The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Trapped Ion Mobility Spectrometry and Parallel Accumulation–Serial Fragmentation in Proteomics
Open accessAbstract
Recent advances in efficiency and ease of implementation have rekindled interest in ion mobility spectrometry, a technique that separates gas phase ions by their size and shape and that can be hybridized with conventional LC and MS. Here, we review the recent development of trapped ion mobility spectrometry (TIMS) coupled to TOF mass analysis. In particular, the parallel accumulation-serial fragmentation (PASEF) operation mode offers unique advantages in terms of sequencing speed and sensitivity. Its defining feature is that it synchronizes the release of ions from the TIMS device with the downstream selection of precursors for fragmentation in a TIMS quadrupole TOF configuration. As ions are compressed into narrow ion mobility peaks, the number of peptide fragment ion spectra obtained in data-dependent or targeted analyses can be increased by an order of magnitude without compromising sensitivity. Taking advantage of the correlation between ion mobility and mass, the PASEF principle also multiplies the efficiency of data-independent acquisition. This makes the technology well suited for rapid proteome profiling, an increasingly important attribute in clinical proteomics, as well as for ultrasensitive measurements down to single cells. The speed and accuracy of TIMS and PASEF also enable precise measurements of collisional cross section values at the scale of more than a million data points and the development of neural networks capable of predicting them based only on peptide sequences. Peptide collisional cross section values can differ for isobaric sequences or positional isomers of post-translational modifications. This additional information may be leveraged in real time to direct data acquisition or in postprocessing to increase confidence in peptide identifications. These developments make TIMS quadrupole TOF PASEF a powerful and expandable platform for proteomics and beyond.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Highly accurate protein structure prediction with AlphaFold
Jumper, J., Evans, R., Pritzel, A., Green, T., Figurnov, M., Ronneberger, O., Tunyasuvunakool, K., Bates, R., Žídek, A., Potapenko, A., et al. (2021) · Nature · doi:10.1038/s41586-021-03819-2 · Cited by 43,764
Cox, J., & Mann, M. (2008) · Nature Biotechnology · doi:10.1038/nbt.1511 · Cited by 14,855
Self-citationGillet, L. C., Navarro, P., Tate, S., Röst, H., Selevsek, N., Reiter, L., Bonner, R., & Aebersold, R. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o111.016717 · Cited by 2,877
Mass-spectrometric exploration of proteome structure and function
Aebersold, R., & Mann, M. (2016) · Nature · doi:10.1038/nature19949 · Cited by 2,334
Self-citationSelected reaction monitoring–based proteomics: workflows, potential, pitfalls and future directions
Picotti, P., & Aebersold, R. (2012) · Nature Methods · doi:10.1038/nmeth.2015 · Cited by 1,302
Peterson, A. C., Russell, J. D., Bailey, D. J., Westphall, M. S., & Coon, J. J. (2012) · Molecular & Cellular Proteomics · doi:10.1074/mcp.o112.020131 · Cited by 1,288
Bruderer, R., Bernhardt, O. M., Gandhi, T., Miladinović, S. M., Cheng, L.-Y., Messner, S., Ehrenberger, T., Zanotelli, V., Butscheid, Y., Escher, C., et al. (2015) · Molecular & Cellular Proteomics · doi:10.1074/mcp.m114.044305 · Cited by 1,238
