Hydration and swelling of dry polymers for wet adhesion
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Whereas two dry surfaces can adhere to each other upon contact, it is challenging to form adhesion between two wet surfaces separated by interfacial water. A commonly used strategy for adhesion of wet surfaces such as wet tissues is to let adhesives such as monomers, macromers, polymers, and particles diffuse across the interfacial water and subsequently form physical and/or chemical crosslinking with the surfaces. In contrast, a recently developed strategy for wet adhesion is to make adhesives such as dry polymer networks quickly absorb the interfacial water and then crosslink with the surfaces. Since the absorption of interfacial water requires hydration and swelling of the dry polymer networks, understanding the physics and mechanics of this concurrent hydration and swelling process will potentially facilitate the design of future adhesives for wet adhesion. In this paper, we present a combined theoretical and experimental study on dry polymer networks that absorb interfacial water for wet adhesion. We observe that the absorption of interfacial water creates a sharp hydration front in the initially dry polymer network, where the hydrated part swells by further absorption of water and the un-hydrated part maintains in the dry state. We develop a quantitative model for the coupled hydration and swelling of polymer networks governed by the Case-I diffusion and validate the model with experimental data. We finally present a guideline for the design of dry polymer networks to achieve fast, stable, and tough adhesion with wet surfaces.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Rubinstein, M., & Colby, R. H. (2003) · doi:10.1093/oso/9780198520597.001.0001 · Cited by 5,686
A theory of the linear viscoelastic properties of dilute solutions of coiling polymers
Rouse, P. E. (1953) · The Journal of Chemical Physics · doi:10.1063/1.1699180 · Cited by 4,203
On Physically Similar Systems; Illustrations of the Use of Dimensional Equations
Buckingham, E. (1914) · Physical Review · doi:10.1103/physrev.4.345 · Cited by 3,588
Mussel-Inspired Adhesives and Coatings
Lee, B. P., Messersmith, P. B., Israelachvili, J. N., & Waite, J. H. (2011) · Annual Review of Materials Research · doi:10.1146/annurev-matsci-062910-100429 · Cited by 1,668
Skin-inspired hydrogel–elastomer hybrids with robust interfaces and functional microstructures
Yuk, H., Zhang, T., Parada, G. A., Liu, X., & Zhao, X. (2016) · Nature Communications · doi:10.1038/ncomms12028 · Cited by 1,035
Self-citationLooking Beyond Fibrillar Features to Scale Gecko‐Like Adhesion
Bartlett, M. D., Croll, A. B., King, D. R., Paret, B. M., Irschick, D. J., & Crosby, A. J. (2012) · Advanced Materials · doi:10.1002/adma.201104191 · Cited by 317
Cited by
Nam, S., & Mooney, D. (2021) · Chemical Reviews · doi:10.1021/acs.chemrev.0c00798 · Cited by 764
Electrical bioadhesive interface for bioelectronics
Deng, J., Yuk, H., Wu, J., Varela, C. E., Chen, X., Roche, E. T., Guo, C. F., & Zhao, X. (2021) · Nature Materials · doi:10.1038/s41563-020-00814-2 · Cited by 727
Self-citationRecent advances in wet adhesives: Adhesion mechanism, design principle and applications
Cui, C., & Liu, W. (2021) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2021.101388 · Cited by 557
Instant tough bioadhesive with triggerable benign detachment
Chen, X., Yuk, H., Wu, J., Nabzdyk, C. S., & Zhao, X. (2020) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2006389117 · Cited by 391
Self-citationRapid and coagulation-independent haemostatic sealing by a paste inspired by barnacle glue
Yuk, H., Wu, J., Sarrafian, T. L., Mao, X., Varela, C. E., Roche, E. T., Griffiths, L. G., Nabzdyk, C. S., & Zhao, X. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-021-00769-y · Cited by 345
Self-citationA Janus Hydrogel Wet Adhesive for Internal Tissue Repair and Anti‐Postoperative Adhesion
Cui, C., Wu, T., Chen, X., Liu, Y., Li, Y., Xu, Z., Fan, C., & Liu, W. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202005689 · Cited by 344
A strain-programmed patch for the healing of diabetic wounds
Theocharidis, G., Yuk, H., Roh, H., Wang, L., Mezghani, I., Wu, J., Kafanas, A., Contreras, M., Sumpio, B., Li, Z., et al. (2022) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00905-2 · Cited by 337
Self-citationStrategies for body-conformable electronics
Liu, S., Rao, Y., Jang, H., Tan, P., & Lu, N. (2022) · Matter · doi:10.1016/j.matt.2022.02.006 · Cited by 306
An off-the-shelf bioadhesive patch for sutureless repair of gastrointestinal defects
Wu, J., Yuk, H., Sarrafian, T. L., Guo, C. F., Griffiths, L. G., Nabzdyk, C. S., & Zhao, X. (2022) · Science Translational Medicine · doi:10.1126/scitranslmed.abh2857 · Cited by 229
Self-citationBioadhesive Technology Platforms
Wu, S. J., & Zhao, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00380 · Cited by 218
Self-citationLiu, J., Song, J., Zeng, L., & Hu, B. (2024) · International Journal of Molecular Sciences · doi:10.3390/ijms25147994 · Cited by 28
“Consequently, interfacial adhesion is disrupted [9,10].”
Metadata
- Authors
- Mao, X., Yuk, H., & Zhao, X.
- Venue
- Journal of the Mechanics and Physics of Solids
- Publisher
- Elsevier BV
- Published
- 2020-04
- Volume
- 137
- Pages
- 103863
- ISSN
- 0022-5096 (ISSN-L)
- OpenAlex
- W2997693043
- Cited by
- 86
- References
- 6
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.