Consensus for experimental design in electromyography (CEDE) project: Electrode selection matrix

Open access
Besomi, Manuela, Hodges, Paul W., Van Dieën, Jaap, Carson, Richard G., Clancy, Edward A., Disselhorst-Klug, Catherine, Holobar, Aleš, Hug, François, Kiernan, Matthew C., Lowery, Madeleine, McGill, Kevin, Merletti, Roberto, Perreault, Eric, Søgaard, Karen, Tucker, Kylie, Besier, Thor, Enoka, Roger, Falla, Deborah, Farina, Dario, Gandevia, Simon, Rothwell, John C., Vicenzino, Bill, Wrigley, Tim · 2019 · Journal of Electromyography and Kinesiology
Cited by 165

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The Consensus for Experimental Design in Electromyography (CEDE) project is an international initiative which aims to guide decision-making in recording, analysis, and interpretation of electromyographic (EMG) data. The quality of the EMG recording, and validity of its interpretation depend on many characteristics of the recording set-up and analysis procedures. Different electrode types (i.e., surface and intramuscular) will influence the recorded signal and its interpretation. This report presents a matrix to consider the best electrode type selection for recording EMG, and the process undertaken to achieve consensus. Four electrode types were considered: (1) conventional surface electrode, (2) surface matrix or array electrode, (3) fine-wire electrode, and (4) needle electrode. General features, pros, and cons of each electrode type are presented first. This information is followed by recommendations for specific types of muscles, the information that can be estimated, the typical representativeness of the recording and the types of contractions for which the electrode is best suited. This matrix is intended to help researchers when selecting and reporting the electrode type in EMG studies.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jelekin.2019.07.008

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Research works printed but not linked: 22

  1. Afsharipour, 2019, Two-dimensional surface EMG: the effects of electrode size, interelectrode distance and image truncation, Biomed. Sig. Process. Contr., 49, 298, 10.1016/j.bspc.2018.12.001 · DOI
  2. Disselhorst-Klug, 2009, Surface electromyography and muscle force: limits in sEMG-force relationship and new approaches for applications, Clin. Biomech. (Bristol, Avon), 24, 225, 10.1016/j.clinbiomech.2008.08.003 · DOI · Paper page
  3. Doğan-Aslan, 2012, The effect of electromyographic biofeedback treatment in improving upper extremity functioning of patients with hemiplegic stroke, J. Stroke Cerebrovasc. Dis., 21, 187, 10.1016/j.jstrokecerebrovasdis.2010.06.006 · DOI
  4. Farina, 2014, The extraction of neural strategies from the surface EMG: an update, J. Appl. Physiol., 117, 1215, 10.1152/japplphysiol.00162.2014 · DOI · Paper page
  5. Ferrari, 2018, Ultraconformable temporary tattoo electrodes for electrophysiology, Adv. Sci., 5, 1700771, 10.1002/advs.201700771 · DOI · Paper page
  6. Hodges, 2019, Editorial: consensus for experimental design in electromyography (CEDE) project [under review], J. Electromyogr. Kinesiol.
  7. Inzelberg, 2018, A wearable high-resolution facial electromyography for long term recordings in freely behaving humans, Scient. Rep., 8, 2058, 10.1038/s41598-018-20567-y · DOI
  8. Keshwani, 2015, State of the art review: Intravaginal probes for recording electromyography from the pelvic floor muscles, Neurourol. Urodyn., 34, 104, 10.1002/nau.22529 · DOI
  9. Kuiken, 2003, The effect of subcutaneous fat on myoelectric signal amplitude and cross-talk, Prosthet. Orthot. Int., 27, 48, 10.3109/03093640309167976 · DOI · Paper page
  10. Lichter, 2010, Rechargeable wireless EMG sensor for prosthetic control, Conf. Proc. IEEE Eng. Med. Biol. Soc., 2010, 5074
  11. Liu, 2017, High-adhesion stretchable electrodes based on nanopile interlocking, Adv. Mater., 29, 1603382, 10.1002/adma.201603382 · DOI · Paper page
  12. Merletti, R. Applications in Proctology and Obstetrics. In Merletti, R., Farina. D., editors. Surface Electromyography: Physiology, Engineering, and Applications. 2016, Chapter 14: pp.392-407. 10.1002/9781119082934.ch14. · doi:10.1002/9781119082934.ch14
  13. Merletti, 2009, Technology and instrumentation for detection and conditioning of the surface electromyographic signal: State of the art, Clin. Biomech., 24, 122, 10.1016/j.clinbiomech.2008.08.006 · DOI · Paper page
  14. Merletti, 1887, Analysis of intramuscular electromyogram signals, Phil. Trans. R. Soc. A., 2009, 357
  15. Merlo, A., Campanini, I. Applications in Movement and Gait Analysis. In: Merletti, R., Farina, D., editors. Surface Electromyography: Physiology, Engineering, and Applications. 2016, Chapter 16: p.440-59. 10.1002/9781119082934. · DOI
  16. Mesin, 2009, Automatic localisation of innervation zones: a simulation study of the external anal sphincter, J. Electromyogr. Kinesiol., 19, e413, 10.1016/j.jelekin.2009.02.002 · DOI
  17. Mesin, 2009, Surface EMG: the issue of electrode location, J. Electromyogr. Kinesiol., 19, 719, 10.1016/j.jelekin.2008.07.006 · DOI · Paper page
  18. Mu, 2010, Sihler's whole mount nerve staining technique: a review, Biotech. Histochem., 85, 19, 10.3109/10520290903048384 · DOI
  19. Parker, 2006, Myoelectric signal processing for control of powered limb prostheses, J. Electromyogr. Kinesiol., 16, 541, 10.1016/j.jelekin.2006.08.006 · DOI · Paper page
  20. Staudenmann, 2010, Methodological aspects of SEMG recordings for force estimation–a tutorial and review, J. Electromyogr. Kinesiol., 20, 375, 10.1016/j.jelekin.2009.08.005 · DOI · Paper page
  21. Turker, 1993, Electromyography: some methodological problems and issues, Phys. Ther., 73, 698, 10.1093/ptj/73.10.698 · DOI · Paper page
  22. Waggoner, 2016, Is there a consensus on consensus methodology? descriptions and recommendations for future consensus research, Acad. Med., 91, 663, 10.1097/ACM.0000000000001092 · DOI · Paper page

Cited by

See all 165

Metadata

Authors
Besomi, M., Hodges, P. W., Van Dieën, J., Carson, R. G., Clancy, E. A., Disselhorst-Klug, C., Holobar, A., Hug, F., Kiernan, M. C., Lowery, M., McGill, K., Merletti, R., Perreault, E., Søgaard, K., Tucker, K., Besier, T., Enoka, R., Falla, D., Farina, D., Gandevia, S., Rothwell, J. C., Vicenzino, B., & Wrigley, T.
Venue
Journal of Electromyography and Kinesiology
Publisher
Elsevier BV
Published
2019-10
Volume
48
Pages
128-144
ISSN
1050-6411 (ISSN-L)
OpenAlex
W2964250412
Cited by
165
References
4
FWCI
4.73
Type
journal article
Language
en
Open access
bronze
Licence
  • www.elsevier.com/tdm/userlicense/1.0/ (tdm)
  • www.elsevier.com/legal/tdmrep-license (tdm)
Funders
  • Javna Agencija za Raziskovalno Dejavnost RS
  • National Health and Medical Research Council

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.