Michalski, A., Cox, J., & Mann, M. (2011) · Journal of Proteome Research · doi:10.1021/pr101060v · Cited by 685
Self-citationOpenCell: Endogenous tagging for the cartography of human cellular organization
Cho, N. H., Cheveralls, K. C., Brunner, A.-D., Kim, K., Michaelis, A. C., Raghavan, P., Kobayashi, H., Savy, L., Li, J. Y., Canaj, H., et al. (2022) · Science · doi:10.1126/science.abi6983 · Cited by 567
Self-citationDeep Visual Proteomics defines single-cell identity and heterogeneity
Mund, A., Coscia, F., Kriston, A., Hollandi, R., Kovács, F., Brunner, A.-D., Migh, E., Schweizer, L., Santos, A., Bzorek, M., et al. (2022) · Nature Biotechnology · doi:10.1038/s41587-022-01302-5 · Cited by 562
Self-citationUltra‐high sensitivity mass spectrometry quantifies single‐cell proteome changes upon perturbation
Brunner, A., Thielert, M., Vasilopoulou, C., Ammar, C., Coscia, F., Mund, A., Hoerning, O. B., Bache, N., Apalategui, A., Lubeck, M., et al. (2022) · Molecular Systems Biology · doi:10.15252/msb.202110798 · Cited by 544
Self-citationRecommendations for reporting ion mobility Mass Spectrometry measurements
Gabelica, V., Shvartsburg, A. A., Afonso, C., Barran, P., Benesch, J. L. P., Bleiholder, C., Bowers, M. T., Bilbao, A., Bush, M. F., Campbell, J. L., et al. (2019) · Mass Spectrometry Reviews · doi:10.1002/mas.21585 · Cited by 493
Research works printed but not linked: 101
- Adhikari, 2020, A high-stringency blueprint of the human proteome, Nat. Commun., 11, 5301, 10.1038/s41467-020-19045-9 · DOI · Paper page
- Müller, 2020, The proteome landscape of the kingdoms of life, Nature, 582, 592, 10.1038/s41586-020-2402-x · DOI · Paper page
- Shishkova, 2016, Now, more than ever, proteomics needs better chromatography, Cell Syst., 3, 321, 10.1016/j.cels.2016.10.007 · DOI
- Bekker-Jensen, 2017, An optimized shotgun strategy for the rapid generation of comprehensive human proteomes, Cell Syst., 4, 587, 10.1016/j.cels.2017.05.009 · DOI · Paper page
- Meier, 2018, BoxCar acquisition method enables single-shot proteomics at a depth of 10,000 proteins in 100 minutes, Nat. Methods, 15, 440, 10.1038/s41592-018-0003-5 · DOI · Paper page
- Muntel, 2019, Surpassing 10 000 identified and quantified proteins in a single run by optimizing current LC-MS instrumentation and data analysis strategy, Mol. Omics, 15, 348, 10.1039/C9MO00082H · DOI · Paper page
- Kanu, 2008, Ion mobility-mass spectrometry, J. Mass Spectrom., 43, 1, 10.1002/jms.1383 · DOI · Paper page
- May, 2015, Ion mobility-mass spectrometry: Time-dispersive instrumentation, Anal. Chem., 87, 1422, 10.1021/ac504720m · DOI · Paper page
- Dodds, 2019, Ion mobility spectrometry: Fundamental concepts, instrumentation, applications, and the road ahead, J. Am. Soc. Mass Spectrom., 30, 2185, 10.1007/s13361-019-02288-2 · DOI · Paper page
- Giles, 2004, Applications of a travelling wave-based radio-frequency-only stacked ring ion guide, Rapid Commun. Mass Spectrom., 18, 2401, 10.1002/rcm.1641 · DOI · Paper page
- Shvartsburg, 2008, Fundamentals of traveling wave ion mobility spectrometry, Anal. Chem., 80, 9689, 10.1021/ac8016295 · DOI · Paper page
- Buryakov, 1993, A new method of separation of multi-atomic ions by mobility at atmospheric pressure using a high-frequency amplitude-asymmetric strong electric field, Int. J. Mass Spectrom. Ion Process., 128, 143, 10.1016/0168-1176(93)87062-W · DOI · Paper page
