PURPOSE: To compare the intraoperative complications and safety of femtosecond laser-assisted cataract surgery and conventional phacoemulsification cataract surgery. SETTING: Single center. DESIGN: Prospective consecutive comparative cohort case series. METHODS: Eyes had femtosecond laser-assisted cataract surgery (study group) or phacoemulsification (control group) by 1 of 5 surgeons. The technique comprised manual corneal incisions and capsulorhexis or laser-assisted anterior capsulotomy, lens fragmentation, corneal incisions, phacoemulsification, and intraocular lens implantation. RESULTS: The study group comprised 1852 eyes and the control group, 2228 eyes. Patient demographics were similar between groups. There was a significant improvement in vacuum/docking attempts, surface recognition adjustments, treatment, and vacuum time during the laser procedure in the study group. Anterior capsule tears occurred in 1.84% of eyes in the study group and 0.22% of eyes in the control group (P < .0001). There was no difference in the incidence of anterior capsule tears between the first half and second half of laser-assisted cases. Anterior capsulotomy tags occurred in 1.62% study group eyes. There was no significant difference in posterior capsule tears between the 2 groups (0.43% versus 0.18%). The incidence of significant intraoperative corneal haze and miosis was higher and the effective phacoemulsification time significantly lower in the study group (P < .001). CONCLUSIONS: Significant intraoperative complications likely to affect refractive outcomes and patient satisfaction were low overall. The 2 cataract surgery techniques appear to be equally safe. Although anterior capsule tears remain a concern, the safety of femtosecond-assisted cataract surgery in terms of posterior capsule complications was equal to that of phacoemulsification. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jcrs.2014.06.025

Cites

11 of 11 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 11 references

Cited by

Metadata

Authors
Abell, R. G., Darian-Smith, E., Kan, J. B., Allen, P. L., Ewe, S. Y. P., & Vote, B. J.
Venue
Journal of Cataract and Refractive Surgery
Published
2015-01
Volume
41
Issue
1
Pages
47-52
ISSN
  • 0146-2776 (ISSN-L)
  • 0886-3350
OpenAlex
W2159657539
Cited by
160
References
11
FWCI
16.54
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.