Normal values of the electrocardiogram for ages 16–90 years
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Rotterdam Study: objectives and design update
Hofman, A., Breteler, M. M. B., van Duijn, C. M., Krestin, G. P., Pols, H. A., Stricker, B. H. C., Tiemeier, H., Uitterlinden, A. G., Vingerling, J. R., & Witteman, J. C. M. (2007) · European Journal of Epidemiology · doi:10.1007/s10654-007-9199-x · Cited by 1,395
Self-citationComprehensive Electrocardiology
(2010) · Springer eBooks · doi:10.1007/978-1-84882-046-3 · Cited by 486
Luo, S., Michler, K., Johnston, P., & Macfarlane, P. W. (2004) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2004.08.030 · Cited by 454 · cited 3×
“It is well-known that Bazett's formula overcorrects for heart rates above 60 bpm [6,27].”
BackgroundResultNew normal limits for the paediatric electrocardiogram
Rijnbeek, P. (2001) · European Heart Journal · doi:10.1053/euhj.2000.2399 · Cited by 399 · cited 1×
“The data for the ages from 0 to 16 have been furnished by our previous study of normal limits for the pediatric ECG [30] and have been integrated with the adult data for measurements that were common to both studies.”
MethodSelf-citationElectrocardiographic reference ranges derived from 79,743 ambulatory subjects
Mason, J. W., Ramseth, D. J., Chanter, D. O., Moon, T. E., Goodman, D. B., & Mendzelevski, B. (2007) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2006.09.003 · Cited by 382 · cited 2×
“from 2007 comprises a much larger population of 46,129 subjects, enrolled in clinical trials and expected to be free of diseaseassociated ECG effects, but was restricted to heart rate, interval durations, and axes [8].”
BackgroundThe Rotterdam Study: 2012 objectives and design update
Hofman, A., van Duijn, C. M., Franco, O. H., Ikram, M. A., Janssen, H. L. A., Klaver, C. C. W., Kuipers, E. J., Nijsten, T. E. C., Stricker, B. H. C., Tiemeier, H., et al. (2011) · European Journal of Epidemiology · doi:10.1007/s10654-011-9610-5 · Cited by 289 · cited 1×
“This project, started in 1990, is an ongoing population-based prospective cohort study of the occurrence of cardiovascular, locomotor, neurologic, and ophthalmologic disease in the elderly [13].”
BackgroundSelf-citationDifferentiation between normal and abnormal in electrocardiography
(1962) · American Heart Journal · doi:10.1016/0002-8703(62)90323-x · Cited by 287
Vectorcardiogram synthesized from a 12-lead ECG: Superiority of the inverse Dower matrix
Edenbrandt, L., & Pahlm, O. (1988) · Journal of Electrocardiology · doi:10.1016/0022-0736(88)90113-6 · Cited by 285 · cited 1×
“One can choose between a model-based [20] and a regression-based [21] method.”
MethodMethodology of the Modular ECG Analysis System MEANS
van Herpen, G., van Bemmel, J. H., & Kors, J. A. (1990) · Methods of Information in Medicine · doi:10.1055/s-0038-1634805 · Cited by 271 · cited 4×
“All ECGs were processed by the Modular ECG Analysis System (MEANS) [17].”
BackgroundMethodInfluentialSelf-citationElectrocardiographic findings in 67,375 asymptomatic subjects
Hiss, R. G., Averill, K. H., & Lamb, L. E. (1960) · The American Journal of Cardiology · doi:10.1016/0002-9149(60)90045-x · Cited by 210 · cited 2×
“Normal values for the adult ECG have been determined in a number of studies [1–11].”
BackgroundElectrocardiographic findings in 67,375 asymptomatic subjects
Hiss, R. G., Lamb, L. E., & Allen, M. F. (1960) · The American Journal of Cardiology · doi:10.1016/0002-9149(60)90047-3 · Cited by 174
A reference data base for multilead electrocardiographic computer measurement programs
Willems, J. L., Arnaud, P., Van Bemmel, J. H., Bourdillon, P. J., Degani, R., Denis, B., Graham, I., Harms, F. M. A., Macfarlane, P. W., Mazzocca, G., et al. (1987) · Journal of the American College of Cardiology · doi:10.1016/s0735-1097(87)80136-5 · Cited by 156
RAUTAHARJU, P. M., & ZHANG, Z. (2002) · Journal of Cardiovascular Electrophysiology · doi:10.1046/j.1540-8167.2002.01211.x · Cited by 117 · cited 1×
“It is well-known that Bazett's formula overcorrects for heart rates above 60 bpm [6,27].”