- Guevremont, 2004, High-field asymmetric waveform ion mobility spectrometry: A new tool for mass spectrometry, J. Chromatogr. A, 1058, 3, 10.1016/S0021-9673(04)01478-5 · doi:10.1016/s0021-9673(04)01478-5 · Paper page
- Venne, 2005, Improvement in peptide detection for proteomics analyses using nanoLC-MS and high-field asymmetry waveform ion mobility mass spectrometry, Anal. Chem., 77, 2176, 10.1021/ac048410j · DOI
- Canterbury, 2008, Assessing the dynamic range and peak capacity of nanoflow LC-FAIMS-MS on an ion trap mass spectrometer for proteomics, Anal. Chem., 80, 6888, 10.1021/ac8004988 · DOI
- Saba, 2009, Enhanced sensitivity in proteomics experiments using FAIMS coupled with a hybrid linear ion trap/orbitrap mass spectrometer, J. Proteome Res., 8, 3355, 10.1021/pr801106a · DOI
- Baker, 2010, An LC-IMS-MS platform providing increased dynamic range for high-throughput proteomic studies, J. Proteome Res., 9, 997, 10.1021/pr900888b · DOI
- Distler, 2014, Drift time-specific collision energies enable deep-coverage data-independent acquisition proteomics, Nat. Methods, 11, 167, 10.1038/nmeth.2767 · DOI · Paper page
- Helm, 2014, Ion mobility tandem mass spectrometry enhances performance of bottom-up proteomics, Mol. Cell. Proteomics, 13, 3709, 10.1074/mcp.M114.041038 · DOI
- Distler, 2014, Biomedical applications of ion mobility-enhanced data-independent acquisition-based label-free quantitative proteomics, Expert Rev. Proteomics, 11, 675, 10.1586/14789450.2014.971114 · DOI
- Pfammatter, 2018, A novel differential ion mobility device expands the depth of proteome coverage and the sensitivity of multiplex proteomic measurements, Mol. Cell. Proteomics, 17, 2051, 10.1074/mcp.TIR118.000862 · DOI
- Hebert, 2018, Comprehensive single-shot proteomics with FAIMS on a hybrid orbitrap mass spectrometer, Anal. Chem., 90, 9529, 10.1021/acs.analchem.8b02233 · DOI · Paper page
- Meier, 2018, Online parallel accumulation–serial fragmentation (PASEF) with a novel trapped ion mobility mass spectrometer, Mol. Cell. Proteomics, 17, 2534, 10.1074/mcp.TIR118.000900 · DOI · Paper page
- Bekker-Jensen, 2020, A compact quadrupole-orbitrap mass spectrometer with FAIMS interface improves proteome coverage in short LC gradients, Mol. Cell. Proteomics, 19, 716, 10.1074/mcp.TIR119.001906 · DOI · Paper page
- Meyer, 2020, Quantitative shotgun proteome analysis by direct infusion, Nat. Methods, 17, 1222, 10.1038/s41592-020-00999-z · DOI
- Fernandez-Lima, 2011, Gas-phase separation using a trapped ion mobility spectrometer, Int. J. Ion Mobil. Spectrom., 14, 93, 10.1007/s12127-011-0067-8 · DOI · Paper page
- Fernandez-Lima, 2011, Note: Integration of trapped ion mobility spectrometry with mass spectrometry, Rev. Sci. Instrum., 82, 126106, 10.1063/1.3665933 · DOI · Paper page
- Meier, 2015, Parallel accumulation–serial fragmentation (PASEF): Multiplying sequencing speed and sensitivity by synchronized scans in a trapped ion mobility device, J. Proteome Res., 14, 5378, 10.1021/acs.jproteome.5b00932 · DOI · Paper page
- Ridgeway, 2018, Trapped ion mobility spectrometry: A short review, Int. J. Mass Spectrom., 425, 22, 10.1016/j.ijms.2018.01.006 · DOI · Paper page
- Silveira, 2017, Parallel accumulation for 100% duty cycle trapped ion mobility-mass spectrometry, Int. J. Mass Spectrom., 413, 168, 10.1016/j.ijms.2016.03.004 · DOI
