The DOI matches its Crossref record; 33 of the 33 references it cites were found in a registry or an index.
Development of a microphysiological model of human kidney proximal tubule function
Open accessAbstract
The kidney proximal tubule is the primary site in the nephron for excretion of waste products through a combination of active uptake and secretory processes, and is also a primary target of drug-induced nephrotoxicity. Here, we describe the development and functional characterization of a 3-dimensional flow-directed human kidney proximal tubule microphysiological system. The system replicates the polarity of the proximal tubule, expresses appropriate marker proteins, exhibits biochemical and synthetic activities, as well as secretory and reabsorptive processes associated with proximal tubule function in vivo. This microphysiological system can serve as an ideal platform for ex vivo modeling of renal drug clearance and drug-induced nephrotoxicity. Additionally, this novel system can be used for preclinical screening of new chemical compounds prior to initiating human clinical trials.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Understanding the Warburg Effect: The Metabolic Requirements of Cell Proliferation
Vander Heiden, M. G., Cantley, L. C., & Thompson, C. B. (2009) · Science · doi:10.1126/science.1160809 · Cited by 16,197
Matrix elasticity directs stem cell lineage specification
Engler, A. J., Sen, S., Sweeney, H. L., & Discher, D. E. (2006) · Cell · doi:10.1016/j.cell.2006.06.044 · Cited by 13,915
Tissue Cells Feel and Respond to the Stiffness of Their Substrate
Discher, D. E., Janmey, P., & Wang, Y.-L. (2005) · Science · doi:10.1126/science.1116995 · Cited by 6,382
Maschmeyer, I., Lorenz, A. K., Schimek, K., Hasenberg, T., Ramme, A. P., Hübner, J., Lindner, M., Drewell, C., Bauer, S., Thomas, A., et al. (2015) · Lab on a Chip · doi:10.1039/c5lc00392j · Cited by 861
Human kidney proximal tubule-on-a-chip for drug transport and nephrotoxicity assessment
Jang, K.-J., Mehr, A. P., Hamilton, G. A., McPartlin, L. A., Chung, S., Suh, K.-Y., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40049b · Cited by 849
Ichimura, T., Asseldonk, E. J. P. V., Humphreys, B. D., Gunaratnam, L., Duffield, J. S., & Bonventre, J. V. (2008) · Journal of Clinical Investigation · doi:10.1172/jci34487 · Cited by 765
Micropatterning as a tool to decipher cell morphogenesis and functions
Théry, M. (2010) · Journal of Cell Science · doi:10.1242/jcs.075150 · Cited by 730 · cited 1×
“It has become increasingly evident that the composition (23), microtopography (24, 25), and rigidity/elasticity (26, 27) of the ECM substrate on which a cell adheres can dictate the cells’ morphology, phenotype, proliferation, and even fate.”
SGLT2 Mediates Glucose Reabsorption in the Early Proximal Tubule
Vallon, V., Platt, K. A., Cunard, R., Schroth, J., Whaley, J., Thomson, S. C., Koepsell, H., & Rieg, T. (2011) · Journal of the American Society of Nephrology · doi:10.1681/asn.2010030246 · Cited by 563
Brenner and Rector's the Kidney
Brenner, B. M. (2003) · Medical Entomology and Zoology · Cited by 561
Cellular and molecular aspects of drug transport in the kidney
Inui, K.-I., Masuda, S., & Saito, H. (2000) · Kidney International · doi:10.1046/j.1523-1755.2000.00251.x · Cited by 450
Cited by
Organs-on-chips: into the next decade
Low, L. A., Mummery, C., Berridge, B. R., Austin, C. P., & Tagle, D. A. (2021) · Nature Reviews Drug Discovery · doi:10.1038/s41573-020-0079-3 · Cited by 1,029
Advances in organ-on-a-chip engineering
