Cited by 15ECG Monitoring and AnalysisNon-Invasive Vital Sign MonitoringWireless Body Area Networks

Real time system on chip based wearable cardiac activity monitoring sensor

Open access
Jain, Aryan, Singh, Mandeep, Singh, Balwinder·2022·Measurement: Sensors

Abstract

In this research, a real time low power wearable cardiac activity monitoring device is introduced to display real time electrocardiography (ECG) signal and heart rate (HR). ECG records heart’s electrical activity and heart rate measures the contraction of the heart. The developed device consumes very less power as SoC used in this research has power consumption of 85 μW at 1.1V supply voltage. To measure heart rate and ECG waveform, the pre-gelled ECG electrodes are attached on the RA, LA and LL positon of the human’s body. These pre-gelled ECG electrodes attached to the ECG lead which is further connected to the ECG device. The ECG system is validated and the measured average HR of the subject was 71 to 82 beats per minute (BPM) and ECG graph was also plotted.

Integrity signals

Registry

Crossref · 10.1016/j.measen.2022.100523

Cites

23 of 23 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Claims the paper makes

We couldn’t retrieve this paper’s full text, so its claims and self-check weren’t run. The registry and citation checks still apply.

Claims other papers make about this one

Each is checked against this paper’s own text: does it say what the citing paper says it does?

Cites

Flagged first, then by citations

2 of the 25 references couldn’t be matched to a known paper.

Cited by

Sorted by citations

Authors
Jain, A., Singh, M., & Singh, B.
Affiliations
Centre for Development of Advanced Computing (IN)
Corresponding author
Singh, Mandeep
Venue
Measurement: Sensors
Publisher
Elsevier BV
Published
2022-12
Volume
24
Pages
100523
ISSN
2665-9174 (ISSN-L)
OpenAlex
W4306252863
Cited by
15
References
25
Citations by year
2026: 4 · 2025: 3 · 2024: 6 · 2023: 2
FWCI
1.93
Type
journal article
Language
en
Open access
Locations
  • Measurement Sensors (publishedVersion, cc-by-nc-nd)
  • DOAJ (DOAJ: Directory of Open Access Journals) (submittedVersion, cc-by-sa)
Topics
  • Health Sciences › Medicine › Cardiology and Cardiovascular Medicine › ECG Monitoring and Analysis
  • Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
  • Physical Sciences › Engineering › Biomedical Engineering › Wireless Body Area Networks
Keywords
wearable cardiac monitoring, electrocardiogram, heart rate monitoring, system-on-chip, low-power sensors, ECG leads, cardiac implantable electronic devices

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review