Towards nanomedicines of the future: Remote magneto-mechanical actuation of nanomedicines by alternating magnetic fields
Open accessThe DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Abstract
The paper describes the concept of magneto-mechanical actuation of single-domain magnetic nanoparticles (MNPs) in super-low and low frequency alternating magnetic fields (AMFs) and its possible use for remote control of nanomedicines and drug delivery systems. The applications of this approach for remote actuation of drug release as well as effects on biomacromolecules, biomembranes, subcellular structures and cells are discussed in comparison to conventional strategies employing magnetic hyperthermia in a radio frequency (RF) AMF. Several quantitative models describing interaction of functionalized MNPs with single macromolecules, lipid membranes, and proteins (e.g. cell membrane receptors, ion channels) are presented. The optimal characteristics of the MNPs and an AMF for effective magneto-mechanical actuation of single molecule responses in biological and bio-inspired systems are discussed. Altogether, the described studies and phenomena offer opportunities for the development of novel therapeutics both alone and in combination with magnetic hyperthermia.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Magnetic fluid hyperthermia: focus on superparamagnetic iron oxide nanoparticles
Laurent, S., Dutz, S., Häfeli, U. O., & Mahmoudi, M. (2011) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2011.04.003 · Cited by 1,326
Biomechanics and biophysics of cancer cells☆
SURESH, S. (2007) · Acta Biomaterialia · doi:10.1016/j.actbio.2007.04.002 · Cited by 1,284
Dynamic molecular processes mediate cellular mechanotransduction
Hoffman, B. D., Grashoff, C., & Schwartz, M. A. (2011) · Nature · doi:10.1038/nature10316 · Cited by 956
Guardia, P., Di Corato, R., Lartigue, L., Wilhelm, C., Espinosa, A., Garcia-Hernandez, M., Gazeau, F., Manna, L., & Pellegrino, T. (2012) · ACS Nano · doi:10.1021/nn2048137 · Cited by 752
Electromagnetic effects—From cell biology to medicine
Funk, R. H. W., Monsees, T., & Özkucur, N. (2009) · Progress in Histochemistry and Cytochemistry · doi:10.1016/j.proghi.2008.07.001 · Cited by 423
Amstad, E., Kohlbrecher, J., Müller, E., Schweizer, T., Textor, M., & Reimhult, E. (2011) · Nano Letters · doi:10.1021/nl2001499 · Cited by 397
Magnetoliposomes for controlled drug release in the presence of low-frequency magnetic field
Nappini, S., Bombelli, F. B., Bonini, M., Nordèn, B., & Baglioni, P. (2010) · Soft Matter · doi:10.1039/b915651h · Cited by 113
Cited by
Nano based drug delivery systems: recent developments and future prospects
Patra, J. K., Das, G., Fraceto, L. F., Campos, E. V. R., Rodriguez-Torres, M. D. P., Acosta-Torres, L. S., Diaz-Torres, L. A., Grillo, R., Swamy, M. K., Sharma, S., et al. (2018) · Journal of Nanobiotechnology · doi:10.1186/s12951-018-0392-8 · Cited by 6,684
External triggering and triggered targeting strategies for drug delivery
Wang, Y., & Kohane, D. S. (2017) · Nature Reviews Materials · doi:10.1038/natrevmats.2017.20 · Cited by 418
Lipid nanoparticles for targeted siRNA delivery - going from bench to bedside
Zatsepin (2016) · International Journal of Nanomedicine · doi:10.2147/ijn.s106625 · Cited by 162
“36 As we mentioned earlier, the main problem in targeted delivery of RNA, besides the escape from endosomes after cell penetration, is the specific and efficient delivery to the appropriate cell types of the tissue of interest.”
Li, B., Zu, M., Jiang, A., Cao, Y., Wu, J., Shahbazi, M.-A., Shi, X., Reis, R. L., Kundu, S. C., & Xiao, B. (2024) · Biomaterials · doi:10.1016/j.biomaterials.2024.122530 · Cited by 67
Riaz, S., Ali, S., Summer, M., Akhtar, U., Noor, S., Haqqi, R., Farooq, M. A., & Sardar, I. (2025) · Annals of Biomedical Engineering · doi:10.1007/s10439-025-03712-3 · Cited by 38
Metadata
- Authors
- Golovin, Y. I., Gribanovsky, S. L., Golovin, D. Y., Klyachko, N. L., Majouga, A. G., Master, А. M., Sokolsky, M., & Kabanov, A. V.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2015-12
- Volume
- 219
- Pages
- 43-60
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W1757165467
- Cited by
- 232
- References
- 7
- FWCI
- 6.86
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Towards nanomedicines of the future: Remote magneto-mechanical actuation of nanomedicines by alternating magnetic fields. https://app.cochat.ai/papers/10.1016/j.jconrel.2015.09.038
- The paper
- Golovin, Y. I., Gribanovsky, S. L., Golovin, D. Y., Klyachko, N. L., Majouga, A. G., Master, А. M., Sokolsky, M., & Kabanov, A. V. (2015). Towards nanomedicines of the future: Remote magneto-mechanical actuation of nanomedicines by alternating magnetic fields. Journal of Controlled Release. https://doi.org/10.1016/j.jconrel.2015.09.038
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.