Zhang, B., Korolj, A., Lai, B. F. L., & Radisic, M. (2018) · Nature Reviews Materials · doi:10.1038/s41578-018-0034-7 · Cited by 1,017
Interconnected Microphysiological Systems for Quantitative Biology and Pharmacology Studies
Edington, C. D., Chen, W. L. K., Geishecker, E., Kassis, T., Soenksen, L. R., Bhushan, B. M., Freake, D., Kirschner, J., Maass, C., Tsamandouras, N., et al. (2018) · Scientific Reports · doi:10.1038/s41598-018-22749-0 · Cited by 487
Organ-on-a-chip devices advance to market
Zhang, B., & Radisic, M. (2017) · Lab on a Chip · doi:10.1039/c6lc01554a · Cited by 437
Renal reabsorption in 3D vascularized proximal tubule models
Lin, N. Y. C., Homan, K. A., Robinson, S. S., Kolesky, D. B., Duarte, N., Moisan, A., & Lewis, J. A. (2019) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1815208116 · Cited by 358
Organ-on-a-chip platforms: a convergence of advanced materials, cells, and microscale technologies
Ahadian, S., Civitarese, R., Bannerman, D., Mohammadi, M. H., Lu, R., Wang, E., Davenport‐Huyer, L., Lai, B., Zhang, B., Zhao, Y., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700506 · Cited by 315
Recent advances in microfluidic technologies for cell-to-cell interaction studies
Rothbauer, M., Zirath, H., & Ertl, P. (2018) · Lab on a Chip · doi:10.1039/c7lc00815e · Cited by 277
Vernetti, L., Gough, A., Baetz, N., Blutt, S., Broughman, J. R., Brown, J. A., Foulke-Abel, J., Hasan, N., In, J., Kelly, E., et al. (2017) · Scientific Reports · doi:10.1038/srep42296 · Cited by 271
Self-citationPrantil-Baun, R., Novak, R., Das, D., Somayaji, M. R., Przekwas, A., & Ingber, D. E. (2018) · Annual Review of Pharmacology and Toxicology · doi:10.1146/annurev-pharmtox-010716-104748 · Cited by 176
Fowler, S., Chen, W. L. K., Duignan, D. B., Gupta, A., Hariparsad, N., Kenny, J. R., Lai, W. G., Liras, J., Phillips, J. A., & Gan, J. (2020) · Lab on a Chip · doi:10.1039/c9lc00857h · Cited by 109
A 3D human renal cell carcinoma-on-a-chip for the study of tumor angiogenesis
Miller, C. P., Tsuchida, C., Zheng, Y., Himmelfarb, J., & Akilesh, S. (2018) · Neoplasia · doi:10.1016/j.neo.2018.02.011 · Cited by 105
Self-citationInVADE: integrated vasculature for assessing dynamic events
Lai, B. F. L., Huyer, L. D., Lu, R. X. Z., Drecun, S., Radisic, M., & Zhang, B. (2017) · Advanced Functional Materials · doi:10.1002/adfm.201703524 · Cited by 97
Kidney Organoids as Disease Models: Strengths, Weaknesses and Perspectives
Romero-Guevara, R., Ioannides, A., & Xinaris, C. (2020) · Frontiers in Physiology · doi:10.3389/fphys.2020.563981 · Cited by 65
Chang, S.-Y., Voellinger, J. L., Van Ness, K. P., Chapron, B., Shaffer, R. M., Neumann, T., White, C. C., Kavanagh, T. J., Kelly, E. J., & Eaton, D. L. (2017) · Toxicology in Vitro · doi:10.1016/j.tiv.2017.01.007 · Cited by 49
Self-citationKimura, H., Nakamura, H., Goto, T., Uchida, W., Uozumi, T., Nishizawa, D., Shinha, K., Sakagami, J., & Doi, K. (2024) · Lab on a Chip · doi:10.1039/d3lc00934c · Cited by 20
Miller, C. P., Fung, M., Jaeger-Ruckstuhl, C. A., Xu, Y., Warren, E. H., Akilesh, S., & Tykodi, S. S. (2023) · Neoplasia · doi:10.1016/j.neo.2023.100948 · Cited by 19
Metadata
- Authors
- Weber, E. J., Chapron, A., Chapron, B. D., Voellinger, J. L., Lidberg, K. A., Yeung, C. K., Wang, Z., Yamaura, Y., Hailey, D. W., Neumann, T., Shen, D. D., Thummel, K. E., Muczynski, K. A., Himmelfarb, J., & Kelly, E. J.
- Venue
- Kidney International
- Publisher
- Elsevier BV
- Published
- 2016-09
- Volume
- 90
- Issue
- 3
- Pages
- 627-637
- ISSN
- 0085-2538 (ISSN-L)
- OpenAlex
- W2505765959
- Cited by
- 272
- References
- 33
- FWCI
- 13.22
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.