Instrumenting gait with an accelerometer: A system and algorithm examination
Open accessThe DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Abstract
Detailed investigation to explain poor variability/asymmetry agreement between accelerometers and instrumented walkway. Caution is urged in the choice of reference system for validation studies. Accelerometers have potential to gather continuous and robust spatio-temporal gait data, representative of normal living. Further refinement of the gait algorithms are required. Gait is an important clinical assessment tool since changes in gait may reflect changes in general health. Measurement of gait is a complex process which has been restricted to the laboratory until relatively recently. The application of an inexpensive body worn sensor with appropriate gait algorithms (BWM) is an attractive alternative and offers the potential to assess gait in any setting. In this study we investigated the use of a low-cost BWM, compared to laboratory reference using a robust testing protocol in both younger and older adults. We observed that the BWM is a valid tool for estimating total step count and mean spatio-temporal gait characteristics however agreement for variability and asymmetry results was poor. We conducted a detailed investigation to explain the poor agreement between systems and determined it was due to inherent differences between the systems rather than inability of the sensor to measure the gait characteristics. The results highlight caution in the choice of reference system for validation studies. The BWM used in this study has the potential to gather longitudinal (real-world) spatio-temporal gait data that could be readily used in large lifestyle-based intervention studies, but further refinement of the algorithm(s) is required.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Gait speed and survival in older adults.
Studenski, S. (2011) · JAMA · doi:10.1001/jama.2010.1923 · Cited by 4,558
When to use the Bonferroni correction
Armstrong, R. A. (2014) · Ophthalmic and Physiological Optics · doi:10.1111/opo.12131 · Cited by 3,031 · cited 1×
“No Bonferroni correction was used due to the small number of comparisons (done per gait characteristic) between two groups (YHP/OHP or BWM/laboratory reference) [31].”
MethodDirect measurement of human movement by accelerometry
Godfrey, A., Conway, R., Meagher, D., & ÓLaighin, G. (2008) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2008.09.005 · Cited by 591
Self-citationISway: a sensitive, valid and reliable measure of postural control
Mancini, M., Salarian, A., Carlson-Kuhta, P., Zampieri, C., King, L., Chiari, L., & Horak, F. B. (2012) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/1743-0003-9-59 · Cited by 499 · cited 1×
“years [6, 9-12].”
Esser, P., Dawes, H., Collett, J., Feltham, M. G., & Howells, K. (2012) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2012.01.005 · Cited by 67
Cited by
Goldsack, J. C., Coravos, A., Bakker, J. P., Bent, B., Dowling, A. V., Fitzer-Attas, C., Godfrey, A., Godino, J. G., Gujar, N., Izmailova, E., et al. (2020) · npj Digital Medicine · doi:10.1038/s41746-020-0260-4 · Cited by 557
Self-citationDel Din, S., Godfrey, A., & Rochester, L. (2016) · IEEE Journal of Biomedical and Health Informatics · doi:10.1109/jbhi.2015.2419317 · Cited by 363
Self-citationDel Din, S., Godfrey, A., Galna, B., Lord, S., & Rochester, L. (2016) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-016-0154-5 · Cited by 349
Self-citationKobsar, D., Charlton, J. M., Tse, C. T. F., Esculier, J.-F., Graffos, A., Krowchuk, N. M., Thatcher, D., & Hunt, M. A. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00685-3 · Cited by 305
Use of wearable sensor technology in gait, balance, and range of motion analysis
Díaz, S., Stephenson, J. B., & Labrador, M. A. (2019) · Applied Sciences · doi:10.3390/app10010234 · Cited by 132
Celik, Y., Stuart, S., Woo, W., Sejdic, E., & Godfrey, A. (2022) · Information Fusion · doi:10.1016/j.inffus.2021.09.016 · Cited by 83
Self-citationCreagh, A. P., Hamy, V., Yuan, H., Mertes, G., Tomlinson, R., Chen, W.-H., Williams, R., Llop, C., Yee, C., Duh, M. S., et al. (2024) · npj Digital Medicine · doi:10.1038/s41746-024-01013-y · Cited by 64
Creagh, A. P., Hamy, V., Yuan, H., Mertes, G., Tomlinson, R., Chen, W.-H., Williams, R., Llop, C., Yee, C., Duh, M. S., et al. (2022) · doi:10.1101/2022.11.18.22282305 · Cited by 64
Metadata
- Authors
- Godfrey, A., Del Din, S., Barry, G., Mathers, J. C., & Rochester, L.
- Venue
- Medical Engineering & Physics
- Publisher
- IOP Publishing
- Published
- 2015-03-04
- Volume
- 37
- Issue
- 4
- Pages
- 400-407
- ISSN
- 1350-4533 (ISSN-L)
- 1873-4030
- OpenAlex
- W2149115530
- Cited by
- 213
- References
- 5
- FWCI
- 41.38
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.