Gradient waveform design for tensor-valued encoding in diffusion MRI
Open accessThe DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Abstract
Diffusion encoding along multiple spatial directions per signal acquisition can be described in terms of a b-tensor. The benefit of tensor-valued diffusion encoding is that it unlocks the 'shape of the b-tensor' as a new encoding dimension. By modulating the b-tensor shape, we can control the sensitivity to microscopic diffusion anisotropy which can be used as a contrast mechanism; a feature that is inaccessible by conventional diffusion encoding. Since imaging methods based on tensor-valued diffusion encoding are finding an increasing number of applications we are prompted to highlight the challenge of designing the optimal gradient waveforms for any given application. In this review, we first establish the basic design objectives in creating field gradient waveforms for tensor-valued diffusion MRI. We also survey additional design considerations related to limitations imposed by hardware and physiology, potential confounding effects that cannot be captured by the b-tensor, and artifacts related to the diffusion encoding waveform. Throughout, we discuss the expected compromises and tradeoffs with an aim to establish a more complete understanding of gradient waveform design and its impact on accurate measurements and interpretations of data.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Spin Diffusion Measurements: Spin Echoes in the Presence of a Time-Dependent Field Gradient
Stejskal, E. O., & Tanner, J. E. (1965) · The Journal of Chemical Physics · doi:10.1063/1.1695690 · Cited by 8,286
MR diffusion tensor spectroscopy and imaging
Basser, P. J., Mattiello, J., & LeBihan, D. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80775-1 · Cited by 5,970 · cited 1×
“Naturally, these metrics are analogous to rotation invariant metrics derived from the diffusion tensor (Kingsley, 2006; Basser et al., 1994; Westin et al., 2002).”
The basis of anisotropic water diffusion in the nervous system—A technical review.
Beaulieu, C. (2002) · NMR in Biomedicine · doi:10.1002/nbm.782 · Cited by 4,628 · cited 2×
“For example, the apparent diffusivity is reduced as tissue density increases (Chen et al., 2013) and may be anisotropic if the structures allow faster diffusion along a given direction (Stanisz et al., 1997; Beaulieu, 2002).”
Le Bihan, D., Breton, E., Lallemand, D., Grenier, P., Cabanis, E., & Laval-Jeantet, M. (1986) · Radiology · doi:10.1148/radiology.161.2.3763909 · Cited by 3,912
Plasticity in gray and white: neuroimaging changes in brain structure during learning
Zatorre, R. J., Fields, R. D., & Johansen-Berg, H. (2012) · Nature Neuroscience · doi:10.1038/nn.3045 · Cited by 1,685 · cited 1×
“, 2019), learning (Zatorre et al., 2012; Thomas and Baker, 2013), white matter morphology and connectivity (Jones, 2008; Tournier, 2019), development of cancers (Padhani et al.”
Moseley, M. E., Cohen, Y., Mintorovitch, J., Chileuitt, L., Shimizu, H., Kucharczyk, J., Wendland, M. F., & Weinstein, P. R. (1990) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910140218 · Cited by 1,644
Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation
Novikov, D. S., Fieremans, E., Jespersen, S. N., & Kiselev, V. G. (2019) · NMR in Biomedicine · doi:10.1002/nbm.3998 · Cited by 581
Pushing the limits of in vivo diffusion MRI for the Human Connectome Project
Setsompop, K., Kimmlingen, R., Eberlein, E., Witzel, T., Cohen-Adad, J., McNab, J. A., Keil, B., Tisdall, M. D., Hoecht, P., Dietz, P., et al. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.078 · Cited by 545 · cited 1×
“F. Szczepankiewicz et al. Journal of Neuroscience Methods xxx (xxxx) xxx (Setsompop et al., 2013) and are instrumental for exploring the frontier of dMRI (Jones et al., 2018).”
BackgroundAn analytical model of restricted diffusion in bovine optic nerve
Stanisz, G. J., Wright, G. A., Henkelman, R. M., & Szafer, A. (1997) · Magnetic Resonance in Medicine · doi:10.1002/mrm.1910370115 · Cited by 501 · cited 1×
“, 2013) and may be anisotropic if the structures allow faster diffusion along a given direction (Stanisz et al., 1997; Beaulieu, 2002).”
Applications of diffusion‐weighted and diffusion tensor MRI to white matter diseases – a review
Horsfield, M. A., & Jones, D. K. (2002) · NMR in Biomedicine · doi:10.1002/nbm.787 · Cited by 468
Cited by
Lampinen, B., Szczepankiewicz, F., Lätt, J., Knutsson, L., Mårtensson, J., Björkman-Burtscher, I. M., van Westen, D., Sundgren, P. C., Ståhlberg, F., & Nilsson, M. (2023) · NeuroImage · doi:10.1016/j.neuroimage.2023.120338 · Cited by 38
Self-citationEngineering clinical translation of OGSE diffusion MRI
Zhu, A., Michael, E. S., Li, H., Sprenger, T., Hua, Y., Lee, S., Yeo, D. T. B., McNab, J. A., Hennel, F., Fieremans, E., et al. (2025) · Magnetic Resonance in Medicine · doi:10.1002/mrm.30510 · Cited by 13
Mapping grey and white matter activity in the human brain with isotropic ADC-fMRI
Spencer, A. P. C., Nguyen-Duc, J., de Riedmatten, I., Szczepankiewicz, F., & Jelescu, I. O. (2025) · Nature Communications · doi:10.1038/s41467-025-60357-5 · Cited by 12
Self-citation
Metadata
- Authors
- Szczepankiewicz, F., Westin, C.-F., & Nilsson, M.
- Venue
- Journal of Neuroscience Methods
- Publisher
- Elsevier BV
- Published
- 2021-01
- Volume
- 348
- Pages
- 109007
- ISSN
- 0165-0270 (ISSN-L)
- OpenAlex
- W3042258507
- Cited by
- 98
- References
- 23
- FWCI
- 5.60
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Gradient waveform design for tensor-valued encoding in diffusion MRI. https://app.cochat.ai/papers/10.1016/j.jneumeth.2020.109007
- The paper
- Szczepankiewicz, F., Westin, C.-F., & Nilsson, M. (2021). Gradient waveform design for tensor-valued encoding in diffusion MRI. Journal of Neuroscience Methods. https://doi.org/10.1016/j.jneumeth.2020.109007
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.