- Beck, 2015, The impact II, a very high-resolution quadrupole time-of-flight instrument (QTOF) for deep shotgun proteomics, Mol. Cell. Proteomics, 14, 2014, 10.1074/mcp.M114.047407 · DOI · Paper page
- Lesur, 2021, Highly multiplexed targeted proteomics acquisition on a TIMS-QTOF, Anal. Chem., 93, 1383, 10.1021/acs.analchem.0c03180 · DOI
- Meier, 2020, diaPASEF: Parallel accumulation–serial fragmentation combined with data-independent acquisition, Nat. Methods, 17, 1229, 10.1038/s41592-020-00998-0 · DOI · Paper page
- Michelmann, 2014, Fundamentals of trapped ion mobility spectrometry, J. Am. Soc. Mass Spectrom., 26, 14, 10.1007/s13361-014-0999-4 · DOI · Paper page
- Silveira, 2016, Fundamentals of trapped ion mobility spectrometry part II: Fluid dynamics, J. Am. Soc. Mass Spectrom., 27, 585, 10.1007/s13361-015-1310-z · DOI
- Bleiholder, 2016, Towards measuring ion mobilities in non-stationary gases and non-uniform and dynamic electric fields (I). Transport equation, Int. J. Mass Spectrom., 399-400, 1, 10.1016/j.ijms.2016.01.003 · DOI
- Silveira, 2016, Altering the mobility-time continuum: Nonlinear scan functions for targeted high resolution trapped ion mobility-mass spectrometry, Int. J. Ion Mobil. Spectrom., 19, 87, 10.1007/s12127-016-0196-1 · DOI
- Benigni, 2018, Increasing analytical separation and duty cycle with nonlinear analytical mobility scan functions in TIMS-FT-ICR MS, Anal. Chem., 90, 2446, 10.1021/acs.analchem.7b04053 · DOI
- Silveira, 2014, High resolution trapped ion mobility spectrometery of peptides, Anal. Chem., 86, 5624, 10.1021/ac501261h · DOI · Paper page
- Hernandez, 2014, Ion dynamics in a trapped ion mobility spectrometer, Analyst, 139, 1913, 10.1039/C3AN02174B · DOI · Paper page
- Ridgeway, 2015, Microheterogeneity within conformational states of ubiquitin revealed by high resolution trapped ion mobility spectrometry, Analyst, 140, 6964, 10.1039/C5AN00841G · DOI
- Adams, 2016, Isomer separation of polybrominated diphenyl ether metabolites using nanoESI-TIMS-MS, Int. J. Ion Mobil. Spectrom., 19, 69, 10.1007/s12127-016-0198-z · doi:10.1007/s12127-016-0198-z
- Liu, 2018, Tandem trapped ion mobility spectrometry, Analyst, 143, 2249, 10.1039/C7AN02054F · DOI
- Ridgeway, 2016, Gated trapped ion mobility spectrometry coupled to Fourier transform ion cyclotron resonance mass spectrometry, Int. J. Ion Mobil. Spectrom., 19, 77, 10.1007/s12127-016-0197-0 · DOI
- Liu, 2016, On the structural denaturation of biological analytes in trapped ion mobility spectrometry – mass spectrometry, Analyst, 141, 3722, 10.1039/C5AN02399H · DOI
- Bleiholder, 2019, Structure relaxation approximation (SRA) for elucidation of protein structures from ion mobility measurements, J. Phys. Chem. B, 123, 2756, 10.1021/acs.jpcb.8b11818 · DOI
- Molano-Arevalo, 2017, Characterization of intramolecular interactions of cytochrome C using hydrogen–deuterium exchange-trapped ion mobility spectrometry–mass spectrometry and molecular dynamics, Anal. Chem., 89, 8757, 10.1021/acs.analchem.7b00844 · DOI
- Fantin, 2019, Collision induced unfolding classifies ligands bound to the integral membrane translocator protein, Anal. Chem., 91, 15469, 10.1021/acs.analchem.9b03208 · DOI
- Naylor, 2020, Evaluation of trapped ion mobility spectrometry source conditions using benzylammonium thermometer ions, J. Am. Soc. Mass Spectrom., 31, 1593, 10.1021/jasms.0c00151 · DOI
- Morsa, 2020, Effective temperature and structural rearrangement in trapped ion mobility spectrometry, Anal. Chem., 92, 4573, 10.1021/acs.analchem.9b05850 · DOI
