Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening
Open accessThe DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Abstract
Focused ultrasound (FUS) in combination with systemically injected microbubbles can be used to non-invasively open the blood-brain barrier (BBB) in targeted regions for a variety of therapeutic applications. Over the past two decades, preclinical research into the safety and efficacy of FUS-induced BBB opening has proven this technique to be transient and efficacious, propelling FUS-induced BBB opening into several clinical trials in recent years. However, as clinical trials further progress, the neuroinflammatory response to FUS-induced BBB opening needs to be better understood. In this study, we provide further insight into the relationship of microbubble cavitation and the resulting innate immune response to FUS-induced BBB opening. By keeping ultrasound parameters fixed (i.e. frequency, pressure, pulse length, etc.), three groups of mice were sonicated using a real-time cavitation controller until a target cavitation dose was reached (1 x 107 V2•s, 5 x 107 V2•s, 1 x 108 V2•s). The change in relative gene expression of the mouse inflammatory cytokines and receptors were evaluated at three different time-points (6 h, 24 h, and 72 h) after FUS. At both 6 and 24 h time-points, significant changes in relative gene expression of inflammatory cytokines and receptors were observed across all cavitation groups. However, the degree of changes in relative expression levels and the number of genes with significant changes in expression varied across the cavitation groups. Groups with a higher cavitation dose exhibited both greater changes in relative expression levels and greater number of significant changes. By 72 h, the gene expression levels returned to baseline in all cavitation dose groups, signifying a transient inflammatory response to FUS-induced BBB opening at the targeted cavitation dose levels. Furthermore, the real-time cavitation controller was able to produce consistent and significantly different BBB permeability enhancement volumes across the three different cavitation dose groups. These results indicate that cavitation monitoring and controlling during FUS-induced BBB opening can be used to potentially modulate or limit the degree of neuroinflammation, further emphasizing the importance of implementing cavitation controllers as FUS-induced BBB opening is translated into the clinic.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Analysis of Relative Gene Expression Data Using Real-Time Quantitative PCR and the 2−ΔΔCT Method
Livak, K. J., & Schmittgen, T. D. (2001) · Methods · doi:10.1006/meth.2001.1262 · Cited by 180,860
Monocyte Chemoattractant Protein-1 (MCP-1): An Overview
Deshmane, S. L., Kremlev, S., Amini, S., & Sawaya, B. E. (2009) · Journal of Interferon & Cytokine Research · doi:10.1089/jir.2008.0027 · Cited by 3,889
Blood-brain barrier opening in Alzheimer’s disease using MR-guided focused ultrasound
Lipsman, N., Meng, Y., Bethune, A. J., Huang, Y., Lam, B., Masellis, M., Herrmann, N., Heyn, C., Aubert, I., Boutet, A., et al. (2018) · Nature Communications · doi:10.1038/s41467-018-04529-6 · Cited by 950
Scanning ultrasound removes amyloid-β and restores memory in an Alzheimer’s disease mouse model
Leinenga, G., & Götz, J. (2015) · Science Translational Medicine · doi:10.1126/scitranslmed.aaa2512 · Cited by 498
Disrupting the blood–brain barrier by focused ultrasound induces sterile inflammation
Kovacs, Z. I., Kim, S., Jikaria, N., Qureshi, F., Milo, B., Lewis, B. K., Bresler, M., Burks, S. R., & Frank, J. A. (2017) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1614777114 · Cited by 458
