Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 219

The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.

Mechanical evaluation of bacterial nanocellulose as an implant material for ear cartilage replacement

Open access
Nimeskern, Luc, Martínez Ávila, Héctor, Sundberg, Johan, Gatenholm, Paul, Müller, Ralph, Stok, Kathryn S.·2013·Journal of the Mechanical Behavior of Biomedical Materials

Abstract

Bacterial nanocellulose (BNC) is a novel non-degradable biocompatible material that promotes chondrocyte adhesion and proliferation. In this work, its potential use in ear cartilage tissue engineering (TE) is investigated. Firstly, the mechanical properties of native ear cartilage are measured in order to set a preliminary benchmark for ear cartilage replacement materials. Secondly, the capacity of BNC to match these requirements is assessed. Finally, a biofabrication process to produce patient-specific BNC auricular implants is demonstrated. BNC samples (n=78) with varying cellulose content (2.5-15%) were compared using stress-relaxation indentation with human ear cartilage (n=17, from 4 males, aged 49-93 years old). Additionally, an auricle from a volunteer was scanned using a 3T MRI with a spoiled gradient-echo sequence. A negative ear mold was produced from the MRI data in order to investigate if an ear-shaped BNC prototype could be produced from this mold. The results show that the instantaneous modulus Ein, equilibrium modulus Eeq, and maximum stress σmax of the BNC samples are correlated to effective cellulose content. Despite significantly different relaxation kinetics, the Ein, Eeq and σmax of BNC at 14% effective cellulose content reached values equivalent to ear cartilage (for Eeq, BNC: 2.4±0.4MPa and ear cartilage: 3.3±1.3MPa). Additionally, this work shows that BNC can be fabricated into patient-specific auricular shapes. In conclusion, BNC has the capability to reach mechanical properties of relevance for ear cartilage replacement, and can be produced in patient-specific ear shapes.

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jmbbm.2013.03.005

Cites

1 of 1 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 1 references

Cited by

See all 219

Metadata

Authors
Nimeskern, L., Martínez Ávila, H., Sundberg, J., Gatenholm, P., Müller, R., & Stok, K. S.
Venue
Journal of the Mechanical Behavior of Biomedical Materials
Publisher
Elsevier BV
Published
2013-06
Volume
22
Pages
12-21
ISSN
1751-6161 (ISSN-L)
OpenAlex
W2047876202
Cited by
219
References
1
FWCI
6.47
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical evaluation of bacterial nanocellulose as an implant material for ear cartilage replacement. https://app.cochat.ai/papers/10.1016/j.jmbbm.2013.03.005
The paper
Nimeskern, L., Martínez Ávila, H., Sundberg, J., Gatenholm, P., Müller, R., & Stok, K. S. (2013). Mechanical evaluation of bacterial nanocellulose as an implant material for ear cartilage replacement. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2013.03.005

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.