- Yu, 2020, Fast quantitative analysis of timsTOF PASEF data with MSFragger and IonQuant, Mol. Cell. Proteomics, 19, 1575, 10.1074/mcp.TIR120.002048 · DOI · Paper page
- Tolmachev, 2004, Collisional activation of ions in RF ion traps and ion guides: The effective ion temperature treatment, J. Am. Soc. Mass Spectrom., 15, 1616, 10.1016/j.jasms.2004.07.014 · doi:10.1016/j.jasms.2004.07.014
- Bleiholder, 2020, Comment on effective temperature and structural rearrangement in trapped ion mobility spectrometry: TIMS enables native mass spectrometry applications, Anal. Chem., 10.1021/acs.analchem.0c02052 · doi:10.1021/acs.analchem.0c02052
- Panczyk, 2021, Surface-induced dissociation of protein complexes selected by trapped ion mobility spectrometry, Anal. Chem., 93, 5513, 10.1021/acs.analchem.0c05373 · DOI
- Larson, 2021, High-throughput multi-attribute analysis of antibody-drug conjugates enabled by trapped ion mobility spectrometry and top-down mass spectrometry, Anal. Chem., 93, 10013, 10.1021/acs.analchem.1c00150 · DOI
- Borotto, 2021, Fragmentation and mobility separation of peptide and protein ions in a trapped-ion mobility device, Anal. Chem., 93, 9959, 10.1021/acs.analchem.1c01188 · DOI
- Ogata, 2020, Extending the separation space with trapped ion mobility spectrometry improves the accuracy of isobaric tag-based quantitation in proteomic LC/MS/MS, Anal. Chem., 92, 8037, 10.1021/acs.analchem.0c01695 · DOI
- Vasilopoulou, 2020, Trapped ion mobility spectrometry and PASEF enable in-depth lipidomics from minimal sample amounts, Nat. Commun., 11, 331, 10.1038/s41467-019-14044-x · DOI · Paper page
- Andrews, 2011, Performance characteristics of a new hybrid quadrupole time-of-flight tandem mass spectrometer (TripleTOF 5600), Anal. Chem., 83, 5442, 10.1021/ac200812d · DOI · Paper page
- Kelstrup, 2012, Optimized fast and sensitive acquisition methods for shotgun proteomics on a quadrupole orbitrap mass spectrometer, J. Proteome Res., 11, 3487, 10.1021/pr3000249 · DOI · Paper page
- Steigenberger, 2020, Benefits of collisional cross section assisted precursor selection (caps-PASEF) for cross-linking mass spectrometry, Mol. Cell. Proteomics, 19, 1677, 10.1074/mcp.RA120.002094 · DOI
- Bailey, 2012, Instant spectral assignment for advanced decision tree-driven mass spectrometry, Proc. Natl. Acad. Sci. U. S. A., 109, 8411, 10.1073/pnas.1205292109 · DOI
- Wichmann, 2019, MaxQuant.Live enables global targeting of more than 25,000 peptides, Mol. Cell. Proteomics, 18, 982, 10.1074/mcp.TIR118.001131 · DOI
- Schweppe, 2020, Full-featured, real-time database searching platform enables fast and accurate multiplexed quantitative proteomics, J. Proteome Res., 19, 2026, 10.1021/acs.jproteome.9b00860 · DOI · Paper page
- Moseley, 2018, Scanning quadrupole data-independent acquisition, part A: Qualitative and quantitative characterization, J. Proteome Res., 17, 770, 10.1021/acs.jproteome.7b00464 · DOI
- Juvvadi, 2018, Scanning quadrupole data-independent acquisition, part B: Application to the analysis of the calcineurin-interacting proteins during treatment of Aspergillus fumigatus with azole and echinocandin antifungal drugs, J. Proteome Res., 17, 780, 10.1021/acs.jproteome.7b00499 · DOI
- Messner, 2021, Ultra-fast proteomics with scanning SWATH, Nat. Biotechnol., 39, 846, 10.1038/s41587-021-00860-4 · DOI · Paper page
