CoChat

Effect of decentration and tilt on the image quality of aspheric intraocular lens designs in a model eye

Eppig, Timo, Scholz, Katja, Löffler, André, Meßner, Arthur, Langenbucher, Achim · 2009 · Journal of Cataract and Refractive Surgery
Cited by 185

The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.

Abstract

PURPOSE: To determine the impact of decentration and tilt on the imaging quality of aspheric intraocular lens (IOL) designs in a schematic model eye. SETTING: Institute of Medical Physics, University of Erlangen-Nuremberg, Erlangen, Germany. METHOD: A model eye was used to calculate the impact of misalignment on the imaging quality of 6 IOL designs. The crystalline lens in the model eye was replaced with IOL designs with 22.0 diopters nominal refractive power, and the anterior chamber depth (ACD) was set to the estimated ACD value provided by the manufacturer. The retinal position was optimized for the best image quality. The IOLs were decentered up to +/-1.0 mm and tilted up to +/-5 degrees relative to the line of sight. At each position, the modulation transfer function was recorded with 3.0 mm and 4.5 mm pupil diameters. The results between the IOL designs and those of the phakic model eye were then compared. RESULTS: Aberration-correcting IOLs were very sensitive to decentration and tilt. However, the impact of misalignment depended on IOL design. Aberration-free IOLs showed less sensitivity within a wide range of displacement but provided better results than the spherical IOL. CONCLUSIONS: Overall, modern aspheric IOLs provided better imaging quality than conventional spherical IOL designs. Aberration-free IOLs were less sensitive to decentration and tilt than aberration-correcting IOLs but provided better image quality than spherical IOLs. Aberration-correcting IOLs have the potential to provide diffraction-limited imaging quality when perfectly aligned.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcrs.2009.01.034

Cites

12 of 12 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Cited by

See all 185

Metadata

Authors
Eppig, T., Scholz, K., Löffler, A., Meßner, A., & Langenbucher, A.
Venue
Journal of Cataract and Refractive Surgery
Published
2009-06
Volume
35
Issue
6
Pages
1091-1100
ISSN
  • 0146-2776 (ISSN-L)
  • 0886-3350
OpenAlex
W2000419123
Cited by
185
References
12
FWCI
8.87
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.