CoChat

A 0.20 $\text {mm}^2$ 3 nW Signal Acquisition IC for Miniature Sensor Nodes in 65 nm CMOS

Open access
Harpe, Pieter, Gao, Hao, Dommele, Rainier van, Cantatore, Eugenio, van Roermund, Arthur H. M. · 2016 · IEEE Journal of Solid-State Circuits

The DOI matches its Crossref record; 17 of the 22 references it cites were found in a registry or an index.

Abstract

Miniature mm3-sized sensor nodes have a very tight power budget, in particular, when a long operational lifetime is required, which is the case, e.g., for implantable devices or unobtrusive IoT nodes. This paper presents a fully integrated signal acquisition IC for these emerging applications. It integrates an amplifier with 32 dB gain and 370 Hz bandwidth that includes positive feedback to enhance input impedance and dc offset compensation. The IC includes also a 10 bit 1 kS/s SAR ADC as well as a clock generator and voltage and current biasing circuits. The overall system achieves an input noise of 27 μVrms, consumes 3 nW from a 0.6 V supply, occupies 0.20 mm2in 65 nm CMOS, and has a single-wire data interface. The amplifier achieves an noise-efficiency factor (NEF) of 2.1 and the ADC has a figure-of-merit (FoM) of 1.5 fJ/conversion-step. Measurements confirm reliable operation for supplies from 0.50 to 0.70 V and temperatures in the range of 0-85 °C. As an application example, an ECG recording is successfully performed with the system while a 0.69 mm2photodiode array provides its power supply in indoor lighting conditions.

Overview

Integrity signals

Registry

Crossref · 10.1109/jssc.2015.2487270

Cites

17 of 17 references verified0 citation errors · 0 not checkable

Statistics

Recomputing p-values needs the paper’s full text.

Verification

Claims the paper makes

The text we found for this paper looks like another document, so its claims and self-check weren’t run. The registry and citation checks still apply.

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The text we found for this paper looks like another document, so the self-check wasn’t run.

Citations

Cites

Show all 17 references

Research works printed but not linked: 4

  1. van elzakker, 2008, A 1.9 $\upmu$W 4.4 fJ/conversion-step 10b 1 MS/s charge-redistribution ADC, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 244
  2. tai, 2014, A 0.85 fJ/conversion-step 10b 200 kS/s subranging SAR ADC in 40 nm CMOS, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 196
  3. yan, 2014, A 680 nA fully integrated implantable ECG acquisition IC with analog feature extraction, IEEE Int Solid-State Circuits Conf (ISSCC) Dig Tech Papers, 418
  4. murmann, 2015, ADC Performance Survey 1997–2013

Cited by

See all 124

Metadata

Authors
Harpe, P., Gao, H., Dommele, R. V., Cantatore, E., & van Roermund, A. H. M.
Affiliations
Eindhoven University of Technology (NL)
Venue
IEEE Journal of Solid-State Circuits
Published
2016-01
Volume
51
Issue
1
Pages
240-248
ISSN
  • 0018-9200 (ISSN-L)
  • 1558-173X
OpenAlex
W2211705316
Cited by
124
References
22
Citations by year
2026: 4 · 2025: 12 · 2024: 13 · 2023: 8 · 2022: 10 · 2021: 19 · 2020: 10 · 2019: 19 · 2018: 11 · 2017: 16 · 2016: 1
FWCI
4.64
Type
journal article
Language
en
Open access
Locations
  • IEEE Journal of Solid-State Circuits (publishedVersion)
  • TU/e Research Portal (publishedVersion, other-oa)
  • TU/e Research Portal (submittedVersion, other-oa)
  • TU/e Research Portal (submittedVersion)
Funders
Stichting voor de Technische Wetenschappen
Topics
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Analog and Mixed-Signal Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Radio Frequency Integrated Circuit Design
  • Physical Sciences › Engineering › Electrical and Electronic Engineering › Low-power high-performance VLSI design
Keywords
biomedical implants, Internet of Things, low-power amplifier, positive feedback, DC offset compensation, input impedance, successive approximation register ADC, clock generator, bias circuit, noise efficiency factor, figure of merit, ECG recording, 65 nm CMOS

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: A 0.20 $\text {mm}^2$ 3 nW Signal Acquisition IC for Miniature Sensor Nodes in 65 nm CMOS. https://app.cochat.ai/papers/10.1109/jssc.2015.2487270
The paper
Harpe, P., Gao, H., Dommele, R. V., Cantatore, E., & van Roermund, A. H. M. (2016). A 0.20 $\text {mm}^2$ 3 nW Signal Acquisition IC for Miniature Sensor Nodes in 65 nm CMOS. IEEE Journal of Solid-State Circuits. https://doi.org/10.1109/jssc.2015.2487270

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.