- Amodei, 2019, Improving precursor selectivity in data-independent acquisition using overlapping windows, J. Am. Soc. Mass Spectrom., 30, 669, 10.1007/s13361-018-2122-8 · DOI
- Prianichnikov, 2020, MaxQuant software for ion mobility enhanced shotgun proteomics, Mol. Cell. Proteomics, 19, 1058, 10.1074/mcp.TIR119.001720 · DOI · Paper page
- Kong, 2017, MSFragger: Ultrafast and comprehensive peptide identification in mass spectrometry–based proteomics, Nat. Methods, 14, 513, 10.1038/nmeth.4256 · DOI · Paper page
- Yu, 2021, IonQuant enables accurate and sensitive label-free quantification with FDR-controlled match-between-runs, Mol. Cell. Proteomics, 20, 100077, 10.1016/j.mcpro.2021.100077 · DOI · Paper page
- Zhang, 2012, PEAKS DB: De novo sequencing assisted database search for sensitive and accurate peptide identification, Mol. Cell. Proteomics, 11, 10.1074/mcp.M111.010587 · DOI · Paper page
- Willems, 2021, AlphaTims: Indexing trapped ion mobility spectrometry – time of flight data for fast and easy accession and visualization, bioRxiv
- Łącki, 2021, OpenTIMS, TimsPy, and TimsR: Open and easy access to timsTOF raw data, J. Proteome Res., 20, 2122, 10.1021/acs.jproteome.0c00962 · doi:10.1021/acs.jproteome.0c00962
- Strauss, 2021, AlphaPept, a modern and open framework for MS-based proteomics, bioRxiv
- Pino, 2020, The Skyline ecosystem: Informatics for quantitative mass spectrometry proteomics, Mass Spectrom. Rev., 39, 229, 10.1002/mas.21540 · DOI · Paper page
- Röst, 2014, OpenSWATH enables automated, targeted analysis of data-independent acquisition MS data, Nat. Biotechnol., 32, 219, 10.1038/nbt.2841 · DOI · Paper page
- Demichev, 2020, DIA-NN: Neural networks and interference correction enable deep proteome coverage in high throughput, Nat. Methods, 17, 41, 10.1038/s41592-019-0638-x · DOI · Paper page
- Demichev, 2021, High sensitivity dia-PASEF proteomics with DIA-NN and FragPipe, bioRxiv
- Sinitcyn, 2021, MaxDIA enables library-based and library-free data-independent acquisition proteomics, Nat. Biotechnol., 10.1038/s41587-021-00968-7 · DOI · Paper page
- Meier, 2021, Deep learning the collisional cross sections of the peptide universe from a million experimental values, Nat. Commun., 12, 1185, 10.1038/s41467-021-21352-8 · DOI
- Revercomb, 1975, Theory of plasma chromatography/gaseous electrophoresis. Review, Anal. Chem., 47, 970, 10.1021/ac60357a043 · DOI · Paper page
- Chai, 2018, A transferable, sample-independent calibration procedure for trapped ion mobility spectrometry (TIMS), Anal. Chem., 90, 9040, 10.1021/acs.analchem.8b01326 · DOI
- Chang, 2021, Sequence-specific model for predicting peptide collision cross section values in proteomic ion mobility spectrometry, J. Proteome Res., 20, 3600, 10.1021/acs.jproteome.1c00185 · DOI
- Counterman, 2002, Cis−trans signatures of proline-containing tryptic peptides in the gas phase, Anal. Chem., 74, 1946, 10.1021/ac011083k · doi:10.1021/ac011083k
- Pierson, 2011, Number of solution states of bradykinin from ion mobility and mass spectrometry measurements, J. Am. Chem. Soc., 133, 13810, 10.1021/ja203895j · DOI
- Bache, 2018, A novel LC system embeds analytes in pre-formed gradients for rapid, ultra-robust proteomics, Mol. Cell. Proteomics, 17, 2284, 10.1074/mcp.TIR118.000853 · DOI · Paper page
- Bian, 2020, Robust, reproducible and quantitative analysis of thousands of proteomes by micro-flow LC–MS/MS, Nat. Commun., 11, 157, 10.1038/s41467-019-13973-x · DOI · Paper page
