CoChat

Calibration and validation of a novel passive sampling device for the time integrative monitoring of per- and polyfluoroalkyl substances (PFASs) and precursors in contaminated groundwater

Kaserzon, Sarit L., Vijayasarathy, Soumini, Bräunig, Jennifer, Mueller, Linus, Hawker, Darryl W., Thomas, Kevin V., Mueller, Jochen F. · 2019 · Journal of Hazardous Materials
Cited by 72

The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.

Abstract

Per-and polyfluoroalkyl substances (PFASs) as key components in aqueous film forming foams (AFFF) have led to growing incidences of environmental contamination. The aim of this study was to investigate a novel diffusion based passive sampling device comprising of microporous polyethylene (PE) for the long-term time-integrative monitoring of PFASs in groundwater systems. PE passive samplers (PEs) were deployed for 83 d and calibrated at five AFFF impacted groundwater sites representing different PFASs concentration levels (ΣPFAS 0.001 to 0.1 ng mL-1). Grab samples were collected simultaneously. Linear accumulation of 12 PFASs (r2 ≥ 0.84) were observed in the PEs over 83 d and PFASs sampling rates were 2-5 mL d-1. Estimated mean half-times to equilibrium for PFASs ranged between 122 and 490 d. A separate validation study compared PEs and grab sampling during a 93 d field deployment, at seven groundwater sites near a fire fighting training ground. Seventeen PFASs were detected in PEs and fifteen in grab samples. PEs showed higher sensitivity for precursors (i.e. 4:2 FTS and FOSA). Time-weighted-average water concentrations across all validation sites for all PFASs determined from PEs were strongly correlated (r2 = 0.98) with grab samples, (within range 0.3-60 ng mL-1 PFOS). Results represent the first application of passive sampling technology for the quantitative assessment of PFASs in groundwater systems.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jhazmat.2018.12.010

Cites

8 of 8 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 8 references

Cited by

See all 72

Metadata

Authors
Kaserzon, S. L., Vijayasarathy, S., Bräunig, J., Mueller, L., Hawker, D. W., Thomas, K. V., & Mueller, J. F.
Venue
Journal of Hazardous Materials
Publisher
Elsevier BV
Published
2019-03
Volume
366
Pages
423-431
ISSN
0304-3894 (ISSN-L)
OpenAlex
W2905103640
Cited by
72
References
8
FWCI
1.72
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Calibration and validation of a novel passive sampling device for the time integrative monitoring of per- and polyfluoroalkyl substances (PFASs) and precursors in contaminated groundwater. https://app.cochat.ai/papers/10.1016/j.jhazmat.2018.12.010
The paper
Kaserzon, S. L., Vijayasarathy, S., Bräunig, J., Mueller, L., Hawker, D. W., Thomas, K. V., & Mueller, J. F. (2019). Calibration and validation of a novel passive sampling device for the time integrative monitoring of per- and polyfluoroalkyl substances (PFASs) and precursors in contaminated groundwater. Journal of Hazardous Materials. https://doi.org/10.1016/j.jhazmat.2018.12.010

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.