CoChat

Mechanical behavior of bioactive poly(ethylene glycol) diacrylate matrices for biomedical application

Della Sala, Francesca, Biondi, Marco, Guarnieri, Daniela, Borzacchiello, Assunta, Ambrosio, Luigi, Mayol, Laura · 2020 · Journal of the Mechanical Behavior of Biomedical Materials
Cited by 76

The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.

Abstract

The biomedical applications of physically entangled polymeric hydrogels are generally limited due to their weak mechanical properties, rapid swelling and dissolution in physiologically relevant environment. Chemical crosslinking helps stabilizing hydrogel structure and enhancing mechanical properties, thereby allowing a higher stability in phisiological environment. In this context, it is known that the mechanical properties of the hydrogel are affected by both the molecular weight (MW) of the starting polymer and the concentration of the crosslinker. Here, our aim was to assess the influence of polymer MW and concentration in the precursor solution on the mechanical features of the final hydrogel and their influence on cells-material interaction. In detail, 3D synthetic matrices based on poly(ethylene glycol) diacrylate (PEGDA) at two molecular weights (PEG 700 and PEG 3400) and at three different concentrations (10, 20, 40 w/v %), which were photopolymerized using darocour as an initiator, were studied. Then, infrared and swelling analyses, along with a comprehensive mechanical characterization of the obtained hydrogels (i.e. oscillatory shear and confined compression tests), were performed. Finally, to evaluate the influence of the mechanical features on the biological behaviour, the hydrogels were characterized in terms of cell adhesion percentage and cell viability after functionalizing the substrates with RGD peptide at three different concentrations. Results have demonstrated that both the Young's modulus (E) in compression and the elastic modulus (G') in shear of the hydrogels increase with increasing polymer precursor concentration. E decreased as MW increased, and the differences are more relevant for more concentrated hydrogels. On the contrary, G' appears to increase with increasing PEGDA MW and in particular for the lowest polymer precursor concentration. The biological results have demonstrated that cells cultured for longer times seem to prefer PEG 3400 hydrogels with a larger mesh size structure that posses higher viscoelastic properties in shear.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.jmbbm.2020.103885

Cites

4 of 4 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 4 references

Cited by

See all 76

Metadata

Authors
Della Sala, F., Biondi, M., Guarnieri, D., Borzacchiello, A., Ambrosio, L., & Mayol, L.
Venue
Journal of the Mechanical Behavior of Biomedical Materials
Publisher
Elsevier BV
Published
2020-10
Volume
110
Pages
103885
ISSN
1751-6161 (ISSN-L)
OpenAlex
W3033458160
Cited by
76
References
4
FWCI
2.34
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Mechanical behavior of bioactive poly(ethylene glycol) diacrylate matrices for biomedical application. https://app.cochat.ai/papers/10.1016/j.jmbbm.2020.103885
The paper
Della Sala, F., Biondi, M., Guarnieri, D., Borzacchiello, A., Ambrosio, L., & Mayol, L. (2020). Mechanical behavior of bioactive poly(ethylene glycol) diacrylate matrices for biomedical application. Journal of the Mechanical Behavior of Biomedical Materials. https://doi.org/10.1016/j.jmbbm.2020.103885

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.