Jordão, J. F., Thévenot, E., Markham-Coultes, K., Scarcelli, T., Weng, Y.-Q., Xhima, K., O'Reilly, M., Huang, Y., McLaurin, J., Hynynen, K., et al. (2013) · Experimental Neurology · doi:10.1016/j.expneurol.2013.05.008 · Cited by 326 · cited 1×
“The safety profile of this intervention has been evaluated in both wild-type and diseased model animals through a plethora of safety metrics including T2-weighted and susceptibility-weighted imaging (SWI) to assess edema and hemorrhage [20,21], hematoxylin and eosin (H&E) staining to assess histological changes such a…”
MethodBurgess, A., Dubey, S., Yeung, S., Hough, O., Eterman, N., Aubert, I., & Hynynen, K. (2014) · Radiology · doi:10.1148/radiol.14140245 · Cited by 286
Sonoselective transfection of cerebral vasculature without blood–brain barrier disruption
Gorick, C. M., Mathew, A. S., Garrison, W. J., Thim, E. A., Fisher, D. G., Copeland, C. A., Song, J., Klibanov, A. L., Miller, G. W., & Price, R. J. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1914595117 · Cited by 57
Microbubble formulation influences inflammatory response to focused ultrasound exposure in the brain
McMahon, D., Lassus, A., Gaud, E., Jeannot, V., & Hynynen, K. (2020) · Scientific Reports · doi:10.1038/s41598-020-78657-9 · Cited by 52 · cited 1×
“Moreover, the requirement of multiple bolus injections for the higher CCD groups may have an effect on the expression levels, as a recent publication has shown that the inflammatory response following FUS induced BBB opening was influenced by the microbubble formulation itself, including the size distribution and tota…”
Background
Cited by
Wang, J., Li, Z., Pan, M., Fiaz, M., Hao, Y., Yan, Y., Sun, L., & Yan, F. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114539 · Cited by 161
Bae, S., Liu, K., Pouliopoulos, A. N., Ji, R., Jiménez-Gambín, S., Yousefian, O., Kline-Schoder, A. R., Batts, A. J., Tsitsos, F. N., Kokossis, D., et al. (2024) · Theranostics · doi:10.7150/thno.94206 · Cited by 70
“In this study, statistically significant relationships between the opening size and harmonic, ultraharmonic, and broadband cavitation energies were detected (Figure 5C), consistent with our preclinical studies with mice and NHPs [33,48,49].”
Self-citationNoel, R. L., Batts, A. J., Ji, R., Pouliopoulos, A. N., Bae, S., Kline-Schoder, A. R., & Konofagou, E. E. (2023) · Scientific Reports · doi:10.1038/s41598-023-30466-6 · Cited by 27
Self-citationKang, Z., Yang, M., Feng, X., Liao, H., Zhang, Z., & Du, Y. (2022) · International Journal of Nanomedicine · doi:10.2147/ijn.s360161 · Cited by 21
“It may be related to the fact that inertial cavitation prompted by A-DPPs can enhance heating at the focus, increase chemotherapeutic potency, elevate mechanical and, more importantly, biological effects of FUS.56–58 As for the biological effects, bubble collapse by cavitation can generate shock waves and micro-jets n…”
BackgroundInfluentialFocused ultrasound‐mediated APOE4 knockdown in mouse brain
Zheng, K., Tsitsos, F. N., Batts, A. J., Ji, R., Nuriel, T., Konofagou, E. E., & Leong, K. W. (2025) · Alzheimer's & Dementia · doi:10.1002/alz.70464 · Cited by 8
Self-citation
Metadata
- Authors
- Ji, R., Karakatsani, M. E., Burgess, M., Smith, M., Murillo, M. F., & Konofagou, E. E.
- Venue
- Journal of Controlled Release
- Publisher
- Elsevier BV
- Published
- 2021-09
- Volume
- 337
- Pages
- 458-471
- ISSN
- 0168-3659 (ISSN-L)
- OpenAlex
- W3185072862
- Cited by
- 109
- References
- 9
- FWCI
- 4.76
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening. https://app.cochat.ai/papers/10.1016/j.jconrel.2021.07.042
- The paper
- Ji, R., Karakatsani, M. E., Burgess, M., Smith, M., Murillo, M. F., & Konofagou, E. E. (2021). Cavitation-modulated inflammatory response following focused ultrasound blood-brain barrier opening. Journal of Controlled Release. https://doi.org/10.1016/j.jconrel.2021.07.042
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.