- Zaro, 2020, Proteomic analysis of young and old mouse hematopoietic stem cells and their progenitors reveals post-transcriptional regulation in stem cells, Elife, 9, 10.7554/eLife.62210 · DOI
- Fu, 2020, Glucose-dependent partitioning of arginine to the urea cycle protects β-cells from inflammation, Nat. Metab., 2, 432, 10.1038/s42255-020-0199-4 · DOI
- Wu, 2020, Transcriptional and proteomic insights into the host response in fatal COVID-19 cases, Proc. Natl. Acad. Sci. U. S. A., 117, 28336, 10.1073/pnas.2018030117 · DOI · Paper page
- Geyer, 2021, High-resolution serum proteome trajectories in COVID-19 reveal patient-specific seroconversion, EMBO Mol. Med., 13, 10.15252/emmm.202114167 · DOI
- Tian, 2020, Immune suppression in the early stage of COVID-19 disease, Nat. Commun., 11, 5859, 10.1038/s41467-020-19706-9 · DOI · Paper page
- Jeanne Dit Fouque, 2021, Trapped ion mobility spectrometry of native macromolecular assemblies, Anal. Chem., 93, 2933, 10.1021/acs.analchem.0c04556 · DOI
- Alme, 2020, The kinase Isr1 negatively regulates hexosamine biosynthesis in S. cerevisiae, PLoS Genet., 16, 10.1371/journal.pgen.1008840 · DOI
- Glover, 2016, Examining the influence of phosphorylation on peptide ion structure by ion mobility spectrometry-mass spectrometry, J. Am. Soc. Mass Spectrom., 27, 786, 10.1007/s13361-016-1343-y · DOI
- Ogata, 2020, Effect of phosphorylation on the collision cross sections of peptide ions in ion mobility spectrometry, bioRxiv
- Ihling, 2021, Cross-linking/mass spectrometry combined with ion mobility on a timsTOF Pro instrument for structural proteomics, Anal. Chem., 93, 11442, 10.1021/acs.analchem.1c01317 · DOI
- Wen, 2020, Deep learning in proteomics, Proteomics, 20, 1900335, 10.1002/pmic.201900335 · DOI
- Tsugawa, 2020, A lipidome atlas in MS-DIAL 4, Nat. Biotechnol., 38, 1159, 10.1038/s41587-020-0531-2 · DOI · Paper page
- Nothias, 2020, Feature-based molecular networking in the GNPS analysis environment, Nat. Methods, 17, 905, 10.1038/s41592-020-0933-6 · DOI · Paper page
Cited by
Mass-spectrometry-based proteomics: from single cells to clinical applications
Guo, T., Steen, J. A., & Mann, M. (2025) · Nature · doi:10.1038/s41586-025-08584-0 · Cited by 320
Self-citationSkowronek, P., Thielert, M., Voytik, E., Tanzer, M. C., Hansen, F. M., Willems, S., Karayel, O., Brunner, A.-D., Meier, F., & Mann, M. (2022) · Molecular & Cellular Proteomics · doi:10.1016/j.mcpro.2022.100279 · Cited by 281
Self-citationSkowronek, P., Wallmann, G., Wahle, M., Willems, S., & Mann, M. (2025) · Nature Protocols · doi:10.1038/s41596-024-01104-w · Cited by 43
Self-citationXian, F., Sondermann, J. R., Gomez Varela, D., & Schmidt, M. (2022) · eLife · doi:10.7554/elife.81431 · Cited by 13
Metadata
- Authors
- Meier, F., Park, M. A., & Mann, M.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2021
- Volume
- 20
- Pages
- 100138
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W3195015580
- Cited by
- 183
- References
- 12
- FWCI
- 9.06
- Type
- journal article
- Language
- en
- Open access
- gold
- Licence
- www.elsevier.com/tdm/userlicense/1.0/ (tdm)
- www.elsevier.com/legal/tdmrep-license (tdm)
- creativecommons.org/licenses/by/4.0/ (vor, 225 d)
- Funders
- Max-Planck-Gesellschaft
- German Research Foundation (MA 1764/2-1)
- Bundesministerium für Bildung und Forschung
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.