BackgroundThe Utrecht Health Project: Optimization of routine healthcare data for research
Grobbee, D. E., Hoes, A. W., Verheij, T. J., Schrijvers, G., van Ameijden, E. J. C., & Numans, M. E. (2005) · European Journal of Epidemiology · doi:10.1007/s10654-004-5689-2 · Cited by 110 · cited 2×
“(3) The Utrecht Health Project (UHP).”
BackgroundSelf-citationde Jong, P. E. (2002) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/18.1.10 · Cited by 106 · cited 1×
“PREVEND is a population-based prospective cohort study to investigate the natural course of microalbuminuria and its relation to renal and cardiovascular disease in the general population [14].”
BackgroundEthnic differences in ECG amplitudes in North American white, black, and Hispanic men and women
Rautaharju, P. M., Zhou, S., & Calhoun, H. P. (1994) · Journal of Electrocardiology · doi:10.1016/s0022-0736(94)80040-5 · Cited by 102 · cited 1×
“In white and black women, an increase of R amplitudes in V5 with age was also reported before [29].”
BackgroundScherptong, R. W. C., Henkens, I. R., Man, S., le Cessie, S., Vliegen, H. W., Draisma, H. H. M., Maan, A. C., Schalij, M. J., & Swenne, C. A. (2008) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2008.07.006 · Cited by 91 · cited 2×
“In the course of their education, standard 10-second 12-lead ECGs were obtained from 787 medical students of Leiden University (Leiden, The Netherlands), who attested to be in good health [9].”
MethodSelf-citationNormal limits of the electrocardiogram in Chinese subjects
Wu, J., Kors, J. A., Rijnbeek, P. R., van Herpen, G., Zaiying, L., & Xu, C. (2002) · International Journal of Cardiology · doi:10.1016/s0167-5273(02)00248-6 · Cited by 85 · cited 1×
“published a comprehensive study of a Chinese population of 5360 men and women [5].”
BackgroundSelf-citationCortez, D., & Schlegel, T. T. (2010) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.03.010 · Cited by 75
Normal limits of the electrocardiogram in a Chinese population
Chen, C.-Y., Chiang, B. N., & Macfarlane, P. W. (1989) · Journal of Electrocardiology · doi:10.1016/0022-0736(89)90018-6 · Cited by 63 · cited 1×
“A similar trend, although less marked, had also been noted in a smaller sample of Chinese subjects [28].”
ResultT wave amplitudes in normal populations
Gambill, C. L., Wilkins, M. L., Haisty, W. K., Anderson, S. T., Maynard, C. C., Wagner, N. B., Selvester, R. H. S., & Wagner, G. S. (1995) · Journal of Electrocardiology · doi:10.1016/s0022-0736(05)80257-2 · Cited by 55 · cited 1×
“Normal values for the adult ECG have been determined in a number of studies [1–11].”
BackgroundSchreurs, C. A., Algra, A. M., Man, S., Cannegieter, S. C., van der Wall, E. E., Schalij, M. J., Kors, J. A., & Swenne, C. A. (2010) · Journal of Electrocardiology · doi:10.1016/j.jelectrocard.2010.03.009 · Cited by 55 · cited 1×
“In this article, we used the regression method, which has previously been shown to yield superior performance [21–23].”
MethodSelf-citationThe U wave in the electrocardiogram: A solution for a 100-year-old riddle
RITSEMAVANECK, H., Kors, J. A., & VANHERPEN, G. (2005) · Cardiovascular Research · doi:10.1016/j.cardiores.2005.04.010 · Cited by 47 · cited 1×
“Determination of the end of the T wave may be incommoded by inconvenient U waves and one may even propound that the U wave is an integral part of repolarization, which, therefore, is only finished at the “end of U”, the “end of T” being a mere inflectional point in the total repolarization curve [26].”
BackgroundSelf-citationAccurate automatic detection of electrode interchange in the electrocardiogram
Kors, J. A., & van Herpen, G. (2001) · The American Journal of Cardiology · doi:10.1016/s0002-9149(01)01686-1 · Cited by 46 · cited 1×
“Electrode interchanges were detected by a special feature in the computer program [16].”
