CoChat

Developing the Surveillance Algorithm for Detection of Failure to Recognize and Treat Severe Sepsis

Open access
Harrison, Andrew M., Thongprayoon, Charat, Kashyap, Rahul, Chute, Christopher G., Gajic, Ognjen, Pickering, Brian W., Herasevich, Vitaly · 2015 · Mayo Clinic Proceedings
Cited by 59

The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.

Abstract

Objective: To develop and test an automated surveillance algorithm (sepsis “sniffer”) for the detection of severe sepsis and monitoring failure to recognize and treat severe sepsis in a timely manner. Patients and Methods: We conducted an observational diagnostic performance study using independent derivation and validation cohorts from an electronic medical record database of the medical intensive care unit (ICU) of a tertiary referral center. All patients aged 18 years and older who were admitted to the medical ICU from January 1 through March 31, 2013 (N=587), were included. The criterion standard for severe sepsis/septic shock was manual review by 2 trained reviewers with a third superreviewer for cases of interobserver disagreement. Critical appraisal of false-positive and false-negative alerts, along with recursive data partitioning, was performed for algorithm optimization. Results: An algorithm based on criteria for suspicion of infection, systemic inflammatory response syndrome, organ hypoperfusion and dysfunction, and shock had a sensitivity of 80% and a specificity of 96% when applied to the validation cohort. In order, low systolic blood pressure, systemic inflammatory response syndrome positivity, and suspicion of infection were determined through recursive data partitioning to be of greatest predictive value. Lastly, 117 alert-positive patients (68% of the 171 patients with severe sepsis) had a delay in recognition and treatment, defined as no lactate and central venous pressure measurement within 2 hours of the alert. Conclusion: The optimized sniffer accurately identified patients with severe sepsis that bedside clinicians failed to recognize and treat in a timely manner.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1016/j.mayocp.2014.11.014

Cites

6 of 6 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 6 references

Cited by

See all 59

Metadata

Authors
Harrison, A. M., Thongprayoon, C., Kashyap, R., Chute, C. G., Gajic, O., Pickering, B. W., & Herasevich, V.
Venue
Mayo Clinic Proceedings
Publisher
Elsevier BV
Published
2015-02
Volume
90
Issue
2
Pages
166-175
ISSN
0025-6196 (ISSN-L)
OpenAlex
W2041828980
Cited by
59
References
6
FWCI
4.82
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Developing the Surveillance Algorithm for Detection of Failure to Recognize and Treat Severe Sepsis. https://app.cochat.ai/papers/10.1016/j.mayocp.2014.11.014
The paper
Harrison, A. M., Thongprayoon, C., Kashyap, R., Chute, C. G., Gajic, O., Pickering, B. W., & Herasevich, V. (2015). Developing the Surveillance Algorithm for Detection of Failure to Recognize and Treat Severe Sepsis. Mayo Clinic Proceedings. https://doi.org/10.1016/j.mayocp.2014.11.014

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.