardiac Analysis From CMR. https://app.cochat.ai/papers/10.1016/j.jcmg.2019.05.030
- The paper
- Ruijsink, B., Puyol-Antón, E., Oksuz, I., Sinclair, M., Bai, W., Schnabel, J. A., Razavi, R., & King, A. P. (2020). Fully Automated, Quality-Controlled Cardiac Analysis From CMR. JACC: Cardiovascular Imaging. https://doi.org/10.1016/j.jcmg.2019.05.030
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.