Self-citationElectrocardiogram Reference Ranges Derived from a Standardized Clinical Trial Population
Dmitrienke, A. A., Sides, G. D., Winters, K. J., Kovacs, R. J., Rebhun, D. M., Bloom, J. C., Groh, W. J., & Eisenberg, P. R. (2005) · Drug Information Journal · doi:10.1177/009286150503900408 · Cited by 41 · cited 3×
“A fourth limitation is that many studies, among them the most recent ones, focus on a limited set of parameters [7,8], or even on only one single specific measurement, e.”
BackgroundInvestigative Electrocardiography in Epidemiological Studies and Clinical Trials
Rautaharju, P. M., & Rautaharju, F. (2007) · Springer eBooks · doi:10.1007/978-1-84628-481-6 · Cited by 40 · cited 1×
“Rautaharju, in his treatise of 2007 on the application of the ECG in epidemiological studies and clinical trials [12], provides very detailed tables from 11,707 individuals on intervals, amplitudes and axes, but only for the age groups 40–59 years and 60+ years.”
BackgroundStability of computer ECG amplitude measurements in the presence of noise
Zywietz, C., Willems, J. L., Arnaud, P., van Bemmel, J. H., Degani, R., & Macfarlane, P. W. (1990) · Computers and Biomedical Research · doi:10.1016/0010-4809(90)90003-u · Cited by 39 · cited 1×
“MEANS has extensively been evaluated both by its developers [17] and by others [18,19].”
BackgroundLimb leads of the electrocardiogram: Sequencing revisited
Dower, G. E., Nazzal, S. B., Bullington, D., Pahlm, O., Haistey, W. K., Marriott, H. L., & Bullington, R. H. (1990) · Clinical Cardiology · doi:10.1002/clc.4960130508 · Cited by 22 · cited 1×
“Presentation of the extremity leads in the arrangement proposed by Cabrera (aVL, I, −aVR, II, aVF, III) makes lead aVR behave like its companion leads and clarifies its logical connection to the other extremity leads [24].”
BackgroundLimb leads of the electrocardiogram: Sequencing revisited
Zatuchni, J., Dower, G. E., & Nazzal, S. B. (1990) · Clinical Cardiology · doi:10.1002/clc.4960130702 · Cited by 19 · cited 1×
“Presentation of the extremity leads in the arrangement proposed by Cabrera (aVL, I, −aVR, II, aVF, III) makes lead aVR behave like its companion leads and clarifies its logical connection to the other extremity leads [24].”
Background
Cited by
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Journal of the American College of Cardiology · doi:10.1016/j.jacc.2018.10.044 · Cited by 1,008
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Circulation · doi:10.1161/cir.0000000000000628 · Cited by 603
Kusumoto, F. M., Schoenfeld, M. H., Barrett, C., Edgerton, J. R., Ellenbogen, K. A., Gold, M. R., Goldschlager, N. F., Hamilton, R. M., Joglar, J. A., Kim, R. J., et al. (2019) · Heart Rhythm · doi:10.1016/j.hrthm.2018.10.037 · Cited by 131
Vink, A. S., Clur, S.-A. B., Wilde, A. A. M., & Blom, N. A. (2018) · Trends in Cardiovascular Medicine · doi:10.1016/j.tcm.2017.07.012 · Cited by 91
A Cardiac Early Warning System with Multi Channel SCG and ECG Monitoring for Mobile Health
Sahoo, P., Thakkar, H., & Lee, M.-Y. (2017) · Sensors · doi:10.3390/s17040711 · Cited by 81
“It is observed that the amplitude A P wave , A QRS wave and duration D P wave , D QRS wave of P and QRS wave range in between certain fixed values for a healthy person as shown in Table 1 [46,47].”
Background
Metadata
- Authors
- Rijnbeek, P. R., van Herpen, G., Bots, M. L., Man, S., Verweij, N., Hofman, A., Hillege, H., Numans, M. E., Swenne, C. A., Witteman, J. C. M., & Kors, J. A.
- Venue
- Journal of Electrocardiology
- Publisher
- Elsevier BV
- Published
- 2014-11
- Volume
- 47
- Issue
- 6
- Pages
- 914-921
- ISSN
- 0022-0736 (ISSN-L)
- OpenAlex
- W2118549020
- Cited by
- 192
- References
- 29
- FWCI
- 8.63
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.