CoChat

Warranty Period of a Calcium Score of Zero

Open access
Dzaye, Omar, Dardari, Zeina A., Cainzos-Achirica, Miguel, Blankstein, Ron, Agatston, Arthur S., Duebgen, Matthias, Yeboah, Joseph, Szklo, Moyses, Budoff, Matthew J., Lima, Joao A.C., Blumenthal, Roger S., Nasir, Khurram, Blaha, Michael J. · 2021 · JACC: Cardiovascular Imaging
Cited by 128

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Objectives. To quantify and model conversion of a normal to an abnormal coronary artery calcium (CAC) scan. Background. While absence of CAC is associated with excellent prognosis, progression to CAC>0 confers increased risk. The time interval for repeat scanning remains poorly defined. Methods. Our study included 3,116 participants from the Multi-Ethnic Study of Atherosclerosis (MESA) with baseline CAC=0 and follow-up scans over 10 years after baseline. Prevalence of incident CAC, defined by thresholds of either CAC>0, CAC>10, or CAC>100, was calculated and time-to-progression was derived from a Weibull parametric survival model. Warranty periods were modeled as a function of sex, race/ethnicity, cardiovascular risk, and desired yield of repeat CAC testing. We further analyzed the proportion of coronary events occurring in participants with baseline CAC=0 that precede and follow repeat CAC testing at different time intervals. Results. Mean age was 58 ± 9 years, with 63% women, and mean 10-year cardiovascular risk of 14%. Prevalence of CAC>0, CAC>10, and CAC>100 was 53%, 36%, and 8% respectively at 10 years. Using a 25% testing yield (Number Needed to Scan=4) the estimated warranty period of CAC>0 varied between 3 to 7 years depending on sex and race/ethnicity. Approximately 15% progressed to CAC>10 in 5 to 8 years, while 10-year progression to CAC>100 was rare. Presence of diabetes was associated with significantly shorter warranty period, while family history and smoking had small effects. 19% of all 10-year coronary events occurred in CAC=0 prior to performance of a subsequent scan at 3–5 years, while new detection of CAC>0 preceded 55% of future events and identified individuals at 3-fold higher risk of coronary events. Conclusion. In a large population of individuals with baseline CAC=0, we provide a robust estimation of the CAC=0 warranty period, considering progression to CAC>0, CAC>10, and CAC>100, and impact on missed vs. detectable 10-year year CHD events. Beyond age and sex, race/ethnicity and diabetes also have a significant impact on the warranty period. We suggest that evidence-based guidance would be to consider rescanning in 3 to 7 years depending on individual demographics and risk profile.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcmg.2020.06.048

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

Metadata

Authors
Dzaye, O., Dardari, Z. A., Cainzos-Achirica, M., Blankstein, R., Agatston, A. S., Duebgen, M., Yeboah, J., Szklo, M., Budoff, M. J., Lima, J. A. C., Blumenthal, R. S., Nasir, K., & Blaha, M. J.
Venue
JACC: Cardiovascular Imaging
Publisher
Elsevier BV
Published
2021-05
Volume
14
Issue
5
Pages
990-1002
ISSN
  • 1876-7591 (ISSN-L)
  • 1936-878X
OpenAlex
W3096815484
Cited by
128
References
8
FWCI
7.06
Type
journal article
Language
en
Open access
bronze

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.