Developing the Surveillance Algorithm for Detection of Failure to Recognize and Treat Severe Sepsis
Open accessThe DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
Objective: To develop and test an automated surveillance algorithm (sepsis “sniffer”) for the detection of severe sepsis and monitoring failure to recognize and treat severe sepsis in a timely manner. Patients and Methods: We conducted an observational diagnostic performance study using independent derivation and validation cohorts from an electronic medical record database of the medical intensive care unit (ICU) of a tertiary referral center. All patients aged 18 years and older who were admitted to the medical ICU from January 1 through March 31, 2013 (N=587), were included. The criterion standard for severe sepsis/septic shock was manual review by 2 trained reviewers with a third superreviewer for cases of interobserver disagreement. Critical appraisal of false-positive and false-negative alerts, along with recursive data partitioning, was performed for algorithm optimization. Results: An algorithm based on criteria for suspicion of infection, systemic inflammatory response syndrome, organ hypoperfusion and dysfunction, and shock had a sensitivity of 80% and a specificity of 96% when applied to the validation cohort. In order, low systolic blood pressure, systemic inflammatory response syndrome positivity, and suspicion of infection were determined through recursive data partitioning to be of greatest predictive value. Lastly, 117 alert-positive patients (68% of the 171 patients with severe sepsis) had a delay in recognition and treatment, defined as no lactate and central venous pressure measurement within 2 hours of the alert. Conclusion: The optimized sniffer accurately identified patients with severe sepsis that bedside clinicians failed to recognize and treat in a timely manner.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The kappa statistic in reliability studies: use, interpretation, and sample size requirements
Sim, J., & Wright, C. C. (2005) · Physical Therapy · doi:10.1093/ptj/85.3.257 · Cited by 4,093 · cited 1×
“80).(26,27) However, agreement between the criterion standard and the first iteration of the sepsis sniffer (Algorithm 1) was not as good.”
BackgroundA randomized trial of protocol-based care for early septic shock.
The ProCESS Investigators (2014) · New England Journal of Medicine · doi:10.1056/nejmoa1401602 · Cited by 2,414
Ferrer, R. (2008) · JAMA · doi:10.1001/jama.299.19.2294 · Cited by 741
Implementation of a real-time computerized sepsis alert in nonintensive care unit patients*
Sawyer, A. M., Deal, E. N., Labelle, A. J., Witt, C., Thiel, S. W., Heard, K., Reichley, R. M., Micek, S. T., & Kollef, M. H. (2011) · Critical Care Medicine · doi:10.1097/ccm.0b013e318205df85 · Cited by 169
Prospective Trial of Real-Time Electronic Surveillance to Expedite Early Care of Severe Sepsis
Nelson, J. L., Smith, B. L., Jared, J. D., & Younger, J. G. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.12.008 · Cited by 122
Hooper, M. H., Weavind, L., Wheeler, A. P., Martin, J. B., Gowda, S. S., Semler, M. W., Hayes, R. M., Albert, D. W., Deane, N. B., Nian, H., et al. (2012) · Critical Care Medicine · doi:10.1097/ccm.0b013e318250a887 · Cited by 121
Cited by
Burdick, H., Pino, E., Gabel-Comeau, D., McCoy, A., Gu, C., Roberts, J., Le, S., Slote, J., Pellegrini, E., Green-Saxena, A., et al. (2020) · BMJ Health & Care Informatics · doi:10.1136/bmjhci-2019-100109 · Cited by 80
van der Vegt, A. H., Scott, I. A., Dermawan, K., Schnetler, R. J., Kalke, V. R., & Lane, P. J. (2023) · Journal of the American Medical Informatics Association · doi:10.1093/jamia/ocad075 · Cited by 72
Development and Implementation of Sepsis Alert Systems
Harrison, A. M., Gajic, O., Pickering, B. W., & Herasevich, V. (2016) · Clinics in Chest Medicine · doi:10.1016/j.ccm.2016.01.004 · Cited by 46
Self-citation21st Century critical care medicine: an overview
Padte, S., Samala Venkata, V., Mehta, P., Tawfeeq, S., Kashyap, R., & Surani, S. (2024) · World Journal of Critical Care Medicine · doi:10.5492/wjccm.v13.i1.90176 · Cited by 26
“Earlier detection via sepsis surveillance algorithm has been a pioneering advancement in the 21 st century[50].”
Self-citationBenthin, C., Pannu, S., Khan, A., & Gong, M. (2016) · Annals of the American Thoracic Society · doi:10.1513/annalsats.201603-172bc · Cited by 18
Metadata
- Authors
- Harrison, A. M., Thongprayoon, C., Kashyap, R., Chute, C. G., Gajic, O., Pickering, B. W., & Herasevich, V.
- Venue
- Mayo Clinic Proceedings
- Publisher
- Elsevier BV
- Published
- 2015-02
- Volume
- 90
- Issue
- 2
- Pages
- 166-175
- ISSN
- 0025-6196 (ISSN-L)
- OpenAlex
- W2041828980
- Cited by
- 59
- References
- 6
- FWCI
- 4.82
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Developing the Surveillance Algorithm for Detection of Failure to Recognize and Treat Severe Sepsis. https://app.cochat.ai/papers/10.1016/j.mayocp.2014.11.014
- The paper
- Harrison, A. M., Thongprayoon, C., Kashyap, R., Chute, C. G., Gajic, O., Pickering, B. W., & Herasevich, V. (2015). Developing the Surveillance Algorithm for Detection of Failure to Recognize and Treat Severe Sepsis. Mayo Clinic Proceedings. https://doi.org/10.1016/j.mayocp.2014.11.014
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.