Femtosecond laser–assisted cataract surgery versus standard phacoemulsification cataract surgery: Outcomes and safety in more than 4000 cases at a single center
Open accessThe DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
PURPOSE: To compare the intraoperative complications and safety of femtosecond laser-assisted cataract surgery and conventional phacoemulsification cataract surgery. SETTING: Single center. DESIGN: Prospective consecutive comparative cohort case series. METHODS: Eyes had femtosecond laser-assisted cataract surgery (study group) or phacoemulsification (control group) by 1 of 5 surgeons. The technique comprised manual corneal incisions and capsulorhexis or laser-assisted anterior capsulotomy, lens fragmentation, corneal incisions, phacoemulsification, and intraocular lens implantation. RESULTS: The study group comprised 1852 eyes and the control group, 2228 eyes. Patient demographics were similar between groups. There was a significant improvement in vacuum/docking attempts, surface recognition adjustments, treatment, and vacuum time during the laser procedure in the study group. Anterior capsule tears occurred in 1.84% of eyes in the study group and 0.22% of eyes in the control group (P < .0001). There was no difference in the incidence of anterior capsule tears between the first half and second half of laser-assisted cases. Anterior capsulotomy tags occurred in 1.62% study group eyes. There was no significant difference in posterior capsule tears between the 2 groups (0.43% versus 0.18%). The incidence of significant intraoperative corneal haze and miosis was higher and the effective phacoemulsification time significantly lower in the study group (P < .001). CONCLUSIONS: Significant intraoperative complications likely to affect refractive outcomes and patient satisfaction were low overall. The 2 cataract surgery techniques appear to be equally safe. Although anterior capsule tears remain a concern, the safety of femtosecond-assisted cataract surgery in terms of posterior capsule complications was equal to that of phacoemulsification. FINANCIAL DISCLOSURE: No author has a financial or proprietary interest in any material or method mentioned.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Initial Clinical Evaluation of an Intraocular Femtosecond Laser in Cataract Surgery
Nagy, Z., Takacs, A., Filkorn, T., & Sarayba, M. (2009) · Journal of Refractive Surgery · doi:10.3928/1081597x-20091117-04 · Cited by 563
Corneal refractive surgery with femtosecond lasers
Juhasz, T., Loesel, F. H., Kurtz, R. M., Horvath, C., Bille, J. F., & Mourou, G. A. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796309 · Cited by 424 · cited 1×
“Ultrashort-pulse femtosecond lasers operate at near infraredwavelengths and can be focused precisely at predetermined depths using advanced imaging technology to photodisrupt optically clear tissues while preventing collateral tissue damage.(2) The advantages of this technology over conventional phacoemulsification, i…”
BackgroundFemtosecond Laser–Assisted Cataract Surgery with Integrated Optical Coherence Tomography
Palanker, D. V., Blumenkranz, M. S., Andersen, D., Wiltberger, M., Marcellino, G., Gooding, P., Angeley, D., Schuele, G., Woodley, B., Simoneau, M., et al. (2010) · Science Translational Medicine · doi:10.1126/scitranslmed.3001305 · Cited by 277 · cited 1×
“Theapplicationof femtosecond lasers in cataract surgery allows creation of automated corneal incisions, anterior capsulotomy, and lens fragmentation.(1) Ultrashort-pulse femtosecond lasers operate at near infraredwavelengths and can be focused precisely at predetermined depths using advanced imaging technology to phot…”
BackgroundToward Zero Effective Phacoemulsification Time Using Femtosecond Laser Pretreatment
Abell, R. G., Kerr, N. M., & Vote, B. J. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.11.045 · Cited by 235 · cited 2×
“Case mix might account for the differences between surgeons; therefore, we recommend using objective measures of cataract densitometry as has been previously reported.(3,8,10) In both surgery groups, none of the eyes in which a complication occurred were noted perioperatively to have risk factors, such as a weak zonul…”
BackgroundSelf-citationSurgical Outcomes and Safety of Femtosecond Laser Cataract Surgery
Roberts, T. V., Lawless, M., Bali, S. J., Hodge, C., & Sutton, G. (2013) · Ophthalmology · doi:10.1016/j.ophtha.2012.10.026 · Cited by 230 · cited 3×
“Early studies of the short-term and long-term surgical outcomes are also emerging, and there may be an effect of a learning curve that we did not identify in our study.(6,19) Further research of the effect of femtosecond laser–assisted cataract surgery on the postoperative intraocular pressure, corneal edema, endothel…”
BackgroundEarly Experience with the Femtosecond Laser for Cataract Surgery
Bali, S. J., Hodge, C., Lawless, M., Roberts, T. V., & Sutton, G. (2012) · Ophthalmology · doi:10.1016/j.ophtha.2011.12.025 · Cited by 214
Complications of cataract surgery
Chan, E., Mahroo, O. A. R., & Spalton, D. J. (2010) · Clinical and Experimental Optometry · doi:10.1111/j.1444-0938.2010.00516.x · Cited by 199 · cited 1×
“Posterior capsule tears, unlike anterior capsule tears, are more likely to affect the effective lens position and hence the refractive outcome.(16) They also can have a significant effect on endothelial cell loss, glaucoma, cystoid macular edema, endophthalmitis, and retinal detachment when anterior vitrectomy is requ…”
BackgroundTakács, Á. I., Kovács, I., Miháltz, K., Filkorn, T., Knorz, M. C., & Nagy, Z. Z. (2012) · Journal of Refractive Surgery · doi:10.3928/1081597x-20120508-02 · Cited by 177
Effect of Femtosecond Laser Fragmentation on Effective Phacoemulsification Time in Cataract Surgery
Conrad-Hengerer, I., Hengerer, F. H., Schultz, T., & Dick, H. B. (2012) · Journal of Refractive Surgery · doi:10.3928/1081597x-20121116-02 · Cited by 162
Femtosecond laser‐assisted cataract surgery compared with conventional cataract surgery
Abell, R. G., Kerr, N. M., & Vote, B. J. T. (2012) · Clinical and Experimental Ophthalmology · doi:10.1111/ceo.12025 · Cited by 145
Self-citationFilkorn, T., Kovács, I., Takács, Á. I., Horváth, É., Knorz, M. C., & Nagy, Z. Z. (2012) · Journal of Refractive Surgery · doi:10.3928/1081597x-20120703-04 · Cited by 138
Cited by
Roberts, H. W., Wagh, V. K., Mullens, I. J. M., Borsci, S., Ni, M. Z., & O’Brart, D. P. S. (2018) · British Journal of Ophthalmology · doi:10.1136/bjophthalmol-2017-311319 · Cited by 26
Metadata
- Authors
- Abell, R. G., Darian-Smith, E., Kan, J. B., Allen, P. L., Ewe, S. Y. P., & Vote, B. J.
- Venue
- Journal of Cataract and Refractive Surgery
- Published
- 2015-01
- Volume
- 41
- Issue
- 1
- Pages
- 47-52
- ISSN
- 0146-2776 (ISSN-L)
- 0886-3350
- OpenAlex
- W2159657539
- Cited by
- 160
- References
- 11
- FWCI